background image

4

SEITE 4 - 148 x 210 mm  - 44000183283/01 - SCHWARZ  - 12-074 (sr)

Information valid as of January 2012

10.  Return of Old Electric and 

Electronic Equipment for Disposal

10.1 Collection

Users of electric and electronic equipment are required to
collect their old equipment separately from other waste in
accordance with the regulations of the specific country. 
Old electric and electronic equipment must not be disposed
of with unsorted household waste. This separate collection
is a prerequisite for recycling and reprocessing as an
 important method for preserving environmental resources.

10.2  Return and Collection Systems

When your Visio Beta vario is no longer usable, do not
 dispose of the device with household waste. 3M Deutsch -

9.1.4.2  Fill the Unit with Oil

Replace the oil drain screw.

Remove the oil filler screw.

Add oil until the level reaches the upper mark.

Replace the oil filler screw and its seal.

9.1.5 Precautions

•  Used vacuum pump oils from dental laboratories may

contain small quantities of methacrylates/acrylates
which can trigger allergic reactions by skin contact.
To reduce the risk of allergic reactions avoid contact
with these materials.

•  The use of protective gloves (butyl rubber min. 0.5 mm)

and a no-touch technique is recommended. If skin
 contact occurs, wash skin with soap and water.

•  If contact with eyes or prolonged contact with mucous

membranes occur, rinse thoroughly with plenty of water.
If symptoms persist, seek medical attention.

9.2  Maintenance / Repair by 3M

Submissions must include a form “Declaration of
 Contamination 3M ESPE Visio Beta Vacuum Pump” which
has been filled out completely and correctly. The form 
is provided with every pump or can be requested from 3M
as needed.

Before sending the pump, drain the oil and dispose of it

properly.

Fill out the form for the declaration.

WARNING!

Incomplete or incorrect information can result in
hazards for the service personnel!

Provide full and complete information about the
contamination and clean the pump thoroughly
before sending it to 3M.

The user is liable for any consequences  resulting
from an incorrect declaration or a contaminated
pump. The information in the declaration is legally
binding.

land GmbH has set up special disposal facilities to handle
the equipment. Details about the procedure for the specific
country can be obtained from the pertinent 3M subsidiary.

We recommend separated disposal of contaminated
pumps as follows:
•  Pump body, hose lines, and other parts as hazardous

waste (if cleaned, as scrap or household waste);

•  Motor and power line as electrical scrap;
•  Plastics in plastic recycling;
•  Oil in oil recycling.

10.3  Meaning of the Symbols

The EU Directive prohibits the disposal of any electric or 

electronic devices marked with these
symbols in combination with house-
hold waste.

11. Customer Information

No person is authorized to provide any information which
deviates from the information provided in this instruction
sheet.

11.1 Warranty

3M Deutschland GmbH warrants this product will be free
from defects in material and manufacture. 3M Deutschland
GmbH MAKES NO OTHER WARRANTIES INCLUDING ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. User is responsible for
 determining the suitability of the product for user’s applica-
tion. If this product is  defective within the warranty period,
your exclusive remedy and 3M Deutschland GmbH’s sole
obligation shall be repair or replacement of the 3M Deutsch-
land GmbH product.

11.2  Limitation of Liability

Except where prohibited by law, 3M Deutschland GmbH
will not be liable for any loss or damage arising from this
 product, whether direct, indirect, special, incidental or
 consequential, regardless of the theory asserted, including
warranty, contract, negligence or strict liability.

Содержание ESPE Visio Beta

Страница 1: ...Bomba de vac o Bomba de V cuo Vacu mpomp Vakuumpump Tyhj pumppu Vakuumpumpe Vakuumpumpe no da fi sv el nl pt es it fr de en Operating Instructions Bedieningshandleiding Betriebsanleitung Notice d util...

Страница 2: ...nit from being used by another person The safety of the unit can be impaired for example when the unit does not function as indicated or when there is visible damage 1 7 Care must be taken when cleani...

Страница 3: ...rial damage 3 Product Description The Visio Beta vacuum pump is an oil sealed single phase vacuum pump with a rotary valve design intended for use in connection with the Visio Beta vario light curing...

Страница 4: ...k and services may be performed only by 3M ATTENTION Check the oil level at regular intervals 1 Oil filler screw 2 Oil drain screw 3 Oil level sight glass 4 Upper mark MAX 5 Lower mark MIN Check the o...

Страница 5: ...ut the form for the declaration WARNING Incomplete or incorrect information can result in hazards for the service personnel Provide full and complete information about the contamination and clean the...

Страница 6: ...igt ist muss das Ger t au er Betrieb gesetzt und so gekennzeichnet werden dass es nicht aus Versehen von Dritten wieder in Betrieb genommen wird Die Sicherheit kann z B beeintr chtigt sein wenn das Ge...

Страница 7: ...ewicht 10 kg 5 2 Lagerung Die Lagerung erfolgt im staubarmen Innenraum im Temperaturbereich von 5 bis 40 C und einer relativen Luftfeuchtigkeit 90 6 Inbetriebnahme 1 Auspuffstutzen 2 Typenschild 3 lsc...

Страница 8: ...und f r den Anwender zul ssige Arbeiten aus Alle anderen Wartungs oder Serviceleistungen darf nur 3M durchf hren Bei Dauerbetrieb kontinuierliche Nutzung des Visio Beta vario Ger tes ber einen ganzen...

Страница 9: ...ycling l im l Recycling 10 3 Bedeutung der Symbole Alle Elektro und Elektronikger te die mit diesen Symbolen gekennzeichnet sind d rfen gem EU Richtlinie nicht mit dem Hausm ll entsorgt werden 11 Kund...

Страница 10: ...tre per sonne Par exemple la s curit de l appareil peut tre compromise lorsque celui ci ne fonctionne pas comme indiqu ou qu il pr sente des dommages visibles 1 7 Il convient de nettoyer l appareil av...

Страница 11: ...Longueur 323 mm Largeur 132 mm Hauteur 190 mm Poids 10 kg 5 2 Stockage L appareil doit tre d pos l int rieur l abri de la poussi re une temp rature comprise entre 5 et 40 C et un taux d humidit relat...

Страница 12: ...et ne n cessitent donc pas d entretien D terminez les intervalles d entretien en fonction des conditions d utilisation et respectez les Il est conseill d effectuer un entretien toutes les 1000 heures...

Страница 13: ...nts anciens selon les r gles de leur pays Les anciens quipements lectriques et lectroniques ne doivent pas tre jet s avec les d chets m nagers non tri s Ce tri est une n cessit pr alable au recyclage...

Страница 14: ...ziona nella maniera indicata o quando presente un danno evidente 1 7 Accertarsi che nel corso delle operazioni di pulizia nell unit non entrino detergenti liquidi potrebbero derivarne cortocircuiti o...

Страница 15: ...bbrica di una protezione termica contro i sovraccarichi che protegge dal danneggiamento o distruzione il motore e la pompa di aspirazione La pompa di aspirazione viene fornita con un olio speciale e p...

Страница 16: ...ento sono lubrificati permanentemente e quindi non richiedono manutenzione Stabilire ed eseguire gli intervalli di manutenzione secondo le condizioni d uso presenti Consigliamo di eseguire la manutenz...

Страница 17: ...in vigore nel relativo paese sono disponibili presso la sede competente di 3M Per le pompe contaminate si consiglia lo smaltimento separato nel modo seguente corpo della pompa tubi ed altre parti come...

Страница 18: ...ilice otra persona La unidad puede dejar de ser segura por ejemplo si no funciona tal como se indica o si se observan en ella desperfectos visibles 1 7 Tenga cuidado al limpiarla para asegurarse de qu...

Страница 19: ...isio Beta vario Est equipada de f brica con un protector t rmico de sobrecarga que protege al motor y a la bomba contra los da os o la destrucci n La bomba de vac o se suministra con un aceite especia...

Страница 20: ...intervalos de mantenimiento de acuerdo con las condiciones de aplicaci n existentes y ll velos a cabo consecuentemente Recomendamos realizar el mantenimiento cada 1000 horas de funcionamiento 9 1 1 Co...

Страница 21: ...o por ejemplo a da os sufridos durante el almacenamiento a un manejo inadecuado por negligencia o actos vand licos Cualquier reclamaci n interpuesta a tenor de lo dispuesto en la presente garant a ser...

Страница 22: ...sligada e etiquetada por forma a prevenir a sua utiliza o por outra pessoa A seguran a da unidade por estar comprometida por exemplo quando a unidade n o se encontrar a funcionar da forma indicada ou...

Страница 23: ...ngueira e deitar fora Encaixar ambas as mangueiras fornecidas nas mangas da bomba e fixar com as respectivas bra adeiras 1 Manga de escape 2 Placa de caracter sticas 3 Indicador de n vel de leo 4 Buj...

Страница 24: ...t que seja atingida a marca o superior Voltar a enroscar o tamp o de abastecimento de leo com a respectiva veda o ATEN O Realize apenas os trabalhos descritos e autoriza dos ao utilizador Todos os out...

Страница 25: ...ra o respectivo pa s em quest o junto da filial 3M respons vel Para casos de bombas contaminadas recomenda se uma elimina o separada do seguinte modo Corpo da bomba mangueiras e outras componentes com...

Страница 26: ...omen dat anderen deze eenheid gebruiken De eenheid is bijvoorbeeld niet langer veilig als deze niet werkt zoals aangegeven of als er zichtbare schade is 1 7 Tijdens het reinigen dient ervoor te worden...

Страница 27: ...ar Olievulling 0 5 l Afmetingen Lengte 323 mm Breedte 132 mm Hoogte 190 mm Gewicht 10 kg 5 2 Opslag De opslag gebeurt in een stofarme binnenruimte in het temperatuurbereik van 5 tot 40 C en een relati...

Страница 28: ...levensduur gesmeerd en daarmee onderhoudsvrij De onderhoudsintervallen in overeenstemming met de beschikbare inzetvoorwaarde vastleggen en uitvoeren Wij raden aan het onderhoud iedere1000 bedrijfsuren...

Страница 29: ...araten mogen niet samen met het ongesorteerde huisvuil worden afgevoerd Het gescheiden inzamelen is een voorwaarde voor de recycling en het her gebruik waardoor de bronnen en het milieu worden ontzien...

Страница 30: ...3M ESPE 7 7 1 6 1 7 7 7 1 8 1 9 1 10 VGB16 1 11 Visio Beta el 29 1 29 2 30 3 30 4 30 5 30 5 1 30 5 2 30 6 30 6 1 30 6 2 31 7 31 8 7 31 9 31 9 1 31 9 1 1 A 31 9 1 2 31 9 1 3 A 31 9 1 4 31 9 1 4 1 31 9...

Страница 31: ...r 1 12 7 7 1 13 7 60 75 C 140 167 F 2 3 Visio Beta Visio Beta vario Visio Beta vario 4 Visio Beta vario 5 5 1 120 V 230 V 50 60 Hz 180 W 4 m 3 h 10 1 mbar 0 5 l 323 mm 132 mm G 190 mm 10 kg 5 2 7 5 40...

Страница 32: ...SCHWARZ 12 074 sr el Visio Beta vario 6 2 7 Visio Beta vario 7 Visio Beta vario Visio Beta vario 8 7 9 9 1 7 1000 7 9 1 1 0 0 0 0 0 3M 0 1 2 3 4 J MAX 5 MIN 9 1 3 7 7 7 9 1 4 Visio Beta vario 9 1 4 1...

Страница 33: ...9 1 5 0 7 7 7 0 5 9 2 3M 3M ESPE Visio Beta 3M 7 10 2 Visio Beta vario 3M Deutschland GmbH 3M 7 7 7 7 7 7 7 7 10 3 11 7 11 1 3M Deutschland GmbH 7 7 3M Deutschland GmbH Q 3M Deutschland GmbH 3M Deuts...

Страница 34: ...reng ring av enheten s att inga reng ringsmedel kommer in i enheten eftersom detta kan orsaka kortslutning eller farliga tekniska fel 1 8 Enheten f r endast ppnas och repareras av kvalificerad teknik...

Страница 35: ...Fara som kan medf ra sv ra person eller sakskador 1 Utbl sningsf rbindelse 2 Typskylt 3 Oljeniv glas 4 Oljeavtappningsskruv 5 Drivmotor 6 Insugsf rbindelse 7 F rslutningsskruv f r oljep fyllning OBS...

Страница 36: ...uell anv ndning Vi rekommenderar att underh ll genomf rs efter 1000 driftstimmar 9 1 1 vervaka oljeniv n OBS Genomf r endast beskrivna och f r anv ndare till tna arbeten Alla andra underh lls eller se...

Страница 37: ...inte l mnas tillsammas med vriga hush llssopor Att samla in dessa produkter separat r en f ruts ttning f r tervinning och god resurshush llning 10 2 terl mnings och insamlingssystem N r du har skrotat...

Страница 38: ...sasi laitetta ettei laitteeseen p se puhdistusnesteit Puhdistusnesteet voivat aiheuttaa oikosulkuja ja toimintavikoja 1 8 Vain ammattiasentaja saa avata laitteen ja korjata sen 1 9 l altista laitetta...

Страница 39: ...u toimitetaan erikois ljyn kanssa ja sit saa k ytt vain t ll ljyll 1 Poistoistukka 2 Tyyppikilpi 3 ljynmittalasi 4 ljynpoistoruuvi 5 K ytt moottori 6 Imuistukka 7 ljynt yt n sulkuruuvi HUOMIO Liitosle...

Страница 40: ...an laitteen 1000 k ytt tunnin v lein 9 1 1 ljytason tarkkailu HUOMIO Suorita vain ohjeessa kuvatut ja k ytt j lle sallitut ty t Kaikki muut huolto ja kunnossapitotoimet on annettava 3M n suoritettavak...

Страница 41: ...rr tyksen ja j lleenk sittelyn edellytyksen on lajittelu mink ansiosta ymp rist s stet n 10 2 Palautus ja ker ysj rjestelm t Kun hankkimasi Visio Beta vario poistetaan k yt st laitetta ei saa h vitt k...

Страница 42: ...ke uforvarende tager det i brug Sikkerheden kan fx v re forringet hvis apparatet ikke fungerer som foreskrevet eller der forekommer synlige skader 1 7 Ved reng ring skal der udvises forsigtighed s det...

Страница 43: ...lamelpumpe konstruktion beregnet for tilslutning til Visio Beta vario lysh rdningslampen Vacuumpumpen er fra fabrikkens side udstyret med en termisk overbelastningssikring der beskytter motor og vakuu...

Страница 44: ...af hvor hyppigt apparatet anvendes Vi anbefaler vedligeholdelse efter hver 1000 driftstimer 9 1 1 Oliestand kontrol OBS Udf r kun de if lge betjeningsvejledningen foreskrevne arbejder som er tilladt f...

Страница 45: ...m ikke bortskaffes sammen med almindeligt husholdningsaf fald Den separate indsamling er en foruds tning for recy cling og genanvendelse hvilket sk ner milj et 10 2 Tilbageleverings og opsamlingssyste...

Страница 46: ...vises ved rengj ring slik at det ikke siver inn rengj ringsv sker i enheten Det kan f re til kortslutting eller farlige funksjonsfeil 1 8 Bare en kvalifisert tekniker b r pne og utf re reparasjoner p...

Страница 47: ...mot skader eller deleggelse Vakuumpumpen leveres med en spesiell olje og m kun brukes med denne oljen 1 Avgasstuss 2 Typeskilt 3 Oljeniv glass 4 Oljeplugg 5 Drivmotor 6 Sugestuss 7 L seskrue for oljep...

Страница 48: ...ds og serviceoppgaver m kun gjennomf res av 3M OBS Kontroller oljeniv et regelmessig 1 Oljep fyllingsskrue 2 Oljet mmingsskrue 3 Oljeniv glass 4 vre markering MAKS 5 Nedre markering MIN 9 1 3 Oljekont...

Страница 49: ...sortert husholdningsavfall En separat innsamling er en forutsetning for resirkulering og gjenbruk som en viktig metode for bevaring av milj ressursene 10 2 Innleverings og sorteringssystemer N r din d...

Страница 50: ...Deutschland GmbH 3M ESPE Dental Products Dental Products Carl Schurz Str 1 St Paul MN 55144 1000 U S A 41453 Neuss Germany 3M and ESPE are trademarks of 3M Company or 3M Deutschland GmbH Used under li...

Отзывы: