SAFETY INFORMATION
Read, understand, and follow all safety information contained in these instructions prior
to installation and use of the Filtrete
™
Standard , Advanced and Maximum Under Sink
Water Filtration Systems. Retain these instructions for future reference.
Intended use:
The Filtrete
™
Standard, Advanced and Maximum Under Sink Water Filtration Systems (3US-AS01, 3US-PS01,
and 3US-MAX-S01) are intended for use in fi ltering potable water and have not been evaluated for other uses.
The product is installed at the point of use and must be installed as specifi ed in the installation instruction by a
qualifi ed professional.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
Indicates a potentially hazardous situation, which, if not avoided, could result in
death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in
property damage.
Read entire Use & Care Guide. Failure to follow all guides and rules could cause personal
injury or property damage.
• Check with your local public works department for plumbing codes. You must follow their guidelines as
you install the water fi ltration system.
• Your water fi ltration system will withstand up to 125 pounds per square inch (psi) water pressure. If your
house water supply pressure is higher than 80 psi, install a pressure reducing valve before installing the
water fi ltration system.
To reduce the risk associated with choking:
• DO NOT allow children under 3 years of age to have access to small parts during the installation of
this product.
To reduce the risk associated with the ingestion of contaminant:
• DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
To reduce the risk associated with hazardous voltage due to an installer drilling through
existing electric wiring or water pipes in the area of installation:
• DO NOT install near electric wiring or piping which may be in path of a drilling tool when selecting the
postilion to mount the fi lter bracket.
NOTICE
To reduce the risk associated with property damage due to water leakage or fl ooding:
NOTICE
WARNING
WARNING
• Read and follow Use & Care Guide before
installation and use of this system.
• Change the disposable fi lter cartridge at the
recommended interval; the disposable fi lter
cartridge MUST be replaced every 6 months
or sooner.
• Failure to replace the disposable fi lter cartridge at
recommended intervals may lead to reduced fi lter
performance and failure of the fi lter, causing
property damage from water leakage or fl ooding.
• Installation and use MUST comply with all state
and local plumbing codes.
• Protect from freezing, remove fi lter cartridge when
temperatures are expected to drop below 33°F
(4.4°C).
• DO NOT install systems in areas where ambient
temperatures may go above 110°F (43.3°C).
• DO NOT install on hot water supply lines. The
maximum operating water temperature of this
fi lter system is 100°F (37.8°C).
• DO NOT install if water pressure exceeds 125 psi
(862 kPa). If your water pressure exceeds 80 psi
(552 kPa), you must install a pressure limiting
valve. Contact plumbing professional if you are
uncertain how to check your water pressure.
• DO NOT install where water hammer conditions
may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a
plumbing professional if you are uncertain how to
check for this condition.
• Where a backfl ow prevention device is installed
on a water system, a device for controlling
pressure due to thermal expansion MUST be
installed. Contact a plumbing professional if you
are uncertain how to select/install/maintain a
thermal expansion device.
2