This product is to be used by qualified fall protection personnel only.  It is to be anchored in accordance with manufacturer’s 
requirements in concrete substrate only. Do not anchor in uncured/wet concrete.  
 
The SafeClaw model #4075 is color coded in ORANGE TUBING, and is to be used for FALL PROTECTION ONLY
. This unit 
is not to be used in any other anchoring situation. Concrete must have a compressive strength of at least 3,000 PSI (20.7MPa)

 

 

DO NOT drill anchor hole less then                   

6” from any corner. 

 



If a hole is 6” from an edge or corner the concrete  

        substrate must be 12” thick and 12” wide  
        (example - a 12” x 12” column) 



If a hole is 8” from an edge or corner the concrete  

        substrate must be 10” thick and 16” wide 
        (example - a 10” x 16” column) 



If a hole is 10” from an edge or corner the concrete  

        substrate must be 8” thick and 20” wide  
        (example – a 8” x 20” column) 



If a hole is 12” or more from any corner or edge the  

        concrete substrate must be 5” thick. 

Drilling for Fall Protection 

It is important that you drill your SafeClaw anchor hole to the manufacturer’s required depth 
and hole structure. All holes must be 3/4” in diameter and drilled at least 3” into the substrate.  
The bored hole walls must be straight and parallel. NOTE: The bored hole must be of uniform 
diameter and free of peaks and valleys on the inner wall surfaces. Only use quality industrial 
grade rotary hammers and rotary hammer drill bits.  

 

NEVER USE A BENT DRILL BIT!! 

 

Drill a straight 3/4” diameter hole at least 3” deep into your substrate utilizing a rotary hammer 

drill that uses industrial grade SDS bits. 

 
 

Only use industrial grade rotary hammer drills and drill bits.  

DO NOT USE masonry drill bits 



Drill a 3/4” diameter hole at least 3” deep. 



Blow hole clean with compressed air. 



Drill hole straight into substrate. 



When reusing a previously drilled hole always inspect the hole 
carefully to ensure adequate integrity. 



Insert unit 3 inches deep into hole. 



Set the unit with a slight tug on the anchor loop. 



The 

Stop Sleeve 

must always be partially inserted into the hole. 



Always inspect a previously drilled hole for deformation. Drill 
another proper hole if needed. 



Inspect the unit for damage each time you use it. If damage has 
occurred, dispose of unit. 



Never rely on a unit placed by unqualified workers. 



Remove your unit at the end of each day.  



Never leave a unit inserted in a hole overnight. 



Never drill hole closer than 6” to any edge or corner. 

Содержание 4075

Страница 1: ...d concrete only and may be pulled in all directions up to 90 SafeClaw Fall Protection Anchor can be placed in Horizontal surfaces Vertical surfaces Overhead ceiling surfaces Warning Do not use incompatible connectors with any SafeClaw Anchor Refer to separate instructions supplied with your anchorage connector Spoon End Termination Bushing Guide Stop Sleeve Trigger Spring Swage Anchor Loop Heavy D...

Страница 2: ...must meet the 5 000 lb requirement All personal fall arrest systems must meet all applicable state federal city OSHA and ANSI requirements and any other regulating government body It is the responsibility of the employer to regulate its worker and make sure all laws are being complied with concerning this device This anchorage point attachment must be identified by a qualified or competent person ...

Страница 3: ...eration distances from shock absorbers and make sure you obtain a minimum 2 clearance Swing fall can occur when the worker is not directly under the anchorage point Avoid a swing fall by working directly underneath your anchorage point Swing falls can jeopardize the clearance required with retractable shock absorbing lanyards and other sub systems of your fall protection system Avoid swing fall at...

Страница 4: ... inspect your units prior to use Use the proper method of coupling to anchorage Remove unit from service if a fall has occurred Patch all holes with concrete when job is complete For use by Single User only Pregnant women and minors must not use this product Designed safe working load is 400 LBS 181 kg Do not exceed this weight Important Warnings This product is to be used by trained fall protecti...

Страница 5: ...4 in diameter and drilled at least 3 into the substrate The bored hole walls must be straight and parallel NOTE The bored hole must be of uniform diameter and free of peaks and valleys on the inner wall surfaces Only use quality industrial grade rotary hammers and rotary hammer drill bits NEVER USE A BENT DRILL BIT Drill a straight 3 4 diameter hole at least 3 deep into your substrate utilizing a ...

Страница 6: ... your other hand pinch the two spoons between your thumb and index finger Hold the trigger fully retracted while inserting the unit into bottom of the hole Company Logo Hole Diameter Size Manufactured Date Batch Number Model Number ANSI Z359 1 Mark Warning Instructions Compliance ANSI Z359 1 07 5 000 lbs OSHA 1910 66 1926 502 Model 4075 Batch 000 Manufactured 00 00 00 US Patent 6 729 821 US Patent...

Страница 7: ...ATE OF MANUFACTURE _________________________________________________ MODEL NUMBER _________________________________________________________ 3M Occupational Health Environmental Safety Division 3M Center Building 235 2W 70 Saint Paul MN 55144 1000 USA Technical Assistance 1 800 243 4630 in U S and 1 800 267 4414 in Canada www 3M com FallProtection www 3M com PPESafety ...