HIGH TEMPERATURE CUT-OFF SWITCH

The thermostat has a built-in temperature cut-off switch (TCO), which
will shut off gas to the burner in case of excessive water temperature.
If the TCO functions the valve will flash 4 times and the valve must be
replaced.  It is important that a serviceman be called to determine the
reason for limit operation and thus avoid repeated thermostat resetting.
Lower the temperature adjustment dial setting on control.

VENTING SYSTEM

HAVE VENTING SYSTEM CHECKED EVERY SIX MONTHS FOR
OBSTRUCTIONS AND/OR DETERIORATION IN VENT PIPING.

A. Insofar as is practical, close all doors, windows and air inlets to the

building.  Turn on all exhaust fans (range hood, bathroom exhaust,
etc.) so they will operate at their maximum speed.  Close fireplace
dampers.

B. Turn water temperature adjusting knob to full, counterclockwise and

open water faucet if necessary to keep burner in operation.

C. “CHECKING THE DRAFT.”  Operate the water heater for several

minutes and check to see if it is venting properly by passing a lit
match or paper near the opening of the Air Supply Box.  If the draft is
proper, the match flame will be drawn into the Air Supply Box (fig
11).  If not, the combustion products will tend to extinguish the flame.
If an improper draft exists, do not operate the water heater until proper
adjustments or repairs are made to provide adequate draft through
the gas vent.

D. Next, turn on all other fuel burning appliances within the same room

so they will operate at their full input.

Repeat step C above.

 

FIGURE 11

    POWER VENTER MAINTENANCE

The BTF-75  must be inspected quarterly.  Points of inspection are:

1. MOTOR - Motor must rotate freely.  This is a sealed motor and no

oiling is required.

2. WHEEL - Wheel must be clean of soot, ash or any other coating

which inhibits either rotation or air flow.  Remove all foreign material
from vent system before operating.

3. AIR SUPPLY BOX-Every month check operation and make sure nothing

is blocking dilution air entrance.

4. The pressure switch part inside the power venter must be open and

free from deposits of soot, carbon, etc.

For safety and satisfactory operation it is recommended that the heater
be checked once a year by a competent service person.

 T & P VALVE

At least once a year, the temperature and pressure relief valve must be
checked to ensure that it is in operating condition.  Lift the lever at the
top of the valve several times until the valve seats properly and operates
freely.

  WARNING

THE WATER PASSING OUT OF THE VALVE DURING THIS CHECKING
OPERATION MAY BE EXTREMELY HOT.  AVOID CONTACT AND
DISCHARGE SAFELY TO PREVENT WATER DAMAGE.

DRAINING

Periodically open the drain valve and allow the water to run until it flows
clean.  This will help prevent sediment build-up in the tank.

It is normal for lime and scale deposits to form within the tank and on the
heat exchanger surfaces.  Such deposits will not be removed by periodic
draining.  It is necessary to chemically delime the affected parts in water
areas where such deposits are encountered.  Contact your dealer or
plumber for deliming information.

If the heater is to be shut off and exposed to freezing temperatures, it
must be drained.  Water, if left in the tank and allowed to freeze, will
damage the heater.

• Turn off the gas and cold water inlet valve to the heater.

• Open a nearby hot water faucet and the heater drain valve.

BE CAREFUL TO GRASP THE DRAIN VALVE HANDLE SO THAT THE
HAND IS NOT EXPOSED TO HOT WATER.  IF DESIRED, A HOSE MAY
BE CONNECTED TO THE DRAIN VALVE TO CARRY THE WATER
AWAY.

 

  WARNING:  The water CAN BE HOT.

The drain valve must be left open during the shutdown period.

• To restart heater, refer to the instructions under OPERATION.

MAIN BURNER AND IGNITER

Check main burner (figure 12) at least every 6 months for proper flame
characteristics.  The main burner should display the following
characteristics:

1. Provide complete combustion of gas.

2. Cause rapid ignition and carryover of flame across entire burner.

3. Give reasonably quiet operation during ignition, burning and extinction.

4. Cause no excessive lifting of flames from burner ports.

If preceding burner characteristics are not evident, check for
accumulation of lint or other foreign material that restricts or blocks the
air openings to the heater or burner.

  WARNING

SOOT BUILD-UP INDICATES A PROBLEM THAT REQUIRES CORRECTION
BEFORE FURTHER USE.  CONSULT WITH A QUALIFIED SERVICE
TECHNICIAN.

Содержание BTF-75

Страница 1: ...Y BEFORE INSTALLING AND USING THIS APPLIANCE A DIVISION OF A O SMITH CORPORATION McBee South Carolina U S A Stratford Ontario Canada www hotwater com KEEP THIS MANUAL IN THE POCKET ON THE HEATER FOR F...

Страница 2: ...tions and the local code authority having jurisdiction In the absence of local codes the installation must comply with the latest editions of the National Fuel Gas Code ANSI Z223 1 NFPA 54 The NFPA Th...

Страница 3: ...ral gas models A natural gas heater will not function safely on LP gas and no attempt should be made to convert a heater from natural gas to LP gas LP gas must be used with great caution It is highly...

Страница 4: ...in before operating Please refer to manufacturer s instructions DISHWASHING MACHINE REQUIREMENT These appliances meet the National Sanitation Foundation Standard for sanitary installations when used w...

Страница 5: ...60 75 percent for metal grills or louvers UNCONFINED SPACE In buildings of conventional frame brick or stone construction unconfined spaces may provide adequate air for combustion ventilation and dil...

Страница 6: ...TINGMUSTBEFOLLOWED TOAVOIDCHOKEDCOMBUSTIONORRECIRCULATIONOFFLUEGASES SUCH CONDITIONS CAUSE SOOTING OR RISKS OF FIRE AND ASPHYXIATION NEVEROPERATETHEHEATERUNLESSITISVENTED TOTHEOUTDOORSANDHASADEQUATEAI...

Страница 7: ...ceed the thirty 30 equivalent feet of 3 inch pipe or eighty five 85 equivalent feet of 4 inch pipe 3 The blower discharge adapter is made to accept only straight sections of 3 pipe To start a minimum...

Страница 8: ...ow be positioned on the outside wall using the drilled hole as a centering point for the template 3 A MASONRYSIDEWALLS Chisel an opening approximately one half inch larger than the marked circle B WOO...

Страница 9: ...tions are not reversed when making these connections See Figure 7 G Replace side panel and secure with two screws 5 The blower discharge adapter is made to accept only straight sections of 3 pipe To s...

Страница 10: ...run All piping and fittings must be joined by the proper procedures as described under VENTPIPEPREPARATION IMPORTANT The vent system must terminate so that proper clearances are maintained as cited i...

Страница 11: ...f the joint Tapered fitting sockets are designed so that an interference fit should occur when the pipe is inserted about 1 3 to 2 3 of the way into the socket Occasionally when pipe fitting dimension...

Страница 12: ...e sparingly and only to the male threads of pipe joints Do not apply compound to the first two threads Use compounds resistant to the action of liquefied petroleum gases Do not use teflon tape on ther...

Страница 13: ...ly counterclockwise until it stops 4 This appliance is equipped with a device which automatically lights the burner DONOTTRYTOLIGHTTHEBURNERBYHAND 5 Wait five 5 minutes to clear out any gas If you the...

Страница 14: ...atures produced at various thermostat dial settings Short repeated heating cycles caused by small hot water uses can cause temperatures at the point of use to exceed the thermostat setting by up to 20...

Страница 15: ...n etc For safety and satisfactory operation it is recommended that the heater be checked once a year by a competent service person T P VALVE At least once a year the temperature and pressure relief va...

Страница 16: ...e service you received First please contact your dealer or the A O Smith authorized service agent in your area and explain to them why you are not satisfied This will usually correct the problem If af...

Страница 17: ...ch Replace control harness Replace blower and motor Replace switch Check for low voltage less than 102 vac have service checked and repaired If voltage is above 102 vac make sure there is not more tha...

Страница 18: ...connectors 3 System wiring harness in good condition and securely connected at both ends Not Applicable 1 Replace control 1 Airflow proving switch stuck closed 2 Airflow proving switch mis wired or ju...

Страница 19: ...E AT HSI ELEMENT OUTPUT SEE INSET B 120V NOMINAL CHECK DAMAGED OR BROKEN HSI ELEMENT WARNING Line Voltage Hazard Can cause property damage severe injury or death Only a trained experienced service tec...

Страница 20: ...all other costs Such costs may include but are not limited to a Labor charges for service removal repair or reinstallation of the water heater or any component part b Shipping delivery handling and a...

Отзывы: