manualshive.com logo in svg
background image

lImIteD warrantY

Equipment manufactured by A.J. Antunes & Co. has been constructed of the finest materials avail-

able and manufactured to high quality standards.  These units are warranted to be free from defects 

in materials and workmanship for a period of one year from date of purchase under normal use and 

service, and when installed in accordance with manufacturer’s recommendations*.  The ultra filtration 

membrane cartridge is warranted under the same terms and conditions on a prorated basis for 24 

months from date of purchase.

*To ensure continued proper operation of the units, follow the maintenance procedure outlined in the 

owner’s Manual.

  1.  This warranty does not cover failures due to improper system installation, defects caused by improper 

storage or handling prior to placing of the equipment into service.  This warranty does not include 

overtime charges or work done by unauthorized service agencies or personnel.  This warranty does 

not cover normal maintenance, calibration, or regular adjustments as specified in operating and main

-

tenance instructions of this manual, and/or labor involved in moving adjacent objects to gain access to 

the Equipment.  

  2.  A.J. Antunes & Co. reserves the right to make changes in design or add any improvements on any 

product.  The right is always reserved to modify equipment because of factors beyond our control and 

government regulations.  Changes to update equipment do not constitute a warranty charge.

 3. 

If shipment is damaged in transit, the purchaser should make a claim directly upon the carrier.  

careful inspection should be made of the shipment as soon as it arrives and visible damage should 

be noted upon the carrier’s documentation.  Damage should be reported to the carrier.  this damage 

is not covered under this warranty.

 4. 

ThIS WARRANTy IS ExcLuSIVE AND IS IN LIEu oF ALL oThER WARRANTIES, ExPRESSED 

oR IMPLIED, INcLuDINg ANy IMPLIED WARRANTy oR MERchANTABILITy oR FITNESS FoR 

A PARTIcuLAR PuRPoSE, EAch oF WhIch IS hEREBy ExPRESSLy DIScLAIMED.  ThE REM

-

EDIES DEScRIBED ABoVE ARE ExcLuSIVE AND IN No EVENT ShALL A.j. ANTuNES & co. 

BE LIABLE FoR SPEcIAL coNSEquENTIAL oR INcIDENTAL DAMAgES FoR ThE BREAch oR 

DELAy IN PERFoRMANcE oF ThIS WARRANTy.

Prices and specifications are subject to change without notice.

Содержание vizion UFC-420

Страница 1: ...Water filtration system UFC 420 440 Series Owner s Manual P N 1010908 Rev A 03 12 Manufacturing Numbers 9700610 9700612 9700614 9700616...

Страница 2: ...arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are...

Страница 3: ...he equipment is furnished with a properly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this manual...

Страница 4: ...person This equipment is to be installed to comply with the local plumbing code and any other applicable code Water pressure must not exceed the membrane differential pressure of 45 psig 3 1 bar To r...

Страница 5: ...his appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Specifications Filter Cartridges Maximum Operating Pressure 3 bar 45 psi Maximum O...

Страница 6: ...FC 420 440 water Filtration system 6 P N 1010908 Rev A 03 12 A J Antunes Co Specifications Figure 2 Components Components LED Display Program Button Power Cord Water Inlet Drain Permeate Product Water...

Страница 7: ...OTE This unit is designed to use tap water not to exceed 104 F 40 C The UFC 420 and UFC 440 systems use the following connections Figure 1 Water Inlet 3 4 NPT Permeate Product Water 3 4 NPT Drain 3 4...

Страница 8: ...tem hold a bucket or other con tainer at the inlet water line and slowly open the inlet water valved Allow the pipe to flush until all debris is removed Permeate Line Plumbing To ensure the highest qu...

Страница 9: ...esting the protective solution may cause irrita tion of the gastrointestinal tract colic diarrhea or other similar symptoms Installation continued 8 After 15 minutes without water flow open the tap fo...

Страница 10: ...rder to keep water filtering during a power outage Figure 4 LED Display Front Panel LED Display Fi Flush Interval Mode is the time between flushings and is displayed in minutes or hours Fd Flush Durat...

Страница 11: ...eturns to Flush Interval Mode NOTE Fi times are displayed in ten minute inter vals after fifty minutes they are displayed in hours Table A Figure 7 LED Display for Flush Duration Mode Figure 8 Time Se...

Страница 12: ...intervals after fifty minutes they are displayed in hours Table B TO SET FD FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is dis...

Страница 13: ...button down for 6 7 seconds until the LED displays FL Figure 11 Continue holding the button down to keep the drain open Drain will remain open for as long as start button is depressed FL will flash o...

Страница 14: ...n the strainer by unscrewing the cap Water will flow out of the strainer as the system drains 4 Press and hold the Start button to help drain the system 5 Reattach the cap on the strainer when the wat...

Страница 15: ...l growth in pipes Sanitize plumbing Water conditions changed Consider installing taste and odor filtration Broken capillary in Filter Cartridge Replace Filter Cartridge Flush runs continuously Drain V...

Страница 16: ...UFC 420 440 water Filtration system 16 P N 1010908 Rev A 03 12 A J Antunes Co Replacement parts UFC 420 440 10 9 11 16 17 16 18 15 26 27 1 28 5 2 12 22 23 4 3 24 25 19 20 UFC 420 440...

Страница 17: ...Mounting Bracket Weldment UFC 420 1 0021332 Mounting Bracket Weldment UFC 440 1 12 0021455 Main Housing Weldment UFC 420 1 0021460 Main Housing Weldment UFC 440 1 15 2090122 Cartridge Filter 4 x 20 1...

Страница 18: ...908 Rev A 03 12 A J Antunes Co Wiring Diagram TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHE...

Страница 19: ...UFC 420 440 water filtration system 19 P N 1010908 Rev A 03 12 A J Antunes Co Notes...

Страница 20: ...operating and main tenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Отзывы: