12 | 3MWTS Series Water Softeners – Installation Instructions
3MWTS Series Water Softeners – Installation Instructions | 13
User Display Settings
General Operation
When the system is operating, one of two displays will be shown.
Pressing NEXT will alternate between the displays. One of the
displays is always the current time of day. The second display is
one of the following: days remaining or capacity remaining. Days
remaining is the number of days left before the system goes through
a regeneration cycle. Capacity remaining is the number of gallons
that will be treated before the system goes through a regeneration
cycle. The user can scroll between the displays as desired.
If the system has called for a regeneration that will occur at the pre-
set time of regeneration, the words “REGEN TODAY” will appear
on the display. When water is being treated (i.e. water is flowing
through the system) the word “SOFTENING” flashes on the display
if a water meter is installed.
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage.
An example of a time with low water usage is when members of
a household are asleep. If there is a demand for water when the
system is regenerating, untreated water will be used.
When the system begins to regenerate, the display will change to
include information about the step of the regeneration process and
the time remaining for that step to be completed. The system runs
through the steps automatically and will reset itself to help provide
treated water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system sooner
than when the system calls for it, usually referred to as manual
regeneration.
There may be a period of heavy water usage because of guests or a
heavy laundry day.
To initiate a manual regeneration at the present delayed
regeneration time, press and release “REGEN”. The words “REGEN
TODAY” will flash on the display to indicate that the system will
regenerate at the pre-set delayed regeneration time.
NOTE: If you pressed the “REGEN” button in error, pressing the
button again will cancel the request.
To initiate a manual regeneration immediately, press and hold the
“REGEN” button for 3 seconds. The system will begin to regenerate
immediately. The request cannot be cancelled.
NOTE: If brine tank does not contain salt, fi ll with salt and wait at
least two hours before regenerating.
Set Time of Day
The user can also set the time of day. Time should only need to be
set after extended power outages or when daylight saving time
begins or ends. If an extended power outage occurs, the time of day
will fl ash on and off which indicates the time of day should be reset.
Step 1 Press SET CLOCK.
Step 2 Current Time (hour): Set the hour of the day using or
button. AM/PM toggles after 12. Press NEXT to go to Step
3.
Step 3 Current Time (minutes): Set the minutes of the day using
or buttons. Press NEXT to exit Set Clock. Press “REGEN”
to return to previous step.
OR
REGEN TODAY will be
displayed if a regeneration
is expected “Tonight.”
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”
OR
REGEN TODAY will be
displayed if a regeneration
is expected “Tonight.”
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”
OR
REGEN TODAY will be
displayed if a regeneration
is expected “Tonight.”
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”
OR
REGEN TODAY will be
displayed if a regeneration
is expected “Tonight.”
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”
Содержание 3MWTS Series