week program and the programmed temperature. The fourth line shows the text
PROGRAM ACTIVATED.
The appliance's default week program switches the appliance on every day at 00:00 and
off at 23:59. The default water temperature setting is 65 ºC.
If you want, you can change every setting in the appliance's standard week program.
If the water temperature becomes too low while the week program is running, the
appliance will run through the heating cycle (see section 4.1.1) and return to the week
program.
The following topics are covered here:
Starting and stopping the week program (see section 4.3.5)
Changing the appliance's standard week program (see section 4.3.6)
Adding times to a week program (see section 4.3.7)
Deleting times from a week program (see section 4.3.8)
4.3.5
Starting and stopping the week program
The week program can be started up from any other operating mode, as follows:
[
]: WEEK PROGRAM | START OPERATION
Confirm with [ENTER].
A week program can be shut down simply by activating a different operating mode, for
example the ON mode.
4.3.6
Changing the appliance's standard week program
Note
First fill-in the desired week program on the supplied week program card.
A week program is made up of a number of programmable periods in which you can have
the appliance switch on and off. A period consists of:
switch-on time: day of the week, hours and minutes
switch-off time: hours and minutes
the water temperature setting
on/off setting for a program-controlled pump.
Note
The switch-off time must always be followed by a switch-off time on the same day of the
week. A maximum of three periods may be programmed per day. You can program a
maximum of 21 periods.
Call up the menu for the week program as follows:
[
]: WEEK PROGRAM | PROGRAM OVERVIEW.
Confirm with [ENTER].
The display shows the menu for the week program, see the figure below. With the default
setting, the program switches on and off every day at 00:00 and 23:59 respectively, the
water temperature is 65ºC and the pump is switched on (P).
•
•
•
•
1.
n
•
•
•
•
n
•
0311704_BFC_28-120_III_
ENEN_V2.4, 2022-10-17
31
Содержание BFC Cyclone 28
Страница 6: ...6...
Страница 13: ...User part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 13...
Страница 14: ...14...
Страница 16: ...16 User part...
Страница 18: ...18 User part...
Страница 24: ...24 User part...
Страница 41: ...Installation Maintenance and Service part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 41...
Страница 42: ...42 User part...
Страница 46: ...46 Installation Maintenance and Service part...
Страница 52: ...52 Installation Maintenance and Service part...
Страница 59: ...Fig Venting systems 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 59...
Страница 76: ...76 Installation Maintenance and Service part...
Страница 78: ...78 Installation Maintenance and Service part...
Страница 84: ...84 Installation Maintenance and Service part...
Страница 102: ...Fig Dimensions BFC 28 30 50 60 102 Installation Maintenance and Service part...
Страница 104: ...Fig Dimensions BFC 80 100 120 104 Installation Maintenance and Service part...
Страница 112: ...12 7 Declaration of conformity 112 Installation Maintenance and Service part...
Страница 113: ......
Страница 114: ......
Страница 118: ...116 Installation Maintenance and Service part...