background image

GENERAL INSTRUCTIONS AND CARE  

Inspection: 



Make sure unit is straight and operates smoothly. 



Make sure cable is not kinked, frayed or damaged. 



Make sure metal components are not damaged. 



Make sure the Hole Plug slides freely along main cable. 



Make sure the label is affixed to unit and legible. 



When reusing a previously drilled hole, always inspect the hole carefully. 

 

Storage and Cleaning: 



After each use clean with compressed air. 



Store in clean dry environment. 



Store in secure area at the end of each work day. 



Do not pile objects onto or step on the unit. 



Keep unit free of grout, grease, oils and dirt or other contaminates. 



Never lend your unit to other workers. 

 

Disposal: 



Dispose of unit after any fall has occurred. 



Dispose of unit if cable becomes kinked or bent. 



Proper disposal requires the units main cable to be cut.

 



Follow all manufacturer’s instructions. 



Use only compatible connectors. 



Always inspect your units prior to use. 



Use the proper method of coupling to anchorage. 



Remove unit from service if a fall has occurred.  



Patch all holes with concrete when job is complete. 



For use by Single User only. 



Pregnant women and minors must not use this product. 



Designed safe working load is 400 LBS (181 kg). Do not exceed this weight.

 

Important Warnings   

 

This product is to be used by trained fall protection personnel only. It is to be anchored in accordance with  
manufacturer’s requirements.  All persons using this equipment must read and understand all instructions. 
Failure to do so may result in serious injury or death. If a fall occurs, the SafeClaw must be disposed of according 
to the manufacturer instructions. Users should be familiar with regulations governing this equipment. All 
individuals who use this product must be properly trained before using this device.   
 
Use only compatible connectors with any SafeClaw . Refer to separate instructions supplied with your connecting 
device.  
 
Keep unit free of grout, grease, oils, dirt or other contaminates. This could effect the performance of the unit.

 

Содержание 4075

Страница 1: ...d concrete only and may be pulled in all directions up to 90 SafeClaw Fall Protection Anchor can be placed in Horizontal surfaces Vertical surfaces Overhead ceiling surfaces Warning Do not use incompatible connectors with any SafeClaw Anchor Refer to separate instructions supplied with your anchorage connector Spoon End Termination Bushing Guide Stop Sleeve Trigger Spring Swage Anchor Loop Heavy D...

Страница 2: ...must meet the 5 000 lb requirement All personal fall arrest systems must meet all applicable state federal city OSHA and ANSI requirements and any other regulating government body It is the responsibility of the employer to regulate its worker and make sure all laws are being complied with concerning this device This anchorage point attachment must be identified by a qualified or competent person ...

Страница 3: ...eration distances from shock absorbers and make sure you obtain a minimum 2 clearance Swing fall can occur when the worker is not directly under the anchorage point Avoid a swing fall by working directly underneath your anchorage point Swing falls can jeopardize the clearance required with retractable shock absorbing lanyards and other sub systems of your fall protection system Avoid swing fall at...

Страница 4: ... inspect your units prior to use Use the proper method of coupling to anchorage Remove unit from service if a fall has occurred Patch all holes with concrete when job is complete For use by Single User only Pregnant women and minors must not use this product Designed safe working load is 400 LBS 181 kg Do not exceed this weight Important Warnings This product is to be used by trained fall protecti...

Страница 5: ...4 in diameter and drilled at least 3 into the substrate The bored hole walls must be straight and parallel NOTE The bored hole must be of uniform diameter and free of peaks and valleys on the inner wall surfaces Only use quality industrial grade rotary hammers and rotary hammer drill bits NEVER USE A BENT DRILL BIT Drill a straight 3 4 diameter hole at least 3 deep into your substrate utilizing a ...

Страница 6: ... your other hand pinch the two spoons between your thumb and index finger Hold the trigger fully retracted while inserting the unit into bottom of the hole Company Logo Hole Diameter Size Manufactured Date Batch Number Model Number ANSI Z359 1 Mark Warning Instructions Compliance ANSI Z359 1 07 5 000 lbs OSHA 1910 66 1926 502 Model 4075 Batch 000 Manufactured 00 00 00 US Patent 6 729 821 US Patent...

Страница 7: ...ATE OF MANUFACTURE _________________________________________________ MODEL NUMBER _________________________________________________________ 3M Occupational Health Environmental Safety Division 3M Center Building 235 2W 70 Saint Paul MN 55144 1000 USA Technical Assistance 1 800 243 4630 in U S and 1 800 267 4414 in Canada www 3M com FallProtection www 3M com PPESafety ...

Отзывы: