3
dial-up network when Ethernet is not available. If Video Server operates with Ethernet interface,
administrators may use this port to control PTZ camera attached to VIDEO.
General I/O terminal block
1
Å
DI+
INPUT
(Max. 50mA, 12VDC)
2
Å
DI-
INPUT
3
Å
SW_COMMON OUTPUT
(short with NC at initial state)
4
Å
SW_NOPEN
OUTPUT
(Max. 1A, 24VDC or 0.5A, 125VAC)
5
Å
RS485 B
(inverting)
6
Å
RS485 A
(non-inverting)
Video Server provides a very flexible general I/O interface to combine with the user’s security
devices such as sensors, alarms, lighting or door locks. The general I/O terminal block has six
pins for device control. These pins can be divided into two categories based on their functions,
including RS485 and digital inputs and outputs.
If the device connected to COM has an RS485 interface, wire two control lines to pin 5 and pin 6.
After switching to RS485 on the configuration page, the PTZ control commands will be directed
through pin 5 and pin 6. If the distance from the controlled device is too far to allow accurate
function, an external power source may be used to pull high the RS485 signal.
Video Server provides one digital input and one relay switch. Pin 1 and pin 2 can be connected to
external sensor and the state of voltage will be monitored according to the programmed scripts in
configuration. The relay switch can be used to turn on or off external devices.
Содержание IPVS1A
Страница 1: ......
Страница 15: ...10 ...
Страница 18: ...13 conflicts In this case administrators should ask the network supervisor for a vacant IP address ...
Страница 55: ...50 ...
Страница 56: ...51 The following figure shows the screen when is clicked The monitoring windows will be marked by red squares ...
Страница 76: ...71 00 00 00 24 hours format seconds delay before next event 3 ...
Страница 84: ...79 address of 192 168 0 201 to set digital output to connect to NC with COMMON ...