background image

15

1.0 APPLICATIONS

1.1 PURPOSE:

 3M Self-Retracting Devices (SRDs) are designed to be a component in a personal fall arrest system (PFAS). Figure 1 illustrates 

SRDs covered by this instruction manual and their typical applications. They may be used in most situations where a combination of worker 

mobility and fall protection is required (i.e. inspection work, general construction, maintenance work, oil production, confined space work, 

etc.).

1.2 STANDARDS:

 Your SRD conforms to the national or regional standard(s) identified on the front cover of these instructions. 

1.3 TRAINING:

 This equipment is intended to be used by persons trained in its correct application and use. It is the responsibility of the user to assure 

they are familiar with these instructions and are trained in the correct care and use of this equipment. Users must also be aware of the operating 

characteristics, application limits, and the consequences of improper use.

1.4 LIMITATIONS:

 Always consider the following limitations and requirements when installing or using this equipment:

• 

Capacity: 

This SRD has been compliance tested for use by one person with a combined weight (clothing, tools, etc.) from 130 lbs (59 

kg) to 310 lbs (140 kg).

1

 Make sure all of the components in your system are rated to a capacity appropriate for your application.

• 

Anchorage:

 Anchorages selected for fall arrest systems shall have a strength capable of sustaining static loads applied in the 

directions permitted by the system of at least:

1.  5,000 lbs. (22.2 kN) for non-certified anchorages, or

2.  Two times the maximum arresting force for certified anchorages.
When more than one fall arrest system is attached to an anchorage, the strengths set forth in (1) and (2) above shall 

be multiplied by the number of systems attached to the anchorage.

 

;

From OSHA 1926.500 and 1910.66: Anchorages used for attachment of personal fall arrest systems shall be independent of any 

anchorage being used to support or suspend platforms, and capable of supporting at least 5,000 lbs. per user attached, or be designed, 

installed, and used as part of a complete personal fall arrest systems which maintains a safety factor of at least two, and is under the 

supervision of a qualified person. In Canada, refer to local regulations where applicable.

• 

Locking Speed:

 Situations which do not allow for an unobstructed fall path should be avoided. Working in confined or cramped 

spaces may not allow the body to reach sufficient speed to cause the SRD to lock if a fall occurs. Working on slowly shifting material, 

such as sand or grain,may not allow enough speed buildup to cause the SRD to lock. A clear path is required to assure positive locking 

of the SRD.

• 

Free Fall: 

When used correctly, SRDs will limit the free fall distance to 2 ft. (61 cm). To avoid increased fall distances, do not work above the 

anchorage level. 

Do not lengthen SRDs by connecting a lanyard or similar component without consulting 3M. 

Never clamp, 

knot, or prevent the lifeline from retracting or being taut. Avoid slack line.

• 

Swing Falls:

 Swing Falls occur when the anchorage point is not directly above the point where a fall occurs. The force of striking an 

object in a swing fall may cause serious injury (see Figure 3A). Minimize swing falls by working as directly below the anchorage point 

as possible (Figure 3B). Working away from the anchorage point (Figure 3C) will increase the impact of a swing fall and increase the 

required Fall Clearance (FC).

• 

Fall Clearance:

 Figure 3B illustrates Fall Clearance Calculation. Fall Clearance (FC) is the sum of Free Fall (FF), Deceleration Distance (DD) 

and a Safety Factor (SF): FC = FF +DD + SF. D-Ring Slide and Harness Stretch are included in the Safety Factor. Fall Clearance values have 

been calculated and are charted in Figure 4. A Safety Factor of .45m (1.5 ft) was used for all values in Figure 4.

Figure 4 illustrates Fall Clearance (FC) based on the Horizontal (H) and Vertical (V) distance between the dorsal SRD connection and 

the anchorage point. Each horizontal grid line on the chart(s) represents vertical distance from the anchorage point. Each vertical grid 

line represents horizontal distance from the anchorage point. The Fall Clearance value (FC) is determined by the zone (parabolic lines) 

in which the Horizontal (H) and Vertical (V) grid lines intersect. The example in Figure 4 shows how to determine the required Fall 

Clearance value (FC) for the stated Vertical (V) and Horizontal (H) distances.

 

;

Variable Anchor Points: 

Fall Clearances in Figure 4 are based on a rigid, stationary anchor point. If anchoring to a Horizontal 

Lifeline (HLL) or anchor point that can move, slide, or deform during a fall, the Fall Clearance values from Figure 4 will not 

apply. Refer to the instructions for the HLL or anchor for additional details regarding required fall clearances, deflections, and/or 

deformation.

 

;

Kneeling or Crouching: 

The Clearance Charts in Figure 4 assume the worker is in a standing position, with the SRD anchored 

above the dorsal D-ring. If the worker will be kneeling or crouching, an additional 0.9 m (3 ft) of Fall Clearance is required.

 

;

Never Anchor below the feet:

 Never connect to an anchorage point below your feet.

• 

Hazards: 

Use of this equipment in areas where surrounding hazards exist may require additional precautions to reduce the possibility of injury 

to the user or damage to the equipment. Hazards may include, but are not limited to: high heat, caustic chemicals, corrosive environments, high 

voltage power lines, explosive or toxic gases, moving machinery, or overhead materials that may fall and contact the user or fall arrest system. Avoid 

working where your lifeline may cross or tangle with that of another worker. Avoid working where an object may fall and strike the lifeline; resulting 

in loss of balance or damage to the lifeline. Do not allow the lifeline to pass under arms or between legs. 

• 

Sharp Edges:

 Avoid working where the lifeline will be in contact with or abrade against unprotected sharp edges. Where contact with a 

sharp edge is unavoidable, cover the edge with a protective material.

1 Capacity:

 130 lbs -310 lbs (59 kg- 140 kg) is the capacity range required by standard CSA Z259.2.2-17. Some 3M SRDs are tested to a 420 lbs (191 kg) capacity. See 

Figure 1 for the SRD models covered by this instruction and their capacities.

Содержание 3101257

Страница 1: ...g 420 lb 190 kg 3101222 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101230 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101231 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101232 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101233 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101234 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101243 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101245 1 1 1...

Страница 2: ...310 lb 140 kg 420 lb 190 kg 3101259 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101282 2 1 2 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101283 2 1 2 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101284 2 1 2 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101285 2 1 2 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101286 2 1 2 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101289 2 1 2 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3...

Страница 3: ... 10 11 12 13 14 15 CSA OSHA 3101668 2 1 2 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101671 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101676 1 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101223 2 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101224 2 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 3101249 2 1 1 6 ft 1 8 m 310 lb 140 kg 420 lb 190 kg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ...

Страница 4: ...4 ...

Страница 5: ...5 2 E D C A B G F C A B D H C A B B A C D h 3 A B FC FF DD SF FC FF DD SF C FC H ...

Страница 6: ... 1 5 6 5 ft 2 0 m 5 1 ft 1 6 m 7 1 ft 2 2 m 4 0 ft 1 2 m FC 2 0 6 3 0 9 4 1 2 5 1 5 V H FC x 1 141 191 kg R TM ft m 1 0 3 1 0 3 2 0 6 3 0 9 4 1 2 5 1 5 ft m 1 0 3 2 0 6 3 0 9 4 1 2 5 1 5 7 2 ft 2 2 m 5 7 ft 1 7 m 8 3 ft 2 5 m 4 5 ft 1 4 m FC 2 0 6 3 0 9 4 1 2 5 1 5 V H FC 5 6 A B C A B C D E F G ...

Страница 7: ...7 7 B D C A 8 ...

Страница 8: ...8 9 1 A B B A Delta III ExoFit NEX 2 C C D 3 4 5 A D A ...

Страница 9: ...9 10 1 A B 2 C D D 3 F G E 4 A E 5 F E 6 A D C ...

Страница 10: ...10 11 1 2 3 4 5 6 7 ...

Страница 11: ...11 12 E D A G D B F C F 13 14 A B C 15 ...

Страница 12: ...oir l etiquette RFID pour le numero de serie Patent Pending 9514365 Rev A Model No N De Modele Mfrd Yr Mo Fabr An Mo Lot Length Longueur ft m 3M com FallProtection Red Wing MN 55066 USA See RFID tag for Serial Number Voir l etiquette RFID pour le numero de serie Patent Pending 9514365 Rev A Model No N De Modele Mfrd Yr Mo Fabr An Mo Lot Length Longueur ft m F ...

Страница 13: ... the SRD Avoid sudden or quick movements during normal work operation This may cause the device to lock up Ensure that fall protection systems subsystems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent and ...

Страница 14: ... lb 3 Fixed D Ring SRD Harness Interface Steel 19 mm 3 4 in 16 kN 3600 lb 22 2 kN 5000 lb 4 Cab Mount Stainless Steel 41 mm 1 5 8 in 5 SRD Harness Interface Steel 51 mm 2 in 16 kN 3600 lb 22 2 kN 5000 lb 6 Swivel Eye Steel 22 35 mm 0 88 in inside diameter 22 2 kN 5000 lb 7 Carabiner Aluminum 19 mm 3 4 in 16 kN 3600 lb 22 2 kN 5000 lb 8 Rebar Hook Steel 63 mm 2 1 2 in 16 kN 3600 lb 22 2 kN 5000 lb ...

Страница 15: ...s occur when the anchorage point is not directly above the point where a fall occurs The force of striking an object in a swing fall may cause serious injury see Figure 3A Minimize swing falls by working as directly below the anchorage point as possible Figure 3B Working away from the anchorage point Figure 3C will increase the impact of a swing fall and increase the required Fall Clearance FC Fal...

Страница 16: ... this equipment must be self locking Ensure all connections are compatible in size shape and strength Do not use equipment that is not compatible Ensure all connectors are fully closed and locked 3M connectors snap hooks and carabiners are designed to be used only as specified in each product s user s instructions See Figure 6 for examples of inappropriate connections Do not connect snap hooks and...

Страница 17: ...ivel Eye on the SRD E Thread the Interface through the Swivel Eyes so the SRD hangs from the backbone of the Harness Interface F 4 Position the Harness Interface around the Web Straps Position the open gate of the Harness Interface around the loose Web Straps A 5 Close the Harness Interface Push the Harness Interface Locking Pin D through the loose Web Straps A until it locks in place in the oppos...

Страница 18: ...both layers of harness webbing until you hear a click The pin should be firmly locked in place 4 0 OPERATION First time or infrequent users of Self Retracting Devices SRDs should review the Safety Information at the beginning of this manual prior to use of the SRD 4 1 BEFORE EACH USE Verify that your work area and Personal Fall Arrest System PFAS meet all criteria defined in Section 2 Verify that ...

Страница 19: ...ing a fall must be eliminated 4 8 HORIZONTAL SYSTEMS In applications where the SRD is used in conjunction with a horizontal system i e Horizontal Lifeline Horizontal I Beams Trolley the SRD and horizontal system components must be compatible Horizontal systems must be designed and installed under the supervision of a qualified engineer Consult the horizontal system equipment manufacturer instructi...

Страница 20: ...e If the SRD has been subjected to fall force or inspection reveals an unsafe or defective condition remove the SRD from service and discard see Disposal 6 3 STORAGE TRANSPORT Store and transport the SRD in a cool dry clean environment out of direct sunlight Avoid areas where chemical vapors may exist Thoroughly inspect the SRD after any period of extended storage 6 4 DISPOSAL Dispose of the SRD i...

Страница 21: ...hould open close lock and unlock properly Locking Buttons B and Locking Pins C should function correctly Web Lifeline Figure 18 Inspect webbing material must be free of cuts A frays B or broken fibers Check for tears abrasions heavy soiling C mold burns D or discoloration Inspect stitching Check for pulled or cut stitches Broken stitches may be an indication that the harness has been impact loaded...

Страница 22: ...22 ...

