4O3A Signature – Antenna Genius User Manual
Page
19
of
56
Use a Cat5e, Cat6 or Cat6a UTP cable (not supplied, please don’t use a cheap cable here; poor-
quality high-speed data cables are never a good idea!) between the Ethernet port on your AG
and your station LAN switch or hub (switches preferred over hubs). This should be the same
place where your FLEX-6000 Signature Series radio connects to your LAN. Note this LAN
connection can be as simple as a port on a DSL router or as fancy as a standalone Gigabit switch.
AG can be controlled by PCs connected over WiFi to your LAN as long as AG itself is connected
directly to your LAN via a wired connection to an Ethernet switch or hub (switch recommended;
Ethernet hubs will slow down your LAN).
8.7.
DIP Switch configurations
As of version 4.1.0. DIP switches are no longer used to configure band data sources, ID or group
ID.
Important:
All these settings are now done through the Windows app utility program and the
position of DIP switches 1 through 6 doesn’t do anything.
DIP 7
is used to
reset your
AG config settings to default
and
sets the IP setting to DHCP
(see
Section 9.2 below).
DIP 7
ON
restore factory settings on next power cycle
OFF
normal operation
To reset AG configuration and IP settings follow these steps in order:
1.
remove DC power from AG
2.
move DIP 7 to ON position
3.
turn DC power back on
4.
move DIP 7 back to OFF position
DIP 8
is used to
force your AG into bootloader mode
to enable you to re-upload the firmware
to the device.
This is used when your AG gets bricked (unresponsive) for whatever reason – due to
configuration, power failure in some critical state tetc.