IMPORTANT NOTES

IMPORTANT NOTES

•  Failure to follow instructions will void warranty.

•  Allow a minimum of 3" (7.6 cm) clear space under fi lter to facilitate cartridge change.

•  Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.

•  Some local codes may require the use of a licensed plumber or certifi ed installer when disrupting a potable water line.

CAUTION

CAUTION

To reduce the risk associated with property damage due to water leakage:

• 

Read and follow

 Use Instructions before installation and use of this system.

•  Installation and use 

MUST

 comply with all state and local plumbing codes.

•  Before starting installation, shut off main water supply and drain pipes.

• 

Protect from freezing

, remove fi lter cartridge when temperatures are expected to drop below 40 °F (4.4 °C).

• 

Do not

 install systems in areas where ambient temperatures may go above 110 °F (43.3 °C).

• 

Do not install on hot water supply lines.

 The maximum operating water temperature of this system is 100 °F (37.8 °C).

• 

Do not

 install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa), you must install a pressure 

limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

• 

Do not install

 where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact 

a plumbing professional if you are uncertain how to check for this condition.

•  Any non-metallic fi ttings used in the installations must be of adequate rating for the line pressure.

•  Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed.

• 

Do not

 use a torch or other high temperature sources near system, cartridges, plastic fi ttings or plastic plumbing.

•  On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape 

only

, pipe dope properties may deteriorate plastic.

•  Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if over tightening occurs.

• 

Do not install

 in direct sunlight or outdoors.

• 

Do not install

 near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.

•  Mount system in such a position as to prevent it from being struck by other items used in the area of installation.

•  Ensure that the location and fasteners will support the weight of the system when installed and full of water.

•  Ensure all tubing and fi ttings are secure and free of leaks.

• 

Do not install

 unit if collet is missing. Contact your sales representative if collets are missing from any fi ttings.

•  The disposable fi lter cartridge(s) MUST be replaced every 12 months, at the rated capacity, or sooner if a noticeable drop in pressure occurs.

2

Содержание DF260-CL-CC

Страница 1: ...his manual with owner operator Owner Operator Please retain for operation and future instructions 3M Water Filtration Products Installation and Operation Instructions for High Flow Series Dual Flow Manifold System DF260 CL CC ...

Страница 2: ...NOTES ...

Страница 3: ...ry and or property damage CAUTION CAUTION Indicates a potentially hazardous situation which if not avoided may result in property damage WARNING WARNING To reduce the risk associated with the ingestion of contaminants Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used...

Страница 4: ...f water hammer conditions exist you must install a water hammer arrester Contact a plumbing professional if you are uncertain how to check for this condition Any non metallic fittings used in the installations must be of adequate rating for the line pressure Where a backflow prevention device is installed on a water system a device for controlling pressure due to thermal expansion must be installe...

Страница 5: ...ridge is a pleated nylon membrane with a time released scale inhibitor It filters the water going to the ice machine The water for the ice machine exits the manifold on the left side front connection labeled Outlet Ice The two cartridges to the right of the ice cartridge blue label are model HF60 CL These cartridges are plumbed in parallel and filter the water going to post mix cold beverage and c...

Страница 6: ... the leak from its push in connector Cut off at least 1 4 0 6 cm from the end Reattach the tubing to its push in connector Confirm connection is leak free How to Use the Inlet Outlet Fitting Retention Clips This product is outfitted with inlet outlet fittings The fittings can be attached or removed from the system without tools Retention clips are semi circular in shape with three internal tabs bo...

Страница 7: ...e fasteners 5 Install NPT male inlet fittings for the ice water inlet and the beverage coffee water inlet left and right rear respectively Install a Barb fitting for the ice water outlet a Barb fitting for the beverage water outlet and a NPT female fitting for the coffee water outlet left middle and right front respectively The inlet Connection Kit CCP 125830 includes the Barb fittings and the two...

Страница 8: ...utlet flush valve 2 Push and hold yellow tab to release cartridge locking mechanism while simultaneously rotating cartridge to the left 3 Using both hands and holding the cartridge from the bottom rotate the cartridge a quarter turn to the left and gently pull down NOTE A small amount of water will drain from manifold as cartridge is removed 4 Remove sanitary cap from new cartridge Install with a ...

Страница 9: ... ON 8 Slowly turn the beverage coffee inlet water valve ON and check for leaks 9 Slowly turn the ice inlet water valve ON and check for leaks 10 Flush per the cartridge Performance Data Sheet and check for leaks System is now ready for use Troubleshooting No water flow through system Inlet valve closed Cartridges clogged Check shut off valve position Replace cartridges Not enough water to the down...

Страница 10: ...roduct fails to satisfy this Limited Warranty during the warranty period 3M Purification Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from stat...

Страница 11: ...can affect the performance of the Product s in a particular application some of which are uniquely within your knowledge and control INFORMATION IS SUPPLIED UPON THE CONDITION THAT THE PERSONS RECEIVING THE SAME WILL MAKE THEIR OWN DETERMINATION AS TO ITS SUITABILITY FOR THEIR USE IN NO EVENT WILL 3M PURIFICATION INC BE RESPONSIBLE FOR DAMAGES OF ANY NATURE WHATSOEVER RESULTING FROM THE USE OF OR ...

Отзывы: