DF260-CL-CC System Pre-Start-Up procedure:
1. Turn ice water inlet valve ON.
2. Remove trap air in the ice line by opening and closing the ice outlet fl ush valve.
3. Turn ice water outlet valve ON.
4. Turn beverage/coffee water inlet valve ON.
5. Remove trap air in the beverage line by opening and closing the beverage outlet fl ush valve.
6. Turn beverage water outlet valve ON.
7. Turn coffee water outlet valve ON
8. Slowly turn the beverage/coffee inlet water valve ON and check for leaks.
9. Slowly turn the ice inlet water valve ON and check for leaks.
10. Flush per the cartridge Performance Data Sheet and check for leaks. System is now ready for use.
Troubleshooting
No water fl ow through system
Inlet valve closed
Cartridges clogged
Check shut-off valve position
Replace cartridges
Not enough water to the
downsteam application(s)
Low incoming water pressure
Cartridges clogged
Check source
Replace cartridges
Short fi lter life
Temporarily dirty water
Change cartridges or install an
additional upstream prefi lter