10
1.0 PRODUCT APPLICATION
1.1 PURPOSE:
Anchorage Connectors are designed to provide anchorage connection points for Fall Arrest
1
, Fall Restraint
2
,
Work Positioning
3
, or Rescue
4
systems.
;
Fall Protection Only:
This Anchorage Connector is for connection of Fall Protection Equipment. Do not connect
Lifting Equipment to the Anchorage Connector.
1.2
STANDARDS:
Your Anchorage Connector conforms to the national or regional standard(s) identified on the front cover
of these instructions. If this product is resold outside the original country of destination, the re-seller must provide these
instructions in the language of the country in which the product will be used.
1.3 SUPERVISION:
Use of this equipment must be supervised by a Competent Person
5
.
1.4 TRAINING:
This equipment must be installed and used by persons trained in its correct application. This manual is to
be used as part of an employee training program as required by ANSI and OSHA, and/or regional regulations. It is the
responsibility of the users and installers of this equipment to ensure they are familiar with these instructions, trained in
the correct care and use of this equipment, and are aware of the operating characteristics, application limitations, and
consequences of improper use of this equipment.
1.5
RESCUE PLAN:
When using this equipment and connecting subsystem(s), the employer must have a rescue plan and
the means at hand to implement and communicate that plan to users, authorized persons
6
, and rescuers
7
. A trained, on-
site rescue team is recommended. Team members should be provided with the equipment and techniques to perform a
successful rescue. Training should be provided on a periodic basis to ensure rescuer proficiency.
2.0 SYSTEM REQUIREMENTS
2.1 ANCHORAGE:
Anchorage requirements vary with the fall protection application. Structure on which the
Anchorage Connector is placed or mounted must meet the Anchorage specifications defined in Table 1.
2.2
PERSONAL FALL ARREST SYSTEM:
Figure 1 illustrates the application of this Anchorage Connector. Personal Fall Arrest
Systems (PFAS) used with the system must meet applicable Fall Protection standards, codes, and requirements. The PFAS
must incorporate a Full Body Harness and limit Arresting Force to the values defined in Table 1.
2.3
FALL PATH AND SRD LOCKING SPEED:
A clear path is required to assure positive locking of an SRD. Situations which
do not allow for an unobstructed fall path should be avoided. Working in confined or cramped spaces may not allow the
body to reach sufficient speed to cause the SRD to lock if a fall occurs. Working on slowly shifting material, such as sand
or grain, may not allow enough speed buildup to cause the SRD to lock.
2.4 HAZARDS:
Use of this equipment in areas with environmental hazards may require additional precautions to prevent
injury to the user or damage to the equipment. Hazards may include, but are not limited to: heat, chemicals, corrosive
environments, high voltage power lines, explosive or toxic gases, moving machinery, sharp edges, or overhead materials
that may fall and contact the user or Personal Fall Arrest System.
2.5
FALL CLEARANCE:
Figure 4 illustrates the components of a Fall Arrest. There must be sufficient Fall Clearance (FC)
to arrest a fall before the user strikes the ground or other obstruction. Clearance is affected by a number of factors
including: Anchorage Location, (A) Lanyard Length, (B) Lanyard Deceleration Distance or SRD Maximum Arrest Distance,
(C) Harness Stretch and D-Ring/Connector Length and Settling. Refer to the instructions included with your Fall Arrest
subsystem for specifics regarding Fall Clearance calculation.
2.6
SWING FALLS:
Swing Falls occur when the anchorage point is not directly above the point where a fall occurs (see Figure
5). The force of striking an object in a swing fall may cause serious injury or death. Minimize swing falls by working as directly
below the anchorage point as possible. Do not permit a swing fall if injury could occur. Swing falls will significantly increase the
clearance required when a Self-Retracting Device or other variable length connecting subsystem is used.
2.7
COMPONENT COMPATIBILITY:
3M equipment is designed for use with 3M approved components and subsystems
only. Substitutions or replacements made with non-approved components or subsystems may jeopardize compatibility of
equipment and may affect the safety and reliability of the complete system.
2.8
CONNECTOR COMPATIBILITY:
Connectors are considered to be compatible with connecting elements when they
have been designed to work together in such a way that their sizes and shapes do not cause their gate mechanisms to
inadvertently open regardless of how they become oriented. Contact 3M if you have any questions about compatibility.
Connectors (hooks, carabiners, and D-rings) must be capable of supporting at least 5,000 lbs. (22.2 kN). Connectors
must be compatible with the anchorage or other system components. Do not use equipment that is not compatible.
Non-compatible connectors may unintentionally disengage (see Figure 6). Connectors must be compatible in size, shape,
and strength. If the connecting element to which a snap hook or carabiner attaches is undersized or irregular in shape, a
situation could occur where the connecting element applies a force to the gate of the snap hook or carabiner (A). This force
may cause the gate to open (B), allowing the snap hook or carabiner to disengage from the connecting point (C).
Self-locking snap hooks and carabiners are required by ANSI Z359 and OSHA.
2.9
MAKING CONNECTIONS:
Snap hooks and carabiners used with this equipment must be self-locking. Ensure all
connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all
1 Fall Arrest System:
A collection of Fall Protection Equipment configured to arrest a free fall. Protects the user in the event of a fall. Free fall is permitted up to
the limits allowed by the connecting device (either an Energy Absorbing Lanyard or Self-Retracting Device (SRD)).
2 Restraint System:
A collection of Fall Protection Equipment configured to prevent the person’s center of gravity from reaching a fall hazard.Prevents the user
from reaching a hazard. No verical free fall is permitted.