78-8127-8864-0-C 11
5.10 Wrap two half-lapped layers of vinyl tape over all constant force springs
(Figure 21)
.
Vinyl Tape
1/2" Max
(13mm)
Figure 21
Go to Section 7.0 "Install Jacket."
6.0 External Grounding with Ground Wire (Optional)
6.1 Connect a ground wire to the pre-installed ground braid on the integrated splice using an appropriate connector.
Keep connector profile as low as possible. For C-tap or H-tap connectors, position flat against the cable. Crimp
connector following the connector manufacturer’s recommendations
(Figure 22)
.
Ground Wire
Connector
Ground Braid
Figure 22
6.2 Cut one mastic sealing strip into two equal pieces. Place one piece on the cable jacket centered under the
ground wire near the jacket end. Roll two mastic strips into small rolls. Place one roll on either side of the
ground wire.
(Figure 23)
.
Ground Wire
Ground Wire
Rolled Mastic
Half Mastic Strip
Cable Jacket
Rolled Mastic
Half Mastic Strip
Figure 23