ENGLISH
28
7.39 Reading the cycle counter
The control is equipped with an integrated counter, which stores
completed opening cycles. A maintenance counter is also
integrated, which indicates that maintenance is required once the
set value is reached.
The counters diff er as follows:
• The cycle counter
tot
cannot be reset.
• The maintenance counter
MAn
indicates the cycles remaining
until maintenance is due and can be switched off early or reset
to the desired maintenance interval.
The diagram shown indicates reading off the existing cycles,
the cycles remaining until maintenance is due and setting the
new maintenance interval. In the example, the control has
executed 12451 cycles and there are 1322 cycles remaining until
maintenance is due.
Area 1
indicates the counter status of executed cycles. Pressing
the
or
button displays the thousand or hundred scale.
Area 2
indicates the remaining cycles until maintenance is due.
The actual value is rounded to the nearest hundred.
Area 3
is for entry of the number of cycles you wish to be
executed before maintenance is due. Pressing the
or
button
rounds the indicated value to the nearest thousand or hundred,
each additional press increases or decreases the value by 1000
units. This clears the maintenance interval.
7.40 Indicating maintenance due
If the set number of cycles is exceeded, the warning light
indicates that maintenance of the gate system is required. In this
case, the warning light is switched on a for
5 sec.
before each
opening cycle.
Note
Maintenance and repair work may only be carried out be expert
personnel.
Indication of maintenance due (signalisation by the warning
light) is terminated only when a new maintenance interval is
entered or the previous interval is cleared. If the counter is set
to "
0
", the maintenance counter is deactivated.
2
1
3
OK
OK
OK
OK
Ï
Ð
OK
OK
OK
Ï
OK
Ï
Ð
Ï
Ï
Ð
Ð
Содержание CX1024
Страница 1: ...www 4ddoors com au instructions for fitting operating and maintenance Sliding operator CX1024 ...
Страница 2: ...2 A B Ø 12 mm Ø 5 5 mm 17 mm 3 mm 2 17 5 mm 3 mm PIC 01 ...
Страница 12: ...ENGLISH 12 DX SX DX SX 11 Figure 11 End positions Max 38 mm 102 mm 12 Figure 12 Distances ...
Страница 37: ...ENGLISH 37 ...
Страница 42: ...2906380 www 4ddoors com au instructions for fitting operating and maintenance Sliding operator CX1024 ...