Industrial Ethernet Switch User Manual
3onedata proprietary and confidential
7
Copyright © 3onedata Co., Ltd.
data to Ethernet data
Enter into switch WEB interface, knock [Serial Server/COM settings], Please choice
necessary configuration in drop down list, the serial configuration interface is as
follows:
Configuration option: [Baud rate], [Parity], [Data Bits], [Stop Bits], [Max Frame Space],
[Character Delay] and [ COM mode], the explaining is as follows:
[Baud rate]
It is a parameter to check the communication speed. It shows to transfer how many
bits in 1 second.
For example, 300 baud rate means have 300 bits transferred in 1 second.
[Parity]
Parity bits: It is a simple method to checkout fault in serial communication,
have 4 types: Even, Odd, Mark, Space
[Data Bits]
It is a parameter to check the actual data bits in communication.
When PC send a Packet, actual data is not 8 bits, the standard is 5, 6, 7, 8.
[Stop Bits]
The last bit of the single Packet. Typical value is 1, 1.5 and 2 bit.
When data bits is 5, stop bit 1.5 and 1 option. When data bits is 6, 7, 8, stop bit 1 and
2 option.
[Max frame space]