background image

 

 

 

 

 

 
 
 
 
 
 

 
 

 

 
 
 

 

 

 

 

1.

 

To turn on the SoundPro, press the 

        

key until the start screen appears. 

 

2.  To navigate, press the up/down        arrows and left/right arrows          for most of the navigational functions. 

   

 

The        key is used to move back one level (or escape from a menu/screen).  Press repeatedly to return to the start screen.  

\

 

 

 The        key is used to open the selected menu/screen.   
 

 

1.

 

Format the card or delete the session files from the SoundPro (optional).  

 

 

To format, select the File softkey from the start screen.  Press the down arrow continuously to select Format.  Press        key.  

 

1.

 

Adjust the settings to fit the specifications of your sound study.  

 

 

To open the Setup menu from the start screen, press the       arrow keys and press        key when selected.  The setup 
menu will appear.  To change the parameters, navigate to the appropriate menus and make changes as needed.  (See the 

user manual for specific details and term explanations for more information.)   

 

 

1.  Display 

 

8.  Softkeys 

12. On/Off and Esc (Escape) key 

2.  Backlight key 

9.  Alt

F key

 

6.  Run/Pause key 

 

Indicators 

 

  Battery power: 

  Stop: 

  Run time: 

00:00:00 

<SLM>    CAL       FILE    COMM 

5.  Up/Down arrow keys 

7.  “Softkey” Menu: 

     Correspond with softkeys     
  

3.  Stop key 

11. Right arrow key 

4.  Left arrow key 

10. Enter key 

Softkey menu 

Measurement type 

  Repeatedly press 1

st

 softkey 

to toggle through to select 1/1, 
1/3, SLM (if purchased) 

Содержание SoundPro SE Series

Страница 1: ...3M Personal Safety Division 3MTM SoundPro SE DL SeriesSound Level Meters SoundProQuick Start Guide ...

Страница 2: ... settings to fit the specifications of your sound study To open the Setup menu from the start screen press the arrow keys and press key when selected The setup menu will appear To change the parameters navigate to the appropriate menus and make changes as needed See the user manual for specific details and term explanations for more information 1 Display 8 Softkeys 12 On Off and Esc Escape key 2 B...

Страница 3: ...re the Post Calibration information A sample screen is displayed below with post calibration history Position the SoundPro in the field Press the run key to start measuring To pause a study for example lunch breaks press the run pause key To start measuring again press the run pause key Continue this process until your measurements are complete by press the Stop key This will end the session 1 Fro...

Страница 4: ... measured value is above the minimum value for the selected measurement range Community Noise screen This screen shows the results of measurements commonly associated with community noise studies Dosimetry screen The Dosimetry screen provides several types of measurements of the accumulated personal exposure to noise Broadband amplitude Amplitude in the band Selected band Broadband Bar Chart view ...

Страница 5: ...trument communication A Click on icon see A to access the Instrument download panel 4 Selecting and viewing data A The Data Finder page see A is used to view select and preview reports Note Click Browse to view all data files B Select the data by clicking on either the session study Note you may need to expand to see the study data C To view in Graphs and Tables click on or buttons B A Data Finder...

Страница 6: ...ality and select toxic combustible gases The 3M Detection brand of instrumentation is used by safety and industrial hygiene professionals to help comply with applicable occupational standards and regulations About 3M Personal Safety 3M offers a comprehensive diverse portfolio of Personal Safety solutions providing respiratory protection hearing protection fall protection reflective materials for h...

Отзывы: