Xserve (Late 2006) Take Apart — Optical Drive
38
Replacement Note:
Before installing the replacement drive, you must transfer the side
brackets and the screws from the original drive to the replacement drive.
Remove the mounting screw for the left bracket and transfer the bracket to the new drive,
5.
using the same screw to secure it.
Remove the three mounting screws for the right bracket and transfer the bracket to the new
6.
drive, again using the same screws to secure it.