19

2. OBSTRUCTION FORCE ADJUSTMENT

CAUTION: The obstruction force adjustment is set 
automatically during programming. Normally no 
adjustment is necessary.

a.  Press and hold the 

SET

 Button until “1”appears on the 

display, next press the UP Button until “2” appears on 
the display to enter this function setting then release 
the button.

b. Press the 

SET

 button again, The unit is now in force 

adjustment mode. And then you will see a figure “3” 
with flash dot appears on the display.

c.  Press the 

UP

 button to increase the force setting or the 

DOWN

 button to decrease the force setting.

d. The minimum force is “1” and it can be adjusted upward. 

The maximum force is “5”.

Press the 

SET

 button to confirm the set and it will back to 

standby status automatically and display “ll”.

NOTE

: The force is set on “3” as standard in factory.

PROGRAMMING INSTRUCTIONS

INCREASE FORCE

DECREASE FORCE

Содержание 4DS2 v1

Страница 1: ...Installation instructions and user guide Sectional and Tilting door operator 4DS2 v1...

Страница 2: ......

Страница 3: ...ed person Attempting to install or repair the door opener without suitable technical qualification may result in severe personal injury death and or property damage WARNING Installation Instructions a...

Страница 4: ......

Страница 5: ...n Steel Track Installation Sectional Steel Track Assembly Battery Backup Assembly optional Display Menu Instructions Plus II Programming Instructions Terminal Introduction and Application Manual Disen...

Страница 6: ...dards and installation manual whether directly or indirectly This opener incorporates a pressure sensitive Safety Obstruction Force system It must be configured correctly by a qualified installer Its...

Страница 7: ...e Safety Obstruction System is designed to work on STATIONARY objects only Serious personal injury death and or property damage may occur if the garage door comes into contact with a moving object 15...

Страница 8: ...mountings for signs of wear damage or imbalance Do not use if repair or adjustment is needed since a fault in the installation or an incorrectly balanced door may cause injury Each month check that t...

Страница 9: ...gnition function is enabled Each transmitter button is now grouped to a common code 6 Codes memory quantity If A appears on the display it means the maximal code memory quantity is 50 Press the UP DOW...

Страница 10: ...is available The Openers can be powered by an optional battery backup This allows continued operation in the event of a power failure at your home 16 Manual release A manual release system allows for...

Страница 11: ...e unit is being installed on an existing door make sure any existing locking devices are removed or warranty will be void 4 An approved outlet must be installed near where the opener is being installe...

Страница 12: ...t 2cm 15cm above the door on the inside wall Depend on the actual installation space Door Bracket Fix the door bracket to a structural part of the door as close to the top edge as possible INSTALLATIO...

Страница 13: ...d secure it with the split pin supplied STEP3 Fig 3 Fig 4 Lift and support the opener head with a ladder so it is positioned centrally and level Fix the opener and track on ceiling steel bracket A B S...

Страница 14: ...ve slide the E rail into the sleeve 2 Cut the plastic thread and pull the screw rod along with inner chain to the end rail position shown in Fig 8 3 As Fig 9 release the nut spring 4 Tighten the nut t...

Страница 15: ...t per fig 1 then STEP2 Fig 12 Assemble the battery to opener Fig 12 fix by screws suppled Option 2 Side Fixed STEP1 Fig 13 Assemble the battery battery bracket per Fig 13 STEP2 Fig 14 Assemble the bat...

Страница 16: ...1 E where E is the feature number c Press the SET button to enter the interface for detailed settings of the selected feature d In the detail setting interface it displays 0 A with a flashing dot e P...

Страница 17: ...button The door will open 4 Short press the DOWN button The door will close When the door is opening or closing it will stop if you press any key 5 Long press the SET button Enter the function settin...

Страница 18: ...the DOWN button until the door reaches the desired close position you will see u without dot on the display NOTE For fine adjustments toggle UP DOWN buttons f Now press the SET button to confirm the c...

Страница 19: ...Press the SET button again The unit is now in force adjustment mode And then you will see a figure 3 with flash dot appears on the display c Press the UP button to increase the force setting or the DO...

Страница 20: ...nction setting then release the button b Press the SET button again The unit is now in speed adjustment mode And then you will see a letter A with flash dot appears on the display c Press the UP DOWN...

Страница 21: ...appears on the display c Press UP Down button once to set the auto close time 0 9 d Press the UP button to increase the time or the DOWN button to decrease the time The close time is 15second N N 0 9...

Страница 22: ...s UP Down button once to set the auto close condition You can choose 1 or 2 set Figure 1 means the door only can auto close while in the open limit position Figure 2 means the door can auto close whil...

Страница 23: ...en you will see a figure 3 with flash dot appears on the display c Press UP Down button once to set the LED off delay time 1 9 d Press UP button to increase the time or DOWN button to decrease the tim...

Страница 24: ...play c Press UP Down button once to set the reversal height while closing 0 9 d Press the UP button to increase or the DOWN button to decrease Figure 0 means the door will rebound to the open limit po...

Страница 25: ...n to decrease Figure 0 means close the partial open function Figure 1 9 means set the partial open position of the whole travel One tenth to Nine tenth of the whole travel etc d Press the SET button t...

Страница 26: ...th 1 opener then its top or bottom pair will also control the opener It s convenient for the users who only have 1 automation door at home Figure 1 means the buttons recognition function is open If yo...

Страница 27: ...A again but with flash dot appears on the display c Press UP Down button once to set the remote quantity A or 1 9 d Figure A means the maximal quantity 50pcs Press UP DOWN button once to increase or d...

Страница 28: ...button once to set the reversal height ignorance while closing 0 9 d Press the UP button to increase or the DOWN button to decrease Figure 1 9 means the door will still not rebound even though there s...

Страница 29: ...switch type adjustment mode And then you will see a figure 0 with flash dot appears on the display c Press UP Down button once to set the wicket door switch type You can choose 0 or 1 set Figure 0 mea...

Страница 30: ...button until d appears on the display to enter this function setting then release the button b Press the SET button again The unit is now in the photo cell ON OFF adjustment mode And then you will se...

Страница 31: ...time In order to make you notice that your garage door need to do maintenance And at the same time you will see a figure t appears on the display Figure 2 means the maintenance alarm count cycle is s...

Страница 32: ...ener The switch must have voltage free normally open contacts PROGRAMMING INSTRUCTIONS Photo beam connection optional Fig 15 Fig 16 Switch control connection optional Fig 15 Remark 1 Flash Caution Lig...

Страница 33: ...g interfaces for this function and provide 24v 35v flash light voltage Connect the flash light with DC 24v 28v current 100mA When use AC 220V power flash lights please match an adapter and wiring as r...

Страница 34: ...age the door simply run opener in automatic mode or move door by hand until the trolley engages in the chain shuttle If the garage does not have a pedestrian access door an emergency access device mus...

Страница 35: ...ip service part item 3 Take the lamp cover away and then unplug the old LED light Replace with a new LED light strip and refit the lamp cover 3 Before installing a caution light please ensure the rate...

Страница 36: ...ransformer Overload protection technology Radio frequency 433 92 MHz Coding format Rolling code 7 38 x 1019 Combinations Status display transmitter 2 X Code storage capacity 50 different codes Caution...

Страница 37: ...on 13 1 Transformer 14 1 Chain Belt rail 15 1 Chain Belt connection 16 1 Trolley assy 17 1 Straight arm 18 1 Bent arm 19 2 Transmitter 20 1 Transmitter bracket 21 1 Door bracket 22 1 Wall bracket 23 1...

Страница 38: ...ds are acceptable Correct or continue to reset force limits LED light will flash quickly for 10 times Digital display The gear motor cannot self lock well Replace the gear motor Opener is not working...

Страница 39: ...Door automatically stops while opening In operation with automatic protect function when obstruction is detected The door is not installed correctly There is some track binding 1 Check for track bind...

Страница 40: ...nt is not intended to create a contract between 4D Garage Doors and the purchaser Except for this warranty 4D Garage Doors gives no warranties of any kind whatsoever whether express or implied in rela...

Страница 41: ...n authorised 4D Garage Doors dealer and this dealer cannot be contacted then notification must be made as soon as practicable to 4D Garage Doors f This Warranty is limited to Return to Base RTB repair...

Страница 42: ...dditional access or equipment required Expenses incurred by 4D Garage Doors or its authorised dealer required to provide clear access or the equipment used to access the Product for example Lifting ha...

Страница 43: ...ed warranty claim form to 4D Garage Doors directly If the Product was supplied by an authorised 4D Garage Doors dealer please provide the copy of your original receipt along with a completed warranty...

Страница 44: ...www 4ddoors com au instructions for fitting operating and maintenance Sectional and Tilting door operator 4DS2 v1...