background image

For Technical Support: www.panduit.com/resources/install_maintain.asp

INSTALLATION INSTRUCTIONS

 © Panduit Corp. 2013

PN575B

Page 1 of 4

Specifications

• Cable jacket diameter 0.285 in. max.

• Maximum conductor insulation diameter 0.041 in.

• Panduit recommends T568B wiring scheme for use 

with cable constructed with the brown pair opposing 
the orange pair.

Conductor holes and Contact slots

1

Thread boot and collar onto the cable first.

Remove 2.0" of the outer jacket from the cable end using
wire stripping tool (CJAST). 

Remove matrix foil to expose twisted pairs.

Fan twisted pairs into respective quadrants. The brown
pair should be opposite the orange pair.

When a cable spline (X-shaped filler) is present, cut spline
flush to fanned pairs using wire snipping tool (CWST).

Thread on boot
and collar first!

(Cable ends 1 & 2)

90°

CWST

Strain Relief Boot

Strain Relief Collar

Divider

Load Bar 

Plug Housing

Load Bar

1

8

Divider

Conductor slots and “V” channel

2

Note orientation of the divider depending on cable end 1 
or cable end 2. The “V” channel should be aligned with the 
green pair.

Insert divider posts into the cable. If the cable has an
internal spline, insert divider posts into the brown and
orange quadrants of the spline.

BLU

GRN

“V” channel

BRN

ORG

GRN

BLU

BRN

ORG

(Cable end 2)

(Cable end 1)

“V” channel

3

Arrange conductors to T568B wiring scheme while
minimizing untwist and smooth conductors.

Seat conductors into proper divider slots while holding
divider near the end of the cable jacket.

“V” channel

(Cable end 1)

(Cable end 2)

T568B Wiring Scheme

T568B BRN

8

WHT

7

BRN/

6

GRN WHT

5

BLU/

4

BLU WHT

3

GRN/

2

ORG WHT

1

ORG/

Pin #

“V” channel

Conductor holes

Contact slots

Divider post

Pins

* Denotes packaging quantity.

Category 6A UTP Modular Plug 

for Panduit Patch Cable

T568B & T568A

Part Number: SP6X88P-*