background image

12

3.0 INSTALLATION

 

;

Installation of the DBI-SALA Perimeter Limiter must be supervised by a Qualified Person

1

. The installation must be 

certified by a Competent Person

2

 as meeting the criteria for a Certified Anchorage, or that it is capable of supporting 

the potential forces that could be encountered during a fall.

1

2

3.1 PLANNING:

 Plan your fall protection system prior to installation of the Perimter Limiter. Account for all factors that may 

affect your safety before, during and after a fall. Consider all requirements, limitations, and specifications defined in 

Section 2 and Table 1.

3.2 

INSTALLING THE PERIMETER LIMITER:

 The Perimeter Limiter is shipped with the Mast Arm installed backwards and 

with a smaller Mast for shipping purposes only. To install the Perimeter Limiter:

1.  Remove the Mast Arm from the temporary shipping Mast.
2.  Remove and discard the shipping Mast.

3.  Install the Mast that was shipped loose and install the Mast Arm on the new Mast in the correct orientation shown in 

Figure 1.

4.  Replace all pins before use.

5.  Use the positioning handles on the rear of the weight cart and positioning bars on the front of the unit to position the 

unit at the desired work location.

6.  Once the unit is in proper position and alignment, raise the front and rear tire jacks until the foot pads reach the work 

surface. Continue to rotate the jack handles until all three wheels are lifted off the work surface and rotate freely to 

ensure the weight of the unit is transferred to the foot pads.

7.  Attach your personal fall arrest system (PFAS) to the attachments points on the mast arm (see Figure 1). Refer to the 

PFAS manufacturer’s instructions for correct attachment and use of the PFAS. Do not attach more than one PFAS to 

an attachment point. Do not attach more than two PFAS to the Perimeter Limiter.

 

;

Do not use the system with the temporary shipping Mast installed. Remove, replace, and discard the 

temporary Mast before use.

4.0 USE

4.1 

BEFORE EACH USE:

 Verify that your work area and Personal Fall Arrest System (PFAS) meet all criteria defined in 

Section 2 and a formal Rescue Plan is in place. Inspect the Perimeter Limiter per the ‘

User

’ inspection points defined on 

the “

Inspection and Maintenance Log

” (Table 2). If inspection reveals an unsafe or defective condition, do not use the 

system. Remove the system from service and destroy, or contact 3M regarding replacement or repair.

4.2 

FALL ARREST CONNECTIONS:

 The Perimeter Limiter is used with a Full Body Harness and Energy Absorbing Lanyard or 

Self-Retracting Device (SRD).

4.3   LOCATION:

 See Figure 9. The Perimeter Limiter must be located a sufficent distance from the edge of a working surface. 

Minimum distance allowed is 2 ft. (0.6 m) from the front (A) of the unit and 3 ft. (0.9 m) from the side (B) of the unit. 

4.4 

SAFE WORK ZONE:

 See Figure 10. A: User 1 safe working zone, B: User 2 safe working zone, C: 26’ maximum, D: 24’ 

maximum work zone. Always work within the safe work zone of the Perimeter Limiter to avoid rocking or tipping the unit.

• Do not work above the surface level.
• Avoid working where the line may cross or tangle within another object or worker.
• Avoid slack line.
• Use shackles located on the gusset at the mast base and on the top center of the weight cart for lifting the unit to the 

work area. Always use both shackles when lifting unit.

5.0 INSPECTION

5.1 

INSPECTION FREQUENCY:

 The Perimter Limiter must be inspected at the intervals defined in Section 1. Inspection 

procedures are described in the 

“Inspection and Maintenance Log” (Table 2)

. Inspect all other components of the Fall 

Protection System per the frequencies and procedures defined in the manufacturer’s instructions.

 

;

Perimeter Limiters are equipped with a Radio Frequency Identification (RFID) Tag. The RFID Tag can be used in 

conjunction with a Handheld Reading Device to simplify inspection and inventory control and provide records for your 

fall protection equipment.

5.2 DEFECTS:

 If inspection reveals an unsafe or defective condition, remove the Perimeter Limiter from service immediately 

and contact 3M regarding replacement or repair. Do not attempt to repair the Fall Arrest System.

 

;

Authorized Repairs Only: 

Only 3M or parties authorized in writing my make repairs to this equipment.

Содержание DBI SALA 2100090

Страница 1: ... 3M 2020 USER INSTRUCTIONS 5902381 Rev D PERIMETER LIMITER Counterweight Fall Arrest System 1 2100090 OSHA 1926 502 OSHA 1910 140 ...

Страница 2: ......

Страница 3: ...3 2 C A B D G F E H I 3 4 C B A FC B C FC ...

Страница 4: ...4 5 6 A B C A B C D E F G 7 8 45 45 45 ...

Страница 5: ...5 9 A B C D 10 A B D C ...

Страница 6: ...6 11 B D A F E ...

Страница 7: ...20XX 20__ 20__ 20__ 20__ 20__ 20__ 20__ 20__ 20__ XX XX ABC 20__ C E B 8525185 Rev D 310 lbs 140 kg 310 lbs 140 kg 1 350 lb 6 kN MAF 900 lb 4 kN AAF OSHA 1926 502 1910 140 2 0 61m 24 7 31m 3 0 91m 26 7 92m D F ...

Страница 8: ...ems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent or Qualified Person before using these systems TIE OFF ADAPTERS Ensure the tie off adapter device is tight against the anchoring structure Never leave sla...

Страница 9: ...yards etc used with the Perimeter Limiter must limit Arresting Force to the following values as determined by the applicable standard Applicable Standards Maximum Arresting Force Average Arresting Force OSHA 1 350 lbf 6 0 kN 900 lbf 4 0 kN Dimensions See Figure 7 Product Weight 2 015 lb 914 kg Standards Meets the test requirements of OSHA 1926 502 and 1910 140 Component Specifications Figure 2 Ref...

Страница 10: ...es or overhead materials that may fall and contact the user or Personal Fall Arrest System 2 5 FALL CLEARANCE Figure 4 illustrates the components of a Fall Arrest There must be sufficient Fall Clearance FC to arrest a fall before the user strikes the ground or other obstruction Clearance is affected by a number of factors including Anchorage Location A Lanyard Length B Lanyard Deceleration Distanc...

Страница 11: ...unless the snap hook complies is equipped with a 3 600 lb 16 kN gate Check the marking on your snap hook to verify that it is appropriate for your application C In a false engagement where features that protrude from the snap hook or carabiner catch on the anchor and without visual confirmation seems to be fully engaged to the anchor point D To each other E Directly to webbing or rope lanyard or t...

Страница 12: ...Fall Arrest System PFAS meet all criteria defined in Section 2 and a formal Rescue Plan is in place Inspect the Perimeter Limiter per the User inspection points defined on the Inspection and Maintenance Log Table 2 If inspection reveals an unsafe or defective condition do not use the system Remove the system from service and destroy or contact 3M regarding replacement or repair 4 2 FALL ARREST CON...

Страница 13: ...fective conditions remove the system from service and contact 3M regarding replacement or repair 6 3 STORAGE AND TRANSPORT When not in use store and transport the Fixed Beam Anchor and associated fall protection equipment in a cool dry clean environment out of direct sunlight Avoid areas where chemical vapors may exist Thoroughly inspect components after extended storage 7 0 LABELS Figure 11 illus...

Страница 14: ...orrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date...

Страница 15: ......

Страница 16: ...m WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC GLOBAL PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Unless otherwise provided by lo...

Отзывы: