44
Setting up auto-run
Level-triggered auto-on setting
Models SE and DL
Level-triggered auto-on setting
The level-triggered screen contains meter 1 parameters which include a
Filter mode, Frequency level, “Level On” and “Level Off” modes, and a
specification for either run/stop or run/pause modes.
Viewing or changing level-triggered mode
1. From the start screen, press
Up/Down
to highlight
Setup
and
press
Enter
.
2. Select
Auto-Run
by using
Up/Down
to highlight and press
Enter
to select.
3. In the Auto-Run screen, repeatedly press
Enter
until
Level-
Triggered
appears.
4. Press the
Down
arrow to select
View/Set Parameters
and press
Enter
. The Level-Triggered Auto-Run screen will appear.
•
See Table 4-1 below for explanation of settings.
Figure 4-7: Level-Triggered screen
Level-
Triggered
Explanation of Settings
A. Mode
The mode, or Filtered Mode, can be set to Level On/Off and Windowed
settings.
•
In
Level On/Off
mode, the unit starts a run when the source level
exceeds the specified criteria and stops/pauses when level falls below the
off criteria. The on criteria is met and either pause or stop a run when the
off criteria is met.
•
In
Windowed
mode, the unit starts a run when the selected criteria falls
outside the defined window. This is intended primarily for curves but can
also be used with broadband or individual filter measurements.
\setup\LVL-TRG-RUN
MODE
LEVEL ON/OFF
ACTION
RUN/PSE
TRIGGER
RUN PAUSE
SOURCE
METER 1 METER 2
LEVEL
90.0 OFF
Mode
: to enable a
filter mode, select
Level On/Off or
Windowed
Action
: Run/Pause
or Run/Stop
Source/Level:
Select one of the 5
features and then
set an appropriate
Level.
A
B
C
D
Содержание SP-DL-1
Страница 1: ...3M Personal Safety Division 3MTM SoundPro SE DL SeriesSound Level Meters SoundProUser Manual ...
Страница 13: ...xii Table of Contents Models SE and DL This page left blank intentionally ...
Страница 23: ...10 Detection Management Software DMS DMS Start Page Models SE and DL This page left intentionally blank ...
Страница 35: ...22 Turning off Navigating Models SE and DL This page left blank intentionally ...
Страница 69: ...56 Communications GPS Models SE and DL This page left blank intentionally ...
Страница 89: ...76 Back erasing Stopping a session Models SE and DL This page left blank intentionally ...
Страница 123: ...110 Speech Intelligibility STI PA results screens Models SE and DL This page left blank intentionally ...
Страница 137: ...AC DC output DC output 124 Models SE and DL This page left blank intentionally ...
Страница 149: ...Appendix A 136 Models SE and DL Block Diagram for SoundPro ...
Страница 161: ...Appendix B 148 Models SE and DL This page left blank intentionally ...