Страница 23: ...struée est nécessaire pour que le dispositif auto rétractable se bloque normalement Évitez les mouvements brusques ou rapides durant le travail normal Ce type de mouvements pourrait provoquer le blocage du dispositif Assurez vous que les systèmes sous systèmes de protection antichute assemblés à partir de composants fabriqués par différents fabricants sont compatibles et répondent aux exigences de...

Страница 24: ... po 16 kN 3 600 lb 22 2 kN 5 000 lb 3 Interface de harnais pour dispositif autorétractable à anneau en D fixe Acier 19 mm 3 4 po 16 kN 3 600 lb 22 2 kN 5 000 lb 4 Montage sur cabine Acier inoxydable 41 mm 1 5 8 po 5 Interface de harnais pour dispositif autorétractable Acier 51 mm 2 po 16 kN 3 600 lb 22 2 kN 5 000 lb 6 Œil pivotant Acier 22 35 mm 0 88 po diamètre intérieur 22 2 kN 5 000 lb 7 Mousqu...

Страница 25: ... la ligne Chutes avec mouvement de balancier Les chutes avec mouvement de balancier surviennent lorsque le point d ancrage n est pas directement au dessus du point où la chute s est produite Si un objet est heurté pendant le mouvement de balancier la force peut être importante et causer des blessures graves voir la Figure 3A Il est possible de réduire les chutes avec mouvement de balancier en trav...

Страница 26: ...u point d attache C 2 7 CONNEXIONS Les crochets à ressort et les mousquetons utilisés avec cet équipement doivent être autoverrouillables S assurer que toutes les connexions sont compatibles en ce qui concerne leur taille leur forme et leur résistance N utiliser aucun équipement non compatible S assurer que tous les connecteurs sont bien fermés et verrouillés Les connecteurs 3M crochets à ressort ...

Страница 27: ...pour glisser l interface de harnais pour dispositif autorétractable entre les sangles en toile et le rembourrage de protection de l anneau en D 2 Ouvrir l interface du harnais Pousser simultanément les boutons d arrêt C et faire glisser la goupille d arrêt D vers l extérieur 3 Positionner le dispositif autorétractable sur l interface du harnais Insérer la clavette ouverte sur l interface du harnai...

Страница 28: ... position verrouillée Une fois que l interface du harnais est fermée tirer les sangles en toile A à travers l anneau en D dorsal pour éliminer le mou au niveau des sangles et fixer fermement l interface du harnais entre les sangles en toile et le rembourrage de protection dorsal Mousqueton à goupille double DBI SALA 3MMC Cette fixation de harnais peut être utilisée pour fixer une ou deux lignes de...

Страница 29: ...l peut compromettre la compatibilité du raccordement en raison de l interaction entre les connecteurs Cela est donc déconseillé Le raccordement de chaque longe du dispositif autorétractable à des points d ancrage distincts est acceptable figure 14B Chaque point de raccordement doit indépendamment soutenir 10 kN 2 248 lb ou être un système technique comme c est le cas d une ligne de vie horizontale...

Страница 30: ... satisfait aux critères d inspection il peut être utilisé 6 0 ENTRETIEN et ENTREPOSAGE 6 1 NETTOYAGE Les procédures de nettoyage du dispositif autorétractable sont les suivantes Nettoyer régulièrement l extérieur du dispositif autorétractable avec une solution d eau et de savon doux Positionner le dispositif autorétractable de manière à faire écouler le surplus d eau Nettoyer les étiquettes au bes...

Страница 31: ... état de fonctionnement Lorsque présents Les clavettes A devraient s ouvrir se fermer se verrouiller et se déverrouiller correctement et les boutons d arrêt B et les goupilles d arrêt C devraient fonctionner correctement Ligne de vie en toile Figure 18 Inspecter les sangles elles doivent être exemptes de coupures A d effilochage B ou de fibres cassées Inspecter le matériel pour déceler toutes déch...

Страница 32: ... the right to require product be returned to its facility for evaluation of warranty claims This warranty does not cover product damage due to wear abuse misuse damage in transit failure to maintain the product or other damage beyond 3M s control 3M will be the sole judge of product condition and warranty options This warranty applies only to the original purchaser and is the only warranty applica...