background image

Fitting Instructions

These fitting instructions must be followed each time a 3M

TM

 Aura

TM

 9300+ Series respirator is worn.

3b.

 Take both straps in your other hand. Hold the respirator 

under your chin, with the nosepiece facing upwards and 

pull the straps over your head.

Upper strap should 

be positioned on the 

crown of the head. 

Strap should not be 

twisted

Make sure the panels

are fully unfolded

Noseclip should be 

moulded around nose 

and cheeks to give a 

good seal

Lower strap should 

be  positioned 

below the ears. 

Strap should not be 

twisted

Respirator should be 

correctly positioned on 

your face and head

Disposable respirators are only effective when there is a good seal between the edges of the respirator and your face. If the seal is poor, 

protection is compromised as contaminated air can leak in through any gaps.

3a. 

Cup the respirator in one hand with the open side towards 

your face. 

1.

 With the reverse side up and using the tab, separate the

top and bottom panels of the respirator to form a cup 

shape. Bend slightly at the centre of the noseclip.

2.

  Ensure that both panels are fully unfolded.

6.

   Perform a fit-check by covering the front of the respirator 

with both hands taking care not to disturb its fit.

 If you’re using an unvalved respirator, 

exhale

 sharply. 

If you’re using a valved respirator, 

inhale

 sharply.

 If air leaks around the nose, readjust the noseclip to eliminate 

leakage then repeat the fit check. If air leaks at the respirator 

edges, work the straps back along the sides of the head to 

eliminate leakage then repeat the fit check. 

If you cannot 

achieve a proper fit, DO NOT enter the hazardous area. 

Consult your supervisor.

4.

   Locate the upper strap across the crown of the head and 

the lower strap below your ears. The straps must not be 

twisted. Adjust the top and bottom panels for a comfortable

fit, ensuring that the panels and tab are not folded in.

5. 

Using both hands, mould the noseclip to the shape of the

nose to ensure a close fit and a good seal.

The respirator may not fit as well if you pinch the 

noseclip using one hand. Use two hands.

+

+

1

2

+

+

+

+

3a

4

5

6

+

3b

+

+

1

2

+

+

+

+

3a

4

5

6

+

3b

+

+

1

2

+

+

+

+

3a

4

5

6

+

3b

+

+

1

2

+

+

+

+

3a

4

5

6

+

3b

+

+

1

2

+

+

+

+

3a

4

5

6

+

3b

+

+

1

2

+

+

+

+

3a

4

5

6

+

3b

Make sure that your face is clean shaven. Respirators should not 

be worn with stubble, beards or other facial hair under the area 

of the face seal as these can prevent a good seal to the face.

Make sure that long hair is tied back and jewellery is removed 

so that it does not interfere with the seal to the face.

+

+

1

2

+

+

+

+

3a

4

5

6

+

3b

The Power to Protect Your World

SM

13898

Please recycle. Printed in UK.

© 3M 2011. All rights reserved

Scan this QR code with your smartphone 

to be directed to further information on 

3M

  Aura

 9300+ Disposable Respirators

For more information visit: www.3M.co.uk/Aura9300plus

3

Safety Solutions 

3M United Kingdom plc

3M Centre

Cain Road

Bracknell

Berkshire RG12 8HT

Tel: 0870 60 800 60

Safety Solutions 3M 

Ireland Limited

 

The Iveagh Building

The Park

Carrickmines

Dublin 18

Tel: 1 800 320 500

3M Safety Solutions – OH&ESD

3M

 Aura

 9300+ Disposable Respirators

Users of 3M Aura 9300+ should be fit tested. Call the 3M Safety Services Coordinator on 

0845 601 3457

 

or visit the website for further information.

CH

AUR

AFP

3M

Содержание 9332+ AURA

Страница 1: ...3M SOP NCNDA LOI POF DISCUSSION MSI BUYER PI MSI TO BUYER PAYMENT SHIPMENT...

Страница 2: ...tandards FFP3 Europe EN 149 2001 Comparable to KN99 or N100 Packaging Information 483 263 432mm 12 per box 10 boxes per carton 4 2 kg Refer to the 3M website for more information 3M Aura Particulate R...

Страница 3: ...sts and mists found in a wide variety of industrial applications and other work situations requiring FFP3 protection The 3M Aura Disposable Respirator 9332 provides comfort and style without compromis...

Страница 4: ......

Страница 5: ...ed to hazards Standards Products are classified by filtering efficiency and maximum total inward leakage performance FFP1 FFP2 and FFP3 also by usability and clogging resistance Performance tests in t...

Страница 6: ...irator 4 0 mbar unvalved respirator 3 0 mbar valved respirator FFP3 7 0 mbar valved respirator 5 0 mbar unvalved respirator 3 0 mbar valved respirator Flammability Tested respirators are mounted on a...

Страница 7: ...e and the product thus preventing a good seal Leave the contaminated area immediately if a Breathing becomes difficult b Dizziness or other distress occurs c The respirator becomes damaged d You taste...

Страница 8: ...tors 9300 Series Personal Safety Division 3M United Kingdom PLC 3M Centre Cain Road Bracknell Berkshire RG12 8HT 0870 60 800 60 www 3M co uk safety 3M Ireland Limited The Iveagh Building The Park Carr...

Страница 9: ...the head to eliminate leakage then repeat the fit check If you cannot achieve a proper fit DO NOT enter the hazardous area Consult your supervisor 4 Locate the upper strap across the crown of the hea...

Отзывы: