18 | 3MWTS Series Water Softeners – Installation Instructions
3MWTS Series Water Softeners – Installation Instructions | 19
Item
3MWTS100
3MWTS150
3MWTS200
Nominal Media Volume, Ft3
1.0
1.5
2.0
Salt Dosage, Lbs.
Salt Efficient Setting
4
6
8
Factory Setting
6
9
12
Maximum Setting
16
16
24
Softening Capacity, grains
At Salt Efficient Setting
16,300
24,200
34,100
At Factory Salt Setting
21,600
32,000
45,000
At Maximum Salt Setting
29,000
43,000
56,800
Salt Efficiency, grains per lb. of salt
At Salt Efficient Setting
4,078
4,026
4,260
Flow Rate At 15 psi Pressure Loss
7.9
11.1
9.6
Pressure Loss, psi At Service Flow
4
5
5
Regeneration Flow Rates, gpm
Backwash
1.7
2.7
2.7
Brine Draw @ 50 psi
0.18
0.26
0.26
Slow Rinse @ 50 psi
0.27
0.34
0.36
Rapid Rinse
1.7
2.7
2.7
Brine Refill
0.5
0.5
0.5
Approximate Water Used (at
Factory Setting)
44
77
78
Regeneration Duration, minutes a (at Factory Setting)
1st Backwash
6
6
6
Brine Draw/Rinse
45
45
45
2nd Backwash
3
3
3
Rapid Rinse
3
3
3
Brine Refill
3’51”
3’51”
7’52”
Approximate Total Time
61
63
65
Inlet/Outlet Size
1” NPT
1”NPT
1” NPT
Media tank Dia. x Ht., in.
8 x 44
10 x 44
10 x 54
Overall D & H w/Valve, in.
Width (Including Brine Tank)
33
35
35
Depth
15
15
15
Height (Including Valve)
53
53
63
Brine Tank, W x D x H, in.
15 x 15 x 34
15 x 15 x 34
15 x 15 x 34
Salt settings below 6# require removal of the salt grid
Salt settings above 24# require optional 18 x 33 brine tank
Brine Tank Capacity
Without Salt Grid Leg Extensions
180
180
180
With Salt Grid Leg Extensions
(required on salt settings above
18 #)
N/A
135
135
Approximate Shipping Wt.
97
125
154
These softeners conform to NSF/ANSI Standard 44 for specific performance claims. When set at the Salt Efficient setting, these softeners meet or exceed
Std. 44 requirement for salt efficiency. Efficiency claim is only valid at the Salt Efficient Setting.
NOTES: For satisfactory performance, indicated flow rates and duration should not be exceeded. Flow rates specified are adequate for normal residential
applications. Do not use Service Flow Rate if treated water is to supply a geothermal heat pump, swimming pool, etc. (contact your Dealer/Installer before
selecting equipment). Service flow rates have been tested against NSF Standard 44.
SECTION 7: SPECIFICATIONS AND OPERATING DATA