TCP server
TCP Server, Passive connect, one pivotal parameter is [Local port], have
relationship with other setting, need combine setting
[Local port]
Switch provided TCP port can be connect by other TCP/IP node, the TCP port
have the relationship with the Switch
’s relevant serial interface. The figure as
follows is TCP Server setting interface, Session 1 set local port is 30000, external
TCP port connect Switch through this port. Connection keep-alive time is 300
second
。
Cl
ick “Apply”, setting successful.
UDP
Under the UDP work mode. SWITCH is server and also client, the relevant
setting is “Local port”, “Target address” and “Target port”. It can support point to
point and multicast UDP, setting method is the same as TCP.
TCP Auto
In this Mode, serial device server can act as server or client. Before setting this
Mode, please ensure related parameters are correct when you turn on the server
mode, client mode is automatically disconnected.
RealCom
RealCom support TCP Server and TcpAuto, can choice open and close function
in RealCom.
When device open the RealCOM function, can cooperate with VSP Management
Software create virtual COM port to communication, now, device’s work mode is
server, the virtual COM port is client, how to create the Virtual COM port, please
the VSP Management Software user manual.
Advanced mode
TCP server
Under this mode, series is server, SWITCH can choice 0-4 channel connection at
the same time, configuration mode is the same based mode.