Code and description
Cause
Measure
S02 (blocking error)
Open circuit from sensor 1
of temperature sensor T
1
at the top of tank
(1).
Sensor is not (correctly) connected
Connect the sensor lead to JP5
Damaged cable and/or defective sensor
Replace the cable and/or sensor
S03 (blocking error)
Open circuit in sensor 2 of
temperature sensor T
1
at
the top of the tank
(1)
.
Sensor is not (correctly) connected
Connect the sensor lead to JP5
Damaged cable and/or defective sensor
Replace the cable and/or sensor
S04 (blocking error)
Open circuit from
dummy 1.
Dummy is not (correctly) connected
Connect the dummy sensor (dummy sensor
1 and 2) leads to JP4.
Defective dummy
Replace the dummy sensor
S05 (blocking error)
Open circuit from
dummy 2
Dummy is not (correctly) connected
Connect the dummy sensor (dummy sensor
1 and 2) leads to JP4.
Defective dummy
Replace the dummy sensor
S11 (blocking error)
Short circuit in
temperature sensor T
2
at
the bottom of the tank.
Short circuit in sensor circuit
Replace the cable and/or sensor.
S12 (blocking error)
Short circuit in sensor 1 of
temperature sensor T
1
at
top of tank
(1)
Short circuit in sensor circuit
Replace the cable and/or sensor.
S13 (blocking error)
Short circuit in sensor 2 of
temperature sensor T
1
at
the top of the tank
(1)
.
Short circuit in sensor circuit
Replace the cable and/or sensor.
S14 (blocking error)
Short circuit from
dummy 1
Short circuit in sensor circuit
Replace the cable dummy sensor
(2)
.
S15 (blocking error)
Short circuit from
dummy 2
Short circuit in sensor circuit
Replace the cable dummy sensor
(2)
.
F01 (blocking error)
Defect in power supply
circuit
Live and neutral connected wrong way
around.
Be sure to connect the live and neutral
correctly (see section 7.7); the water heater
is phase-sensitive
Condensation on the flame probe
Disconnect the lead at the flame probe
Ignite the water heater three times, with
an interrupted ionisation circuit
Reconnect the ionisation lead to the
flame probe
Ignite the water heater again
The repeated ignition attempts will have
caused the condensation to evaporate
•
•
•
•
•
Floating neutral
Install an isolating transformer (see section
7.7.3.1)
92
Installation, Maintenance and Service part
Содержание BFC Cyclone 28
Страница 6: ...6...
Страница 13: ...User part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 13...
Страница 14: ...14...
Страница 16: ...16 User part...
Страница 18: ...18 User part...
Страница 24: ...24 User part...
Страница 41: ...Installation Maintenance and Service part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 41...
Страница 42: ...42 User part...
Страница 46: ...46 Installation Maintenance and Service part...
Страница 52: ...52 Installation Maintenance and Service part...
Страница 59: ...Fig Venting systems 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 59...
Страница 76: ...76 Installation Maintenance and Service part...
Страница 78: ...78 Installation Maintenance and Service part...
Страница 84: ...84 Installation Maintenance and Service part...
Страница 102: ...Fig Dimensions BFC 28 30 50 60 102 Installation Maintenance and Service part...
Страница 104: ...Fig Dimensions BFC 80 100 120 104 Installation Maintenance and Service part...
Страница 112: ...12 7 Declaration of conformity 112 Installation Maintenance and Service part...
Страница 113: ......
Страница 114: ......
Страница 118: ...116 Installation Maintenance and Service part...