17

2.0  System Use

2.1 

FALL PROTECTION AND RESCUE PLAN:

 The employer must have a Fall Protection and Rescue Plan. The plan should 

provide guidelines and requirements for an employer’s managed fall protection program, including policies, duties and 

training; fall protection procedures; eliminating and controlling fall hazards; rescue procedures; incident investigations; 

and evaluating program effectiveness.

2.2 

INSPECTION FREQUENCY:

 

SRDs shall be inspected by the authorized person

1

 or rescuer

2

 before each use (See Table 

3). Additionally, inspections shall be conducted by a competent person

3

 other than the user. Extreme working conditions 

(harsh environment, prolonged use, etc.) may necessitate more frequent competent person inspections. The competent 

person shall use the 

Inspection Schedule (Table 2)

 to determine appropriate inspection intervals. Inspection procedures 

are described in the 

Inspection & Maintenance Log (Table 3)

. Results of the Competent Person inspection should be recorded 

in the 

Inspection and Maintenance Log 

or recorded with the Radio Frequency Identification (RFID) system (see 

Section 5

).

2.3 

NORMAL OPERATIONS:

 Normal operation will allow the lifeline to extend and retract with no hesitation or slack as 

the worker moves at normal speeds. If a fall occurs, a speed sensing brake system will activate, stopping the fall and 

absorbing much of the energy created. Sudden or quick movements should be avoided during normal work operation, as 

this may cause the SRD to lock up. For falls which occur near the end of the lifeline travel, a reserve lifeline system or 

Energy Absorber has been incorporated to reduce the fall arrest forces.

2.4 

BODY SUPPORT:

 A Full Body Harness must be used with the Self-Retracting Device. The harness connection point must be 

above the user’s center of gravity. A body belt is not authorized for use with the Self-Retracting Device. If a fall occurs when 

using a body belt it may cause unintentional release or physical trauma from improper body support.

2.5 

COMPATIBILITY OF COMPONENTS:

 Unless otherwise noted, 3M equipment is designed for use with 3M approved 

components and subsystems only. Substitutions or replacements made with non approved components or subsystems may 

jeopardize compatibility of equipment and may affect safety and reliability of the complete system.

2.6 

COMPATIBILITY OF CONNECTORS:

 Connectors are considered to be compatible with connecting elements when they 

have been designed to work together in such a way that their sizes and shapes do not cause their gate mechanisms to 

inadvertently open regardless of how they become oriented. Contact 3M if you have any questions about compatibility. 

Connectors (hooks, carabiners, and D-rings) must be capable of supporting at least 22.2 kN (5,000 lbs). Connectors 

must be compatible with the anchorage or other system components. Do not use equipment that is not compatible. 

Non-compatible connectors may unintentionally disengage (see Figure 5). Connectors must be compatible in size, shape, 

and strength. Self-locking snap hooks and carabiners are required. If the connecting element to which a snap hook or 

carabiner attaches is undersized or irregular in shape, a situation could occur where the connecting element applies a 

force to the gate of the snap hook or carabiner (A). This force may cause the gate to open (B), allowing the snap hook or 

carabiner to disengage from the connecting point (C).

2.7 

MAKING CONNECTIONS:

 Snap hooks and carabiners used with this equipment must be self-locking. Ensure all 

connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all 

connectors are fully closed and locked. 3M connectors (snap hooks and carabiners) are designed to be used only as 

specified in each product’s user’s instructions. See Figure 6 for examples of inappropriate connections. 

 

Do not connect snap hooks and carabiners

:

A.  To a D-ring to which another connector is attached.
B.  In a manner that would result in a load on the gate. Large throat snap hooks should not be connected to standard 

size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists or rotates, unless the 

snap hook is equipped with a 16 kN (3,600 lb) gate.

C. 

In a false engagement, where size or shape of the mating connectors are not compatible and, without visual 

confirmation, the connectors seem fully engaged.

D.  To each other.
E.  Directly to webbing or rope lanyard or tie-back (unless the manufacturer’s instructions for both the lanyard and 

connector specifically allows such a connection).

F.  To any object which is shaped or dimensioned such that the snap hook or carabiner will not close and lock, or that 

roll-out could occur.

G.  In a manner that does not allow the connector to align properly while under load.

Table 2  –  Inspection Schedule

Type of Use

Application Examples

Conditions of Use

Inspection Frequency

Competent Person

Infrequent to Light

Rescue and Confined Space, 

Factory Maintenance

Good Storage Conditions, Indoor or Infrequent 

Outdoor Use, Room Temperature, Clean Environments

Annually

Moderate to Heavy

Transportation, Residential 

Construction, Utilities, Warehouse

Fair Storage Conditions, Indoor and Extended Outdoor 

Use, All Temperatures, Clean or Dusty Environments

Semi-Annually to 

Annually

Severe to Continuous

Commercial Construction, Oil and 

Gas, Mining

Harsh Storage Conditions, Prolonged or Continuous 

Outdoor Use, All Temperatures, Dirty Environment

Quarterly to Semi-

Annually

1  Authorized Person:

 A person assigned by the employer to perform duties at a location where the person will be exposed to a fall hazard.

2 Rescuer:

 Person or persons other than the rescue subject acting to perform an assisted rescue by operation of a rescue system.

3  Competent Person:

 An individual designated by the employer to be responsible for the immediate supervision, implementation, and monitoring of the employer’s 

managed fall protection program who, through training and knowledge, is capable of identifying, evaluating, and addressing existing and potential fall hazards, and 

who has the employer’s authority to take prompt corrective action with regard to such hazards.

Содержание DBI SALA Nano-Lok

Страница 1: ... 140 kg 310lbs 3101316 2 1 2 2 m 6 6 ft 140 kg 310lbs 3101718 2 1 2 2 m 6 6 ft 140 kg 310lbs 3101719 2 1 2 2 m 6 6 ft 140 kg 310lbs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 EN360 2002 Regulation EU 2016 425 Regulation 2016 425 on Personal Protective Equipment as amended to apply in GB CE Type Test No 2797 BSI The Netherlands B V Say Building John M Keynesplein 9 1066 EP Amsterdam Netherlands CE Production...

Страница 2: ...3 2 E D C A B G F C A B D H C A B B A C D h 3 A B FC FF DD SF FC FF DD SF C FC H ...

Страница 3: ...8 ft 2 0 m 6 6 ft 2 8 m 9 3 ft 1 5 m 5 ft 3 3 m 10 7 ft 3 9 m 12 8 ft 4 4 m 14 4 ft FC 59 kg to 100 kg R TM 2 5 m 8 3 ft 2 1 m 6 9 ft 2 9 m 9 5 ft 1 8 m 5 8 ft 3 5 m 11 3 ft FC 4 1 m 13 6 ft 4 9 m 16 1 ft m ft 0 3 1 0 6 2 0 9 3 1 2 4 1 5 5 0 3 1 0 6 2 0 9 3 1 2 4 m ft 0 3 1 0 6 2 0 9 3 1 2 4 1 5 5 0 3 1 0 6 2 0 9 3 1 2 4 1 5 5 100 kg to 140 kg x 1 100 kg 140 kg H V ...

Страница 4: ...5 5 6 A B C A B C D E F G 7 8 ...

Страница 5: ...6 9 1 A B B A Delta III ExoFit NEX 2 C C D 3 4 5 A D A ...

Страница 6: ...7 10 1 A B 2 C D D 3 F G E 4 A E 5 F E 6 A D C ...

Страница 7: ...8 11 1 2 3 4 5 6 7 ...

Страница 8: ...9 12 1 B A 2 D E C 3 H F G 4 5 6 J K 13 1 2 ...

Страница 9: ...10 13 3 4 5 14 E D A G D B F C F ...

Страница 10: ...11 15 16 A B C 17 18 19 20 21 A E B C A E B D A A B B C A B C D B A C ...

Страница 11: ...12 22 A C A B C D B D ...

Страница 12: ... the SRD Avoid sudden or quick movements during normal work operation This may cause the device to lock up Ensure that fall protection systems subsystems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent and ...

Страница 13: ...abiner Steel 19 mm 3 4 in 16 kN 3600 lbs 22 2 kN 5000 lbs 4 Single SRD Interface Steel 51 mm 2 in 16 kN 3600 lbs 22 2 kN 5000 lbs 5 Twin SRD Interface Steel w Nylon Insert 19 mm 3 4 in 16 kN 3 600 lbs 22 2 kN 5000 lbs 6 Carabiner Aluminum Steel 56 mm 2 19 in 16 kN 3600 lbs 22 2 kN 5000 lbs 7 Carabiner Aluminum 19 mm 3 4 in 16 kN 3600 lbs 22 2 kN 5000 lbs 8 Rebar Hook Aluminum 57 mm 2 1 4 in 1 kN 2...

Страница 14: ...iking an object in a swing fall may cause serious injury see Figure 3A Minimize swing falls by working as directly below the anchorage point as possible Figure 3B Working away from the anchorage point Figure 3C will increase the impact of a swing fall and increase the required Fall Clearance FC Fall Clearance Figure 3B illustrates Fall Clearance Calculation Fall Clearance FC is the sum of Free Fal...

Страница 15: ...compatible in size shape and strength Self locking snap hooks and carabiners are required If the connecting element to which a snap hook or carabiner attaches is undersized or irregular in shape a situation could occur where the connecting element applies a force to the gate of the snap hook or carabiner A This force may cause the gate to open B allowing the snap hook or carabiner to disengage fro...

Страница 16: ...ivel Eye on the SRD E Thread the Interface through the Swivel Eyes so the SRD hangs from the backbone of the Harness Interface F 4 Position the Harness Interface around the Web Straps Position the open gate of the Harness Interface around the loose Web Straps A 5 Close the Harness Interface Push the Harness Interface Locking Pin D through the loose Web Straps A until it locks in place in the oppos...

Страница 17: ...the Connector behind the Web Straps until the Connector surrounds the the Web Straps 5 Add the second Nano Lok SRD on the Twin Carabiner Slide the SRL s Swivel Eye G over the nose of the Connector F and position the SRL Swivel Eye in the nose end of the Connector F Swing the Gate E closed 6 Close the Twin Carabiner Rotate the Connector Insert C forward so the Clamps D secure on the Connector When ...

Страница 18: ...ch connection location must independently support 2 248 lbs 10 kN or be an engineered system as with a Horizontal Lifeline Never connect more than one person at a time to the Twin SRD system Figure 16C Do not allow the Lanyards to become tangled or twisted together as this may prevent them from retracting Do not allow any lanyard to pass under arms or between legs during use 4 7 TWIN SRD DORSAL D ...

Страница 19: ...ldup of dirt paint etc may prevent the lifeline from fully retracting back into the housing causing a potential free fall hazard 6 2 SERVICE SRDs are not repairable If the SRD has been subjected to fall force or inspection reveals an unsafe or defective condition remove the SRD from service and discard see Disposal 6 3 STORAGE TRANSPORT Store and transport SRDs in a cool dry clean environment out ...

Страница 20: ...ooks Interfaces etc for signs of damage corrosion and proper working condition Where present Gates should open close lock and unlock properly and Locking Buttons and Locking Pins should function correctly Web Lifeline Figure 20 Inspect webbing material must be free of cuts A frays B or broken fibers Check for tears abrasions heavy soiling C mold burns D or discoloration Inspect stitching Check for...

Страница 21: ...a eller snabba rörelser under normalt arbete Dessa kan få enheten att låsa sig Se till att fallskyddssystem och delsystem som är monterade med komponenter från olika tillverkare är kompatibla och uppfyller kraven i tillämpliga standarder inklusive ANSI Z359 eller andra tillämpliga regler standarder eller krav på fallskydd Rådgör alltid med en kompetent eller kvalificerad person före användning av ...

Страница 22: ...ok Stål 19 mm 3 4 tum 16 kN 3 600 lb 22 2 kN 5 000 lb 4 Enkel SRL länk Stål 51 mm 2 tum 16 kN 3 600 lb 22 2 kN 5 000 lb 5 Dubbel SRL länk Stål med nyloninlägg 19 mm 3 4 tum 16 kN 3 600 lb 22 2 kN 5 000 lb 6 Karbinkrok Aluminium stål 56 mm 2 19 tum 16 kN 3 600 lb 22 2 kN 5 000 lb 7 Karbinkrok Aluminium 19 mm 3 4 tum 16 kN 3 600 lb 22 2 kN 5 000 lb 8 Armeringsjärnkrok Aluminium 57 mm 2 1 4 tum 1 kN ...

Страница 23: ...en inte befinner sig rakt ovanför användaren Kraften av en träff mot ett föremål i ett pendelfall kan orsaka allvarliga personskador se figur 3A Minimera risken vid pendelfall genom att arbeta med förankringspunkten så rakt ovanför dig som möjligt figur 3B Konsekvenserna av ett pendelfall och fallmarginalen FC blir större med ökande avstånd mellan användaren och förankringspunkten Figur 3C Fallmar...

Страница 24: ...tomatkrokar och karbinkrokar krävs Om ett kopplingselement som en automatkrok eller karbinkrok fästs i är underdimensionerat eller har felaktig form kan en situation uppstå där kopplingselementet anbringar en kraft på automatkrokens eller karbinkrokens A öppningsmekanism Denna kraft kan orsaka att öppningsmekanismen öppnas B vilket medför att automatkroken eller karbinkroken kan lossna från koppli...

