Storage Settings
Before you start:
To configure recording settings, please make sure that you have the network storage device or local storage
device configured.
13.1
Configuring Record Schedule
Purpose:
There are two kinds of recording for the camera: manual recording and scheduled recording. In this section,
you can follow the instructions to configure scheduled recording. By default, files recorded via scheduled
recording are stored in the local storage (on-board SD Card).
Steps:
1.
Enter the Record Schedule Settings interface:
Configuration > Storage > Schedule Settings > Record Schedule.
Figure 13-1
Recording Schedule Interface
2.
Check off Enable to enable scheduled recording.
3.
Click Advanced to set the camera recording parameters.
Figure 13-2
Record Parameters
Pre-record:
The time you set to start recording before the scheduled time or event. For example, if an
alarm triggers recording at 10:00, and the pre-record time is set as 5 seconds, the camera starts to
record at 9:59:55. The Pre-record time can be configured as No Pre-record, 5s, 10s, 15s, 20s, 25s, 30s
or not limited.