RAPID TOASTER VCT-200
16
P/N 1010710 Rev. N 02/13
McDonald’s
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel. The unit should be unplugged when servicing,
except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will
be exposed.
Problem
Possible Cause
Corrective Action
No Display.
No light on Power Switch
Unit Not Plugged in.
Plug power cord into proper power outlet.
Hi-Limit tripped.
Reset Hi-Limit switch.
Circuit Breaker tripped.
Reset Circuit Breaker.
Power Cord and/or plug are
damaged.
Contact your maintenance person or an
Authorized Service Agency for service.
Inoperable on/off switch.
Temperature display flashes
“PO.”
Voltage to the unit is below
190 volts.
Turn the Rocker Switch (power On/Off) to OFF,
then On. If the display shows “PO” again,
check the power cord and plug receptacle for
damage.
Reset Circuit Breaker located at the store’s
power panel.
Contact your maintenance person or Authorized
Service Agency for service.
Temperature display reads
“LO.”
Platen temperature is below
420° F(216° C).
Allow thirty minutes for warmup and recheck
the display.
Contact your maintenance person or Authorized
Service Agency for service.
Temperature display flashes
“HI” at cold start.
Platen Thermocouple is dis-
connected or open.
Reattach or replace Platen Thermocouple.
Inoperable Control Board.
Contact your maintenance person or Authorized
Service Agency for service.
Temperature display flashes
“HI” and “LO” at cold startup.
Auxiliary Thermocouple is dis-
connected or open.
After preheat time, display
flashes “HI” and “USE.”
Temperature display flashes
“HI” and “USE” after unit has
been preheated, and belt wraps
may start to smoke.
Auxiliary circuit overheating
due to auxiliary solid state
relay shorted closed.
Display reads “CHEC”.
Ambient temperature in control
compartment too high.
“CHEC” is showing in temperature display. Turn
toaster off and allow control compartment to
cool down to 140°F (60°C) and restart toaster.
Be sure cooling fan is operating and nothing
is blocking the flow of cooling air to bottom of
toaster.
Содержание VCT-200 Series
Страница 25: ...RAPID TOASTER VCT 200 25 P N 1010710 Rev N 02 13 McDonald s WIRING DIAGRAMS Pictorial Wiring Diagram...
Страница 26: ...RAPID TOASTER VCT 200 26 P N 1010710 Rev N 02 13 McDonald s HI LIMIT CONTROL Ladder Wiring Diagram...
Страница 27: ...RAPID TOASTER VCT 200 27 P N 1010710 Rev N 02 13 McDonald s NOTES...
Страница 28: ...RAPID TOASTER VCT 200 28 P N 1010710 Rev N 02 13 McDonald s NOTES...