3M DBI SALA 2100090 Скачать руководство пользователя страница 8

FORM NO: 5908299  REV: A

8

SAFETY INFORMATION

Please read, understand, and follow all safety information contained in these instructions prior to the use of this Anchorage Connector. 

FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH.

These instructions must be provided to the user of this equipment. Retain these instructions for future reference.

Intended Use:

This Anchorage Connector is intended for use as part of a complete personal fall protection system.

Use in any other application including, but not limited to, material handling, recreational or sports related activities, or other activities not described in 

the User Instructions, is not approved by 3M and could result in serious injury or death.

This device is only to be used by trained users in workplace applications.

 

!

WARNING

This Anchorage Connector is part of a personal fall protection system. It is expected that all users be fully trained in the safe installation and operation 

of their personal fall protection system. 

Misuse of this device could result in serious injury or death.

 For proper selection, operation, installation, 

maintenance, and service, refer to these User Instructions and all manufacturer recommendations, see your supervisor, or contact 3M Technical Service.

• 

To reduce the risks associated with working with an Anchorage Connector which, if not avoided, could result in serious injury or 

death:

 

-

Inspect the device before each use, at least annually, and after any fall event. Inspect in accordance with the User Instructions.

 

-

If inspection reveals an unsafe or defective condition, remove the device from service and repair or replace according to the User Instructions.

 

-

Any device that has been subject to fall arrest or impact force must be immediately removed from service and destroyed.

 

-

The device must only be installed in the specified substrates or on structures detailed in the User Instructions. Installations and use outside the 

scope of this instruction must be approved by 3M Fall Protection.

 

-

The substrate or structure to which the anchorage connector is attached must be able to sustain the static loads specified for the anchor in the 

orientations permitted in the User Instructions.

 

-

Only connect other fall protection subsystems to the designated anchorage connection point on the device.

 

-

Prior to drilling or fastening, ensure no electric lines, gas lines, or other critical embedded systems will be contacted by the drill or the device.

 

-

Ensure that fall protection systems/subsystems assembled from components made by different manufacturers are compatible and meet the 

requirements of applicable standards, including the ANSI Z359 or other applicable fall protection codes, standards, or requirements. Always 

consult a Competent or Qualified Person before using these systems.

 

-

(TIE-OFF ADAPTERS) Ensure the tie-off adapter device is tight against the anchoring structure. Never leave slack in the tie-off adapter device.

• 

To reduce the risks associated with working at height which, if not avoided, could result in serious injury or death:

 

-

Ensure your health and physical condition allow you to safely withstand all of the forces associated with working at height. Consult with your 

doctor if you have any questions regarding your ability to use this equipment.

 

-

Never exceed allowable capacity of your fall protection equipment.

 

-

Never exceed maximum free fall distance of your fall protection equipment.

 

-

Do not use any fall protection equipment that fails pre-use or other scheduled inspections, or if you have concerns about the use or suitability 

of the equipment for your application. Contact 3M Technical Services with any questions.

 

-

Some subsystem and component combinations may interfere with the operation of this equipment. Only use compatible connections. Consult 

3M prior to using this equipment in combination with components or subsystems other than those described in the User Instructions.

 

-

Use extra precautions when working around moving machinery (e.g. top drive of oil rigs) electrical hazards, extreme temperatures, chemical 

hazards, explosive or toxic gases, sharp edges, or below overhead materials that could fall onto you or your fall protection equipment.

 

-

Use Arc Flash or Hot Works devices when working in high heat environments.

 

-

Avoid surfaces and objects that can damage the user or equipment.

 

-

Ensure there is adequate fall clearance when working at height.

 

-

Never modify or alter your fall protection equipment. Only 3M or parties authorized in writing by 3M may make repairs to the equipment.

 

-

Prior to use of fall protection equipment, ensure a rescue plan is in place which allows for prompt rescue if a fall incident occurs.

 

-

If a fall incident occurs, immediately seek medical attention for the worker who has fallen.

 

-

Do not use a body belt for fall arrest applications. Use only a Full Body Harness. 

 

-

Minimize swing falls by working as directly below the anchorage point as possible.

 

-

If training with this device, a secondary fall protection system must be utilized in a manner that does not expose the trainee to an unintended 

fall hazard.

 

-

Always wear appropriate personal protective equipment when installing, using, or inspecting the device/system.

EN

Содержание DBI SALA 2100090

Страница 1: ... 3M 2020 USER INSTRUCTIONS 5902381 Rev D PERIMETER LIMITER Counterweight Fall Arrest System 1 2100090 OSHA 1926 502 OSHA 1910 140 ...

Страница 2: ......

Страница 3: ...3 2 C A B D G F E H I 3 4 C B A FC B C FC ...

Страница 4: ...4 5 6 A B C A B C D E F G 7 8 45 45 45 ...

Страница 5: ...5 9 A B C D 10 A B D C ...

Страница 6: ...6 11 B D A F E ...

Страница 7: ...20XX 20__ 20__ 20__ 20__ 20__ 20__ 20__ 20__ 20__ XX XX ABC 20__ C E B 8525185 Rev D 310 lbs 140 kg 310 lbs 140 kg 1 350 lb 6 kN MAF 900 lb 4 kN AAF OSHA 1926 502 1910 140 2 0 61m 24 7 31m 3 0 91m 26 7 92m D F ...

Страница 8: ...ems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent or Qualified Person before using these systems TIE OFF ADAPTERS Ensure the tie off adapter device is tight against the anchoring structure Never leave sla...

Страница 9: ...yards etc used with the Perimeter Limiter must limit Arresting Force to the following values as determined by the applicable standard Applicable Standards Maximum Arresting Force Average Arresting Force OSHA 1 350 lbf 6 0 kN 900 lbf 4 0 kN Dimensions See Figure 7 Product Weight 2 015 lb 914 kg Standards Meets the test requirements of OSHA 1926 502 and 1910 140 Component Specifications Figure 2 Ref...

Страница 10: ...es or overhead materials that may fall and contact the user or Personal Fall Arrest System 2 5 FALL CLEARANCE Figure 4 illustrates the components of a Fall Arrest There must be sufficient Fall Clearance FC to arrest a fall before the user strikes the ground or other obstruction Clearance is affected by a number of factors including Anchorage Location A Lanyard Length B Lanyard Deceleration Distanc...

Страница 11: ...unless the snap hook complies is equipped with a 3 600 lb 16 kN gate Check the marking on your snap hook to verify that it is appropriate for your application C In a false engagement where features that protrude from the snap hook or carabiner catch on the anchor and without visual confirmation seems to be fully engaged to the anchor point D To each other E Directly to webbing or rope lanyard or t...

Страница 12: ...Fall Arrest System PFAS meet all criteria defined in Section 2 and a formal Rescue Plan is in place Inspect the Perimeter Limiter per the User inspection points defined on the Inspection and Maintenance Log Table 2 If inspection reveals an unsafe or defective condition do not use the system Remove the system from service and destroy or contact 3M regarding replacement or repair 4 2 FALL ARREST CON...

Страница 13: ...fective conditions remove the system from service and contact 3M regarding replacement or repair 6 3 STORAGE AND TRANSPORT When not in use store and transport the Fixed Beam Anchor and associated fall protection equipment in a cool dry clean environment out of direct sunlight Avoid areas where chemical vapors may exist Thoroughly inspect components after extended storage 7 0 LABELS Figure 11 illus...

Страница 14: ...orrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date...

Страница 15: ......

Страница 16: ...m WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC GLOBAL PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Unless otherwise provided by lo...