Chapter 2. Primary CLI Syntax Reference
74
3ware 9000 Series Serial ATA Controller CLI Guide
/cx/bbu show lasttest
This command shows the date the battery capacity was last measured. If the
battery capacity test has never been run, then 'xx-xxx-xxxx' will be displayed.
Note:
The estimated BBU capacity hours displayed is based on the
measurement taken during the last test. If you have not run the BBU test
command for some time, this number can be misleading. For information
about running a test, see “/cx/bbu test [quiet]” on page 75.
/cx/bbu show volt
This command shows the voltage status of the battery. The status can be OK,
HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are in
warning range. TOO-HIGH and TOO-LOW are out of the operating range
and indicate that it is time to replace the battery. (Contact AMCC to obtain a
replacement battery.)
/cx/bbu show temp
This command shows the temperature status of the battery. The status can be
OK, HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are in
warning range. TOO-HIGH and TOO-LOW are out of the operating range
and indicate that it may be time to replace the battery. (Contact AMCC to
obtain a replacement battery.)
/cx/bbu show cap
This command shows the battery capacity in hours.
A value of '0 hours' will be displayed if the battery capacity test has never
been run.
Note:
The estimated BBU capacity hours displayed is based on the
measurement taken during the last test. If you have not run the BBU test
command for some time, this number can be misleading. You can use the
command
/cx/bbu show lasttest
to check the date of the last test. For
information about running a test, see “/cx/bbu test [quiet]” on page 75.
/cx/bbu show serial
This command shows the BBU serial number.
/cx/bbu show fw
This command shows the BBU firmware version number.