Filtered Bar Chart screen
For the filtered bar chart screen, the dominant characteristic of this screen is the multi-element bar chart. The chart displays measurements in each filter
band and broadband values for both meters. For octave band analysis, the screen contains 13 bars (11 for filters and 2 for broadband), and for third-octave
analysis the screen contains 35 bars (33 for filters and 2 for broadband) of measurement values. The bars appear (and usually fluctuate) if the measured
value for the bar is above the minimum value for the selected measurement range.
Bar Chart screen
For the
bar chart screen
, the amplitude of the displayed measurement is shown both graphically by the length of the bar and numerically below the bar.
The bar appears (and usually fluctuates) if the measured value is above the minimum value for the selected measurement range.
Community Noise screen
This screen shows the results of measurements commonly associated with community noise studies.
Dosimetry screen
The Dosimetry screen provides several types of measurements of the accumulated personal exposure to noise.
Broadband amplitude
Amplitude in the band
Selected band
Broadband Bar Chart view
Shows SPL average amplitude
(or value) of Meter 1
Will display only if octave
band is enabled
Bar Chart View
Shows SPL average value of Meter 1.
Will display only if SLM is selected as
the measurement mode.
Community Noise View
Only appears on Meter 1 when
you are not viewing the current
study and when the community
noise parameters are activated.
Exceedance levels
L1 = 99% dB
L10 = 85.1% dB
L50 = 82.9% dB
Taxtmaximal
Value is 90 dB at 3 sec.
intervals
Dosimetry View
Shows accumulated personal
exposure to noise.
These measurements are affected
by the settings in the “Meter Set”