background image

Breathing Resistance

The breathing resistance of the respirator is tested during 

inhalation (continuous flow) and exhalation (cyclical flow). 

The breathing resistance of the respirators shall not exceed 

the following limits:

Maximum Breathing Resistance

EN 149:2001+A1:2009

Classification

Inhalation 

at 30l/min

Inhalation 

at 95l/min

Exhalation 

at 160l/min

FFP1

0.6 mbar

2.1 mbar

3.0 mbar

FFP2

0.7 mbar

2.4 mbar

3.0 mbar

FFP3

1.0 mbar

3.0 mbar

3.0 mbar

Clogging

For single shift use respirators (NR), the clogging test is 

optional. For re-usable respirators (R) this test is mandatory. 

The respirators are loaded with very high amount of Dolomite 

dust which will tend to clog the filter. After loading with the 

required amount of dust, the breathing resistance of the 

respirators shall not exceed the following limits:

Maximum Breathing Resistance

EN 149:2001

+A1:2009

Classification

Inhalation at 95l/min

Inhalation at 160l/

min

FFP1

4.0 mbar  

(valved respirator)

3.0 mbar  

(unvalved respirator)

3.0 mbar  

(valved respirator)

FFP2

5.0 mbar  

(valved respirator)

4.0 mbar  

(unvalved respirator)

3.0 mbar  

(valved respirator)

FFP3

7.0 mbar  

(valved respirator)

5.0 mbar  

(unvalved respirator)

3.0 mbar  

(valved respirator)

Flammability

Tested respirators are mounted on a metallic head which 

rotates with a linear speed of 60mm/s. The respirators are 

passed within 20mm of the tip of an 800

o

C (±50

o

C) propane 

burner flame. The respirator shall not burn or continue to burn 

within 5 seconds of removal from the flame.

Components and Materials

The following materials are used in the production of the 

3M™ Aura™ Particulate Respirators 9300+Series:

Component

Material

Straps

Polyisoprene

Staples

Steel

Nose Foam

Polyurethene

Nose clip

Aluminium

Filter

Polypropylene

Valve

Polypropylene

Exhalation Valve

 Polyisoprene

This product does not contain components made from 

natural rubber latex. 

Product Range

Product

Typical weight

3M ™ Aura™ 

Particulate 

respirator  

9310+

10g

3M ™ Aura™ 

Particulate 

respirator  

9312+

15g

3M ™ Aura™ 

Particulate 

respirator  

9320+ 

9320D+

10g

3M ™ Aura™ 

Particulate 

respirator  

9322+

15g

3M ™ Aura™ 

Particulate 

respirator  

9330+ 

9330D+

10g

3M ™ Aura™ 

Particulate 

respirator  

9332+

15g

Please contact 3M for information about which products are available outside the EU.

3M™ Aura™ Particulate Respirators 9300+ Series

Содержание 9332+ AURA

Страница 1: ...3M SOP NCNDA LOI POF DISCUSSION MSI BUYER PI MSI TO BUYER PAYMENT SHIPMENT...

Страница 2: ...tandards FFP3 Europe EN 149 2001 Comparable to KN99 or N100 Packaging Information 483 263 432mm 12 per box 10 boxes per carton 4 2 kg Refer to the 3M website for more information 3M Aura Particulate R...

Страница 3: ...sts and mists found in a wide variety of industrial applications and other work situations requiring FFP3 protection The 3M Aura Disposable Respirator 9332 provides comfort and style without compromis...

Страница 4: ......

Страница 5: ...ed to hazards Standards Products are classified by filtering efficiency and maximum total inward leakage performance FFP1 FFP2 and FFP3 also by usability and clogging resistance Performance tests in t...

Страница 6: ...irator 4 0 mbar unvalved respirator 3 0 mbar valved respirator FFP3 7 0 mbar valved respirator 5 0 mbar unvalved respirator 3 0 mbar valved respirator Flammability Tested respirators are mounted on a...

Страница 7: ...e and the product thus preventing a good seal Leave the contaminated area immediately if a Breathing becomes difficult b Dizziness or other distress occurs c The respirator becomes damaged d You taste...

Страница 8: ...tors 9300 Series Personal Safety Division 3M United Kingdom PLC 3M Centre Cain Road Bracknell Berkshire RG12 8HT 0870 60 800 60 www 3M co uk safety 3M Ireland Limited The Iveagh Building The Park Carr...

Страница 9: ...the head to eliminate leakage then repeat the fit check If you cannot achieve a proper fit DO NOT enter the hazardous area Consult your supervisor 4 Locate the upper strap across the crown of the hea...

Отзывы: