Inspection: 
1.     Make sure unit is straight and operates smoothly. 
2.     Make sure the label is affixed to unit. 
3. 

Make sure trigger stop is not bent or damaged. 

4. 

Make sure cables are not kinked, frayed or damaged. 

5. 

Make sure metal components are not damaged. 

6. 

Make sure metal spoons and conical end fitting operate smoothly 
and no metal burrs have occurred. 

7. 

When reusing a previously drilled hole, always inspect the             
hole carefully. 

 
Storage and Cleaning: 
1. 

Blow off unit after each use with compressed air. 

2. 

Store in clean dry environment. 

3. 

Store in secure locked area. 

4. 

Store and put away at the end of each day’s work. 

5. 

Do not pile any objects on top of unit during storage. 

6. 

Keep unit free of grease, oils and dirt. 

7. 

Avoid lending your unit to other workers. 

 
Disposal: 
1.     Dispose of unit after any fall has occurred. 
2.     Dispose of unit if cable becomes kinked or bent. 
3.     Dispose of unit if trigger stop is bent or damaged. 
4.     Dispose of unit if trigger action is rough or sticky. 
5. 

Dispose of unit if return wire becomes bent or frayed. 

6. 

Proper disposal requires the unit’s spoons be cut off the  

 

When installing the SafeClaw, place your thumb inside the anchor loop 
and your first two fingers around the trigger. Retract the trigger until 
the spring bottoms out. With your other hand, pinch the two spoons 
between your thumb and index finger. Hold the trigger fully retracted 
while inserting the unit into bottom of the hole.

 

Company Logo 

Hole Diameter/Size 

Manufactured Date 

Batch Number 
Model Number 

ANSI Z359.1 Mark 

Warning Instructions 

Compliance: 

ANSI Z359.1-07 5,000 lbs. 

OSHA  

1910.66 & 1926.502 

 

Model # 4075 / Batch 000 

Manufactured 00/00/00 

US Patent 6,729,821 
US Patent 7,011,281 
US Patent 7,357,363 

3/4” 

Warning: 

All persons using this 
equipment must read, 

understand and follow all 
instructions. Failure to do 

so may result in serious 

injury or death. 

WARNING DO NOT use in 

wet or uncured concrete. 

Use in normal weight 

concrete with a compression 

strength at least 3,000 PSI 

(20.7 MPa) Use for Fall 

Protection Only 

Patent Markings 



Main Cable 

 

7x19 Aircraft Cable 



End Termination 

304 Stainless Steel 



Spoons 

 

304 Stainless Steel 



Bushing Guide                    304 Stainless Steel 



Stop sleeve 

 

304 Stainless Steel 



Trigger 

 

6061 T-6 Aluminum 



Spring 

 

Zinc Coated Spring Steel 



Swage 

 

Zinc Coated Copper 



Return Wire 

 

1x19 Aircraft Cable 



Plastics   Polyurethane 

If a SafeClaw becomes stuck, insert a punch, screwdriver 
or pointed object into the hole until the tip rests on the 
striker plate Give a LIGHT, blunt tap with a hammer or 
suitable object. The Striker Plate will be easily visible at 
the edge of the hole. 

SafeClaw Anchor inserted 

into a 3” hole 

The metal Stop Sleeve 

must be inserted half 

way into the hole. 

1-800-560-1094 

SafeClaw

 

Reference # 

70071532330 

Содержание 4075

Страница 1: ...d concrete only and may be pulled in all directions up to 90 SafeClaw Fall Protection Anchor can be placed in Horizontal surfaces Vertical surfaces Overhead ceiling surfaces Warning Do not use incompatible connectors with any SafeClaw Anchor Refer to separate instructions supplied with your anchorage connector Spoon End Termination Bushing Guide Stop Sleeve Trigger Spring Swage Anchor Loop Heavy D...

Страница 2: ...must meet the 5 000 lb requirement All personal fall arrest systems must meet all applicable state federal city OSHA and ANSI requirements and any other regulating government body It is the responsibility of the employer to regulate its worker and make sure all laws are being complied with concerning this device This anchorage point attachment must be identified by a qualified or competent person ...

Страница 3: ...eration distances from shock absorbers and make sure you obtain a minimum 2 clearance Swing fall can occur when the worker is not directly under the anchorage point Avoid a swing fall by working directly underneath your anchorage point Swing falls can jeopardize the clearance required with retractable shock absorbing lanyards and other sub systems of your fall protection system Avoid swing fall at...

Страница 4: ... inspect your units prior to use Use the proper method of coupling to anchorage Remove unit from service if a fall has occurred Patch all holes with concrete when job is complete For use by Single User only Pregnant women and minors must not use this product Designed safe working load is 400 LBS 181 kg Do not exceed this weight Important Warnings This product is to be used by trained fall protecti...

Страница 5: ...4 in diameter and drilled at least 3 into the substrate The bored hole walls must be straight and parallel NOTE The bored hole must be of uniform diameter and free of peaks and valleys on the inner wall surfaces Only use quality industrial grade rotary hammers and rotary hammer drill bits NEVER USE A BENT DRILL BIT Drill a straight 3 4 diameter hole at least 3 deep into your substrate utilizing a ...

Страница 6: ... your other hand pinch the two spoons between your thumb and index finger Hold the trigger fully retracted while inserting the unit into bottom of the hole Company Logo Hole Diameter Size Manufactured Date Batch Number Model Number ANSI Z359 1 Mark Warning Instructions Compliance ANSI Z359 1 07 5 000 lbs OSHA 1910 66 1926 502 Model 4075 Batch 000 Manufactured 00 00 00 US Patent 6 729 821 US Patent...

Страница 7: ...ATE OF MANUFACTURE _________________________________________________ MODEL NUMBER _________________________________________________________ 3M Occupational Health Environmental Safety Division 3M Center Building 235 2W 70 Saint Paul MN 55144 1000 USA Technical Assistance 1 800 243 4630 in U S and 1 800 267 4414 in Canada www 3M com FallProtection www 3M com PPESafety ...

Отзывы: