background image

Storage and Transportation

3M™ Aura™ Particulate Respirators 9300+  Series have a 

shelf life of 5 years from date of manufacture. End of shelf life 

is marked on the product packaging and upon the product. 

Before initial use, always check that the product is within the 

stated shelf life (use by date). 
Product should be stored in clean, dry conditions within 

the temperature range: – 20°C to + 25°C with a maximum 

relative humidity of <80%. When storing or transporting the 

respirator, remove bend in noseclip, align top and bottom 

panels together before pushing the top panel flat. Store 

respirator in original packaging provided.

Warnings and Limitations

Always be sure that the complete product is:

Suitable for the application;

Fitted correctly;

Worn during all periods of exposure;

Replaced when necessary.

Proper selection, training, use and appropriate

maintenance are essential in order for the product to help

protect the wearer from certain airborne contaminants.

Failure to follow all instructions on the use of these

respiratory protection products and/or failure to

properly wear the complete product during all periods

of exposure may adversely affect the wearer’s health,

lead to severe or life threatening illness or permanent

disability.

For suitability and proper use follow local regulations and

refer to all information supplied. For more information

contact a safety professional/3M representative.

Before use, the wearer must be trained in use of the

complete product in accordance with applicable Health

and Safety standards/guidance.

These products do not contain components made from

natural rubber latex.

These product do not protect against gases/vapours

such as glutaraldehyde.

Do not use in atmospheres containing less than 19.5%

oxygen. (3M definition. Individual countries may apply

their own limits on oxygen deficiency. Seek advice if in

doubt).

Do not use for respiratory protection against atmospheric

contaminants/concentrations which are unknown or

immediately dangerous to life and health (IDLH).

Do not use with beards or other facial hair that may

inhibit contact between the face and the product thus

preventing a good seal.

Leave the contaminated area immediately if:

a. Breathing becomes difficult.

b. Dizziness or other distress occurs.

c. The respirator becomes damaged

d. You taste or smell contaminants, or an irritation occurs

Discard and replace the respirator if it becomes

contaminated with blood or other infectious material,

damaged, breathing resistance becomes excessive or at

the end of a shift.

Do not alter, modify, clean or repair this respirator.

In case of intended use in explosive atmospheres,

contact 3M.

Before initial use, always check that the product is within

the stated shelf life.

Fitting Instructions

Before fitting device, ensure hands are clean.  All respirator 

components should be inspected for damage prior to each 

use.
1.

With reverse side up, separate top and bottom panels to

form a cup shape. Bend slighty at centre of the noseclip.

2. Ensure both panels are fully unfolded.
3.

Cup respirator in one hand with open side towards face.

Take both straps in other hand. Hold respirator under

chin, with nosepiece up, and pull straps over head.

4. Locate the upper strap across the crown of the head

and the lower strap below the ears. Straps must not be

twisted. Adjust top and bottom panels for a comfortable

fit, ensuring panels are not folded in.

5.

Using both hands, mould nose clip to the shape of the

lower part of the nose to ensure a close fit and good seal.

Pinching the nose clip using only one hand may result in

less effective respirator performance.

6.

The seal of the respirator on the face should be fit-

checked before entering the workplace.

Seal Check

 

1.

Cover the front of the respirator with both hands being

careful not to disturb the fit of the respirator.

2.

(a) UNVALVED respirator - EXHALE sharply;

(b) VALVED respirator - INHALE sharply;

3.

If air leaks around the nose, re-adjust the nose clip to

eliminate leakage. Repeat the above seal check.

4.

If air leaks at the respirator edges, work the straps back

along the sides of the head to eliminate leakage. Repeat

the above seal check.

If you CANNOT achieve a proper seal  DO NOT enter the 

hazardous area. See your supervisor.

Users should be fit tested in accordance with national 

requirements.

For information regarding fit testing procedures, please 

contact 3M.

3M™ Aura™ Particulate Respirators 9300+ Series

Содержание 9332+ AURA

Страница 1: ...3M SOP NCNDA LOI POF DISCUSSION MSI BUYER PI MSI TO BUYER PAYMENT SHIPMENT...

Страница 2: ...tandards FFP3 Europe EN 149 2001 Comparable to KN99 or N100 Packaging Information 483 263 432mm 12 per box 10 boxes per carton 4 2 kg Refer to the 3M website for more information 3M Aura Particulate R...

Страница 3: ...sts and mists found in a wide variety of industrial applications and other work situations requiring FFP3 protection The 3M Aura Disposable Respirator 9332 provides comfort and style without compromis...

Страница 4: ......

Страница 5: ...ed to hazards Standards Products are classified by filtering efficiency and maximum total inward leakage performance FFP1 FFP2 and FFP3 also by usability and clogging resistance Performance tests in t...

Страница 6: ...irator 4 0 mbar unvalved respirator 3 0 mbar valved respirator FFP3 7 0 mbar valved respirator 5 0 mbar unvalved respirator 3 0 mbar valved respirator Flammability Tested respirators are mounted on a...

Страница 7: ...e and the product thus preventing a good seal Leave the contaminated area immediately if a Breathing becomes difficult b Dizziness or other distress occurs c The respirator becomes damaged d You taste...

Страница 8: ...tors 9300 Series Personal Safety Division 3M United Kingdom PLC 3M Centre Cain Road Bracknell Berkshire RG12 8HT 0870 60 800 60 www 3M co uk safety 3M Ireland Limited The Iveagh Building The Park Carr...

Страница 9: ...the head to eliminate leakage then repeat the fit check If you cannot achieve a proper fit DO NOT enter the hazardous area Consult your supervisor 4 Locate the upper strap across the crown of the hea...

Отзывы: