Chapter 2. Primary CLI Syntax Reference
66
3ware 9000 Series Serial ATA Controller CLI Guide
Example of migrate output
The following is an example of how migrating units will be displayed. In this
example, the report indicates that
/c0/u0
is a migrating unit with 67%
completion. The report also indicate that Source Unit
su0
is of type RAID-1
and Destination Unit
du0
is of type RAID-10.
//localhost> /c0/u0 migrate type=raid10 disk=2-3 stripe=16
Sending migration message to /c0/u0 ... Done.
3ware CLI> /c0 show
Unit UnitType Status %Cmpl Stripe Size(GB) Cache AVerify IgnECC
------------------------------------------------------------------------------
u0 Migrator MIGRATING 0 - 74.4951 ON OFF OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 74.53 GB 156301488 3JV2Q1VA
p1 OK u0 232.83 GB 488281250 WD-WMAEH15764
p2 OK u0 232.83 GB 488281250 WD-WMAEH17004
p3 OK u0 232.83 GB 488281250 WD-WMAEH17000
p4 NOT-PRESENT - - - -
p5 NOT-PRESENT - - - -
p6 NOT-PRESENT - - - -
p7 NOT-PRESENT - - - -
p8 NOT-PRESENT - - - -
p9 NOT-PRESENT - - - -
p10 NOT-PRESENT - - - -
p11 NOT-PRESENT - - - -
3ware CLI> /c0/u0 show
Unit UnitType Status %Cmpl Port Stripe Size(GB) Blocks
-----------------------------------------------------------------------
u0 Migrator MIGRATING 0 - - - -
su0 RAID-1 OK - - - 74.4951 156227584
su0-0 DISK OK - p0 - 74.4951 156227584
su0-1 DISK OK - p1 - 74.4951 156227584
du0 RAID-10 OK - - 16K 148.99 312455168
du0-0 RAID-1 OK - - - - -
du0-0-0 DISK OK - p0 - 74.4951 156227584
du0-0-1 DISK OK - p1 - 74.4951 156227584
du0-1 RAID-1 OK - - - - -
du0-1-0 DISK OK - p2 - 74.4951 156227584
du0-1-1 DISK OK - p3 - 74.4951 156227584