manualshive.com logo in svg
background image

UFC-420/440 water Filtration system

4

P/N 1010908 Rev. A 03/12

A.J. Antunes & Co.

ImpOrtant safetY InfOrmatIOn (continued)

The following warnings and cautions appear throughout 

this manual and should be carefully observed.

  •  Turn the unit off and disconnect the power source 

before performing any service or  

maintenance on the unit.

  •  The equipment should be grounded according to 

local electrical codes to prevent the possibility of 

electrical shock.  It requires a grounded recep-

tacle with separate electrical lines, protected by 

fuses or circuit breaker of the proper rating.

  •  All electrical connections must be in accordance 

with local electrical codes and any other appli-

cable codes.

  •  WARNINg ELEcTRIcAL ShocK hAzARD.  

FAILURE To FoLLoW THESE INSTRUCTIoNS 

couLD RESuLT IN SERIouS INjuRy oR 

DEATh.

- Electrical ground is required on this  

appliance.

-  Do not modify the power supply cord plug.  If 

it does not fit the outlet, have a proper outlet 

installed by a qualified electrician.

-  Do not use an extension cord with this appli

-

ance.

-  Check with a qualified electrician if you are in 

doubt as to whether the appliance is properly 

grounded.

  •  If the supply cord is damaged, it must be 

replaced by the manufacturer or its service agent 

or a similarly qualified person.

  •  This equipment is to be installed to comply with 

the local plumbing code and any other applicable 

code.

  •  Water pressure must not exceed the membrane 

differential pressure of 45 psig (3.1 bar). To 

reduce water pressure, install a water pressure 

regulator and set the system inlet water pressure 

to 45 psi (3.1) bar.

Inlet water 

pressure 

(psi)

Inlet turbidity 

(ntU)

required additional equipment 

Installed

water Use 

(Gallons per 

Day)

flush program

Less than 45 psi

Less than 1 NTU

Required:

 No additional equipment 

Recommended:

 Inlet water strainer 

(150 micron/ 100 mesh screen) 

Recommended:

 Permeate Tank

Less than 

300 gPD

Greater than 

300 gPD  

Flush Program: 

Interval: 6 hour 

Duration: 15 seconds

Flush Program: 

Interval: 1 hour 

Duration: 15 seconds

Greater than  

45 psi

Less than 1 NTU

Required:

 Pressure regulator 

Recommended:

 Inlet water strainer 

(150 micron/ 100 mesh screen) 

Recommended:

 Permeate Tank

Less than 

300 gPD

Greater than 

300 gPD 

Flush Program: 

Interval: 6 hour 

Duration: 15 seconds

Flush Program: 

Interval: 1 hour 

Duration: 15 seconds

Less than 45 psi

Greater than 

1 NTU

Required: 

Inlet water strainer (150 

micron/ 100 mesh screen) 

Required:

 Permeate Tank

Any

Flush Program: 

Interval: 1 hour 

Duration: 15 seconds

Greater than  

45 psi

Greater than 

1 NTU

Required:

 Pressure regulator 

Required: 

Inlet water strainer (150 

micron/ 100 mesh screen) 

Required:

 Permeate Tank

Any

Flush Program: 

Interval: 1 hour 

Duration: 15 seconds

water cOnDItIOn eqUIpment GUIDelInes

Содержание vizion UFC-420

Страница 1: ...Water filtration system UFC 420 440 Series Owner s Manual P N 1010908 Rev A 03 12 Manufacturing Numbers 9700610 9700612 9700614 9700616...

Страница 2: ...arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are...

Страница 3: ...he equipment is furnished with a properly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this manual...

Страница 4: ...person This equipment is to be installed to comply with the local plumbing code and any other applicable code Water pressure must not exceed the membrane differential pressure of 45 psig 3 1 bar To r...

Страница 5: ...his appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Specifications Filter Cartridges Maximum Operating Pressure 3 bar 45 psi Maximum O...

Страница 6: ...FC 420 440 water Filtration system 6 P N 1010908 Rev A 03 12 A J Antunes Co Specifications Figure 2 Components Components LED Display Program Button Power Cord Water Inlet Drain Permeate Product Water...

Страница 7: ...OTE This unit is designed to use tap water not to exceed 104 F 40 C The UFC 420 and UFC 440 systems use the following connections Figure 1 Water Inlet 3 4 NPT Permeate Product Water 3 4 NPT Drain 3 4...

Страница 8: ...tem hold a bucket or other con tainer at the inlet water line and slowly open the inlet water valved Allow the pipe to flush until all debris is removed Permeate Line Plumbing To ensure the highest qu...

Страница 9: ...esting the protective solution may cause irrita tion of the gastrointestinal tract colic diarrhea or other similar symptoms Installation continued 8 After 15 minutes without water flow open the tap fo...

Страница 10: ...rder to keep water filtering during a power outage Figure 4 LED Display Front Panel LED Display Fi Flush Interval Mode is the time between flushings and is displayed in minutes or hours Fd Flush Durat...

Страница 11: ...eturns to Flush Interval Mode NOTE Fi times are displayed in ten minute inter vals after fifty minutes they are displayed in hours Table A Figure 7 LED Display for Flush Duration Mode Figure 8 Time Se...

Страница 12: ...intervals after fifty minutes they are displayed in hours Table B TO SET FD FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is dis...

Страница 13: ...button down for 6 7 seconds until the LED displays FL Figure 11 Continue holding the button down to keep the drain open Drain will remain open for as long as start button is depressed FL will flash o...

Страница 14: ...n the strainer by unscrewing the cap Water will flow out of the strainer as the system drains 4 Press and hold the Start button to help drain the system 5 Reattach the cap on the strainer when the wat...

Страница 15: ...l growth in pipes Sanitize plumbing Water conditions changed Consider installing taste and odor filtration Broken capillary in Filter Cartridge Replace Filter Cartridge Flush runs continuously Drain V...

Страница 16: ...UFC 420 440 water Filtration system 16 P N 1010908 Rev A 03 12 A J Antunes Co Replacement parts UFC 420 440 10 9 11 16 17 16 18 15 26 27 1 28 5 2 12 22 23 4 3 24 25 19 20 UFC 420 440...

Страница 17: ...Mounting Bracket Weldment UFC 420 1 0021332 Mounting Bracket Weldment UFC 440 1 12 0021455 Main Housing Weldment UFC 420 1 0021460 Main Housing Weldment UFC 440 1 15 2090122 Cartridge Filter 4 x 20 1...

Страница 18: ...908 Rev A 03 12 A J Antunes Co Wiring Diagram TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHE...

Страница 19: ...UFC 420 440 water filtration system 19 P N 1010908 Rev A 03 12 A J Antunes Co Notes...

Страница 20: ...operating and main tenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Отзывы: