background image

Cartridge Change-out Procedure

CAUTION

To reduce the risk associated with property damage due to water leakage:

• The disposable fi lter cartridge 

MUST

 be replaced every 12 months or sooner at the rated capacity or if a noticeable reduction in fl ow rate occurs.

IMPORTANT NOTE:

The ice cartridge (Model HF60-S-SR5) has a yellow label and will only fi t into the head on the left side of the manifold (head has a yellow 3M label). 
The Beverage cartridges (Model HF60-CL) will only fi t into the heads on the right side of the manifold (heads have a blue 3M label).

DF260-CL-CC System Shut-Off procedure:

Cartridges will need to be changed at least every 12 months or when low pressure is indicated on the manifold’s pressure gauge, whichever 
occurs fi rst. Depending on local water quality, you may need to change the cartridges prior to the recommended change-out. The loss of fl ow to 
carbonators or improper fi ll at the ice maker are also indicators that the cartridges will need to be replaced.

1.  Shut-off ice, beverage, and coffee water inlet valves (2 total).

2.  Shut-off ice, beverage, and coffee water outlet valves (3 total). 

3.  Replace HF60-S-SR5 (yellow label), HF60-CL (blue label), and HF8-S cartridges in the sequence shown below.  Then complete DF260-CL-

CC System Pre-Start-Up procedure as shown below before starting system back up. 

HF60-S-SR5 Cartridge (yellow label) Replacement:

1.  Relieve pressure in the ice line by opening and closing the ice outlet fl ush valve. 

2.  Push and hold yellow tab to release cartridge locking mechanism while simultaneously rotating cartridge to the left.

3.  Using both hands and holding the cartridge from the bottom, rotate the cartridge a quarter turn to the left and gently pull down. NOTE: A 

small amount of water will drain from manifold as cartridge is removed.

4.  Remove sanitary cap from new cartridge. Install with a quarter turn to the right until cartridge comes to a complete stop. NOTE: Cartridges 

are keyed to fi t in proper location only.  

HF60-CL Cartridge (blue label) Replacement:

1.  Relieve pressure to beverage/coffee line by opening and closing the fl ush valve in between the HF60-CL cartridges.   

2.  Push and hold yellow tab to release cartridge locking mechanism while simultaneously rotating cartridge to the left.

3.  Using both hands and holding the cartridge from the bottom, rotate the cartridge a quarter turn to the left and gently pull down. NOTE: A 

small amount of water will drain from manifold as cartridge is removed.

4.  Remove sanitary cap from new cartridge. Install with a quarter turn to the right until cartridge come to a complete stop. NOTE: Cartridges 

are keyed to fi t in proper location only.  

5.  Repeat steps 2-4 for second HF60-CL cartridge

HF8-S Cartridge Replacement:

1.  Open downstream valve to relieve pressure.

2.  Unscrew cartridge by turning clockwise. NOTE: A small amount of water will drain when HF8-S cartridge is removed.

3.  Lubricate o-ring of new cartridge with water. 

4.  Install by turning new HF8-S cartridge toward the right until it come to a complete stop.  Do not over tighten. (never use tools to tighten 

cartridge)

6

Содержание DF260-CL-CC

Страница 1: ...his manual with owner operator Owner Operator Please retain for operation and future instructions 3M Water Filtration Products Installation and Operation Instructions for High Flow Series Dual Flow Manifold System DF260 CL CC ...

Страница 2: ...NOTES ...

Страница 3: ...ry and or property damage CAUTION CAUTION Indicates a potentially hazardous situation which if not avoided may result in property damage WARNING WARNING To reduce the risk associated with the ingestion of contaminants Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used...

Страница 4: ...f water hammer conditions exist you must install a water hammer arrester Contact a plumbing professional if you are uncertain how to check for this condition Any non metallic fittings used in the installations must be of adequate rating for the line pressure Where a backflow prevention device is installed on a water system a device for controlling pressure due to thermal expansion must be installe...

Страница 5: ...ridge is a pleated nylon membrane with a time released scale inhibitor It filters the water going to the ice machine The water for the ice machine exits the manifold on the left side front connection labeled Outlet Ice The two cartridges to the right of the ice cartridge blue label are model HF60 CL These cartridges are plumbed in parallel and filter the water going to post mix cold beverage and c...

Страница 6: ... the leak from its push in connector Cut off at least 1 4 0 6 cm from the end Reattach the tubing to its push in connector Confirm connection is leak free How to Use the Inlet Outlet Fitting Retention Clips This product is outfitted with inlet outlet fittings The fittings can be attached or removed from the system without tools Retention clips are semi circular in shape with three internal tabs bo...

Страница 7: ...e fasteners 5 Install NPT male inlet fittings for the ice water inlet and the beverage coffee water inlet left and right rear respectively Install a Barb fitting for the ice water outlet a Barb fitting for the beverage water outlet and a NPT female fitting for the coffee water outlet left middle and right front respectively The inlet Connection Kit CCP 125830 includes the Barb fittings and the two...

Страница 8: ...utlet flush valve 2 Push and hold yellow tab to release cartridge locking mechanism while simultaneously rotating cartridge to the left 3 Using both hands and holding the cartridge from the bottom rotate the cartridge a quarter turn to the left and gently pull down NOTE A small amount of water will drain from manifold as cartridge is removed 4 Remove sanitary cap from new cartridge Install with a ...

Страница 9: ... ON 8 Slowly turn the beverage coffee inlet water valve ON and check for leaks 9 Slowly turn the ice inlet water valve ON and check for leaks 10 Flush per the cartridge Performance Data Sheet and check for leaks System is now ready for use Troubleshooting No water flow through system Inlet valve closed Cartridges clogged Check shut off valve position Replace cartridges Not enough water to the down...

Страница 10: ...roduct fails to satisfy this Limited Warranty during the warranty period 3M Purification Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from stat...

Страница 11: ...can affect the performance of the Product s in a particular application some of which are uniquely within your knowledge and control INFORMATION IS SUPPLIED UPON THE CONDITION THAT THE PERSONS RECEIVING THE SAME WILL MAKE THEIR OWN DETERMINATION AS TO ITS SUITABILITY FOR THEIR USE IN NO EVENT WILL 3M PURIFICATION INC BE RESPONSIBLE FOR DAMAGES OF ANY NATURE WHATSOEVER RESULTING FROM THE USE OF OR ...

Отзывы: