Cartridge Model
Flush Instructions
PS114*, PS124*, P124BN*, P165BN*,
P195BN*
Flush 2.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF05-MS*
Flush 1.5 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF10-MS*, HF15-MS*
Flush 2.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF20-S*, HF20-MS*, HF25-S*,
HF25-MS*
Flush 3.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF20-I, HF20-SI
Flush 3.34 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF25-S-SR, HF20-A020-SR,
HF20-S-SR, HF20-A020-S-SR
Flush 4.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF30*, HF30-MS*, HF35-CL*, HF35*,
HF35-MS*
Flush 3.5 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF40*, HF40-S*, HF45*, HF45-S*,
160-L*
Flush 4.2 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF40-S-SR
Flush 5.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF45-S-SR
Flush 7.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF60*, HF60-S*, HF60-S-SR,
HF60-S-SR5, HF65*, HF65-S*,
HF60-A020-S-SR
Flush 7.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF60-CL*, HF60-CLS*
Flush 4.5 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF65-CL*
Flush 4.2 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF65-S-SR, HF65-S-SR5
Flush 10.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF90*, HF90-S*, HF90-S-SR, HF90-SR,
HF95*, HF95-S*, HF95-CL*
Flush 10.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
HF95-S-SR
Flush 14.0 gals through cartridge(s)
before use (flush approx. 2 mins.)
System Tested and Certified by NSF International against Std 42, Std 53 and/or CSA B483.1
for the reduction of claims listed on the Performance Data Sheet.
Note: Models PS114, PS124, P124BN, P165BN, and P195BN are not Certified by NSF International.
Flush Table
This model is certified by the
Water Quality Association to
WQA/ASPE/ANSI S-803