Страница 25: ... låstappen D 3 Sätta fast SRL blocket på SRL länken För in SRL länkens öppna låsmekanism genom den roterande öglan på SRL blocket E Trä SRL länken genom de roterande öglorna så att SRL blocket hänger i selens ryggplatta F 4 Placera SRL länken omkring vävstropparna Placera SRL länkens öppningsmekanism omkring de lösa vävstropparna A 5 Stäng selens SRL länk Tryck SRL länkens låssprint D genom de lös...

Страница 26: ...omsluter dem Med öppningsmekanismen vänd uppåt för in kopplingens spets F bakom vävstropparna A Vrid kopplingen bakom vävstropparna tills kopplingen omger vävstropparna 5 Lägg till det andra Nano Lok SRL blocket på den dubbla karbinkroken Skjut SRL blockets svivelögla G över kopplingens spets F och placera SRL blockets svivelögla vid kopplingens spets F Vrid öppningsmekanismen E till stängt läge 6...

Страница 27: ...ras därför inte Anslutning av varje SRD ben till separata förankringspunkter på olika höjder krävs Figur 16B Varje kopplingspunkt måste oberoende av varandra klara 10 kN 2 248 lb eller vara ett specialkonstruerat system t ex en horisontell livlina Koppla aldrig mer än en person samtidigt till ett system med dubbla SRL block Figur 16C Låt inte livlinorna trassla in sig i varandra eftersom det kan h...

Страница 28: ...ras in helt och orsaka risk för fritt fall 6 2 SERVICE SRL block kan inte repareras Ett SRL block som har utsatts för fallstoppkraft eller vid besiktning visat tecken på osäkra eller defekta tillstånd skall tas ur bruk och kasseras se Kassering 6 3 FÖRVARING TRANSPORT Förvara och transportera SRL blocket i sval torr och ren miljö skyddad från direkt solljus Undvik platser där det kan finnas kemisk...

Страница 29: ...ar karbinkrokar balkkrokar förbindningslänkar mm avseende tecken på skador rost och att de fungerar korrekt I förekommande fall Öppningsmekanismer ska öppna stänga låsa och låsa upp korrekt låsknappar och låstappar ska fungera rätt Vävbandslivlina Figur 20 Kontrollera vävbanden De får inte ha hack A fransar B eller brustna fibrer Leta efter revor avskavningar kraftig nedsmutsning C mögel brännskad...

Страница 30: ...re em contacto com o departamento de atendimento ao cliente da 3M na sua área para obter assistência LIMITAÇÃO DE RESPONSABILIDADE NA MEDIDA DO PERMITIDO PELAS LEIS LOCAIS A 3M NÃO SE RESPONSABILIZA POR QUAISQUER DANOS INDIRETOS INCIDENTAIS ESPECIAIS OU CONSEQUENTES INCLUINDO MAS NÃO SE LIMITANDO À PERDA DE LUCROS DE ALGUMA FORMA RELACIONADA COM OS PRODUTOS INDEPENDENTEMENTE DA BASE LEGAL INVOCADA...

Страница 31: ...AAN LUKIEN MUTTA SIIHEN KUITENKAAN RAJOITTUMATTA TUOTTOJEN MENETTÄMINEN MILLÄÄN TAVALLA TUOTTEISIIN LIITTYEN OIKEUSTEORIASTA HUOLIMATTA ÜLEMAAILMNE TOOTEGARANTII PIIRATUD HEASTAMISVAHENDID JA PIIRATUD VASTUTUS GARANTII JÄRGMINE ESITATAKSE IGASUGUSTE OTSESTE VÕI KAUDSETE GARANTIIDE VÕI TINGIMUSTE ASEMEL SEALHULGAS KAUDSETE GARANTIIDE VÕI TINGIMUSTE ASEMEL MÜÜDAVUSE SUHTES VÕI SOBIVUSE SUHTES TEATAV...

Страница 32: ...zervă dreptul de a solicita ca produsul să fie returnat la unitatea sa în vederea evaluării cererii de aplicare a garanției Această garanție nu acoperă deteriorarea produselor cauzată de uzură de utilizare abuzivă sau inadecvată de avarierea în tranzit de faptul că produsul nu a fost supus operațiunilor de mentenanță sau alte deteriorări ce ies din sfera de control a 3M 3M va fi singurul care va apr...

Страница 33: ...m WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC GLOBAL PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Unless otherwise provided by lo...

Отзывы: