background image

Pag. 23 

DUALNET—6 INSTRUCTION MANUAL 

ENGLISH 

 

NOTE:  If the end user wishes to know 
which sensor has triggered the alarm, 
low battery or tamper, it is best to 
memorize only 1 sensor in each zone.

 

Group 

0-1-2-3 = this means that each zone 
may memorize up to 4 sensor codes 
and the number 0 to 3 will indicate the 
order in which they have been  
Learned in each zone.

 

 

   ActivateSensor  

    Delete  Sensor

 

On the display appears: 
   
 
 
 
 

To memorize           To cancel 
 

 

 

With keys            or            select  “

Activate sensor

” to learn the Peg-3 “Pegaso” code. 

 

If the panel does not learn the 
code, the display will show “Failure” press the key          and repeat 
the above procedure once again. 

 

If the Peg-3 code has been previously memorized, on the display will 
appear “Update ?”  By pressing         the Peg-3 transmitter code will 
moved to a new position and memorized.  

NOTE: 

If the password is in the same position, it may be cancelled.  If 

this takes place it must be again memorized.  
Press once again           if  you wish to memorize additional Peg-3 
transmitters otherwise press           to return to the main menu.

 

 

   ActivateSensor 

    Learning 

With the Peg-3 keychain transmit-
ter press the Arm button and 
send transmission with-in 20 
seconds. See page 27.

 

 

   

    Success

 

E

 

   ActivateSensor 

    Failure

 

 

   00SensorExists 

    Update?

 

E

E

#

If you desire to cancel a Peg-3 transmitter already memorized, 
press the keys          or             until the Display shows: “Delete 
sensor”.  Then press          to confirm. 

 

Press           to proceed.

 

E

12. PROGRAMMING THE WIRELESS SENSORS 

 

Enter the programming main menu and go to the window 

“Programming sensors” 

 
 
 
 
 
Press the key  
On the display will appear:  
 
 
 
 

 

 
To select the zone number you must press the key            2 times and then select a zone from  
15 to 44.  These are the 30 wireless zones available.  On the display will appear:  

 
 
 
 
 
 

 

Every zone can memorize 4 different sensors codes. The group number indicates the sequence of   
memorization. Press          to cancel the previous number select a new number and confirm. 

E

E

The zone 00 is associated to 
the Peg-3.  So the zone 00 
must not be used for the 
wireless sensors.  Use only 
the zones from 15 to 44.

 

 

    ActivateSensor  

     Delete sensor.

 

 

   Deleting  Sensor 

    Success

 

E

Pr 

 

  

 

Set  Smart  Zone 

                      

 

  

     

ogram  Sensor 

 

  Zone  Number 

                               00

 

 

  Group  Number 

                                  0

 

Содержание Dualnet-6

Страница 1: ...ia del Melograno N 13 00040 Ariccia Roma Italy Tel 39 06 97249118 Fax 39 06 45557618 e mail m tomasino treisystems com Website www treisystems com Dualnet 6 Combined Hardwired and Wireless Control Alarm Panel with Incorporated Telephone diallers GSM PSTN Digital 2014 03 10 10 30AM MON ...

Страница 2: ... Message 14 04 How to set the entrance delay time 15 05 How to set the exit delay time 15 06 Setting the siren trigger time 16 07 Management of Central Monitoring Station SMS 17 08 Telephone line Tamper control 18 09 Zone Settings 19 Indication of how to define a zone 20 10 Settings of the Smart Zones 21 11 Programming the Peg 3 keychain transmitter 22 12 Programming the wireless sensors 23 13 Ala...

Страница 3: ... between the control panel wireless sensors and the wireless sirens The DUALNET 6 is compatible with the DVR 6 a combined wireless PIR sensor and digital vedio recording product DVR which acts as a normal wireless PIR sensor and at the same time can make an Audio Visual recording of the protected area on incorporated SD card with memorized time and date General Characteristics Split type with main...

Страница 4: ...rmally open alarm relay When panel is in stand by this relay is Normally Open When panel is trig gered a negative command will be present Maximum drain 2Amp 17 Output for electronic siren This output must be connect to a common ground No voltage present when panel is in stand by When the panel is triggered to 13 8 Vdc will be present for the alarm duration time Maximum drain 2 amp 18 This output m...

Страница 5: ...he PSTN telephone line to the control panel Be sure that this line is direct and not through a PBX system If connected after the ASDL station use an appropriate line filter Attention For the connection of terminals 22 to 28 with the touch screen keypad DN 6KP it is necessary to use an adequately shielded and ground cable Type normally used in alarm installations 2 x 0 50 mm Double balanced line co...

Страница 6: ... 4 5 6 7 8 9 0 1 2 T E 10 10 2014 12 01 AM MON Return Use a small screw driver to separate these two parts LED INDICATIONS See fig 2 GSM SIGNAL RAPID FLASH NO GSM SIGNAL or NO SIM CARD INSERTED SLOW FLASH GSM SIGNAL NORMAL POWER ON MAINS POWER OK OFF NO MAINS POWER PRESENT FLASHING LOW BATTERY PANEL STATUS ON CONTROL PANEL ARMED IN DAY MODE OFF CONTROL PANEL NOT ARMED FLASHING CONTROL PANEL ARMED ...

Страница 7: ...YYYY zone description Control panel triggered verify zone triggered Communicating 00 YYYY Send message to memorized telephone numbers using SMS or CONTACT ID Armed Disarmed Low battery Battery OK Mains failure 230Vac Mains Okay Manual Test Auto Test System control Send SMS Immediate Send SMS Immediate Send SMS after 5 seconds Send SMS after 5 seconds Send SMS after about 10 minutes Send SMS after ...

Страница 8: ...rigger will take place and transmitted to the CMS by means of Contact ID If this has not been programmed a message will be sent to the memorized tel numbers followed also by a voice messaged if recorded End user password 6 Zone XX By pass Zone XX With control panel armed Once the control panel is disarmed the zone XX will return to its original status End user password 7 Forced Night arming All zo...

Страница 9: ...signal sound for all alarm triggers The wireless sirens have 3 different alarm trigger output sounds Continuous sound for Burglary Bell sound for Fire and Intermittent chirp sound for Emergency Number of Beeps Function Note 1 short beep Every time you press a Keypad button Every time you arm the panel in Day or Night 2 short beeps Every time the control panel is disarmed In case of faulty telephon...

Страница 10: ... with On the display will appear Enter the factory installed Password 1234 and confirm with On the display will appear Digit the new end user password and confirm with On the display will appear Digit the new end user password and confirm with the panel will return to Disarmed status E Note It is necessary that you know the installer password E Insert the new end user Password E E Re Enter Code 99...

Страница 11: ...splay will appear Digit the installer password factory setting is 1234 and confirm with On the display will appear Digit the new Password and confirm with On the display will appear Digit the new password and confirm with the control panel will return to Disarmed mode HOW TO CHANGE THE INSTALLER PASSWORD Follow the same above procedure but select the window Master Code 9999 E E E Installer Code En...

Страница 12: ...s command the control panel will return to the armed mode NOTE To avoid a Tamper alarm trigger before exiting the programming mode remove the tamper jumper and connect to plug 1 the S1 female connector of the tamper switch and fix the control panel cover To Confirm and to exit the programming mode To Cancel in case of error To move upward in the menu Previous page To move downward in the menu Next...

Страница 13: ...key if you wish to memo rize other telephone numbers or to return to the main menu Note it is possible to uses this option to send messages of the installation status by SMS to those persons that may take action To memorize the number to call you must press and The key may be used to cancel un wanted telephone numbers Insert the new number and press on the display will appear With the key or selec...

Страница 14: ...ith on the display will appear Record a 10 sec Message by speaking clearly into the microphone Be sure that there is no back ground noise At the end the control panel will automatically exit the programming and enter panel disarmed mode Note To hear and test the voice dialler it is best to use the interrogation mode See paragraph 20 E E Rec Message YES NO Recording Time 10 Re Phone Numbers c Messa...

Страница 15: ...ways 2 figures At the end press the key to return to the previous menu or to go to the next menu 05 HOW TO SET THE EXIT DELAY TIME Enter the menu and go to the window Exit Delay Press the key On the display will appear Set the time form 00 to 59 seconds entering always 2 figures At the end press the key to return to the previous menu or to go to the next E E E E Entry delay 10 Exit delay 10 En Rec...

Страница 16: ... it is possible to set from 00 to 59 minutes Always enter num bers with 2 digits as seen above At the end press the key to return to the previous menu or press to proceed to the next window Set the alarm time for Motion Siren it is possible to set from 00 to 59 minutes Always enter num bers with 2 digits as seen above Note If the siren is sent on 00 no siren will be triggered but all the other ala...

Страница 17: ...appears With the keys or select YES or NO and confirm with key on the display appears With the keys or select YES or NO and confirm with key on the display appears With the keys or select YES or NO and confirm with key In this case the panel will exit the programming mode and activate to send an SMS Manual Test to the 1st Tel number selected like Contact ID to send an SMS that is in the menu Perso...

Страница 18: ...he on board telephone diallers will send in real time all the events taking place 08 TELEPHONE LINE TAMPER CONTROL Enter the programming menu and go to the window PSTN Failure Press the key on the display will appear With the keys or select YES or NO and confirm with Automatically you will return to the preceding menu Note By selecting YES on Phone Anti cut if the control panel is not in programmi...

Страница 19: ...h the next display window see the factory settings on table 1 To select the type of sensor you must press and digit the corresponding number Follow the table 2 and 3 on the following page insert a number between 00 and 15 At the end press key to proceed to the next window With the keys or select if the zone must be bypassed or not and then press the key to proceed to the next window With the keys ...

Страница 20: ...or E113 Water flow alarm 10 Bedroom Window E131 Perimeter alarm window 11 Bedroom PIR E132 Motion detector alarm 12 Livingroom Contact E131 Perimeter alarm window 13 Livingroom Window E131 Perimeter alarm window 14 Livingroom PIR E132 Motion detector alarm 15 Outdoor Sensor E136 Perimeter alarm outdoor PIR Belonging to Zone Bypassed DELAYED Selecting how a zone must function is important You may s...

Страница 21: ...etic contacts MG 1 and MG 8 10 SETTING OF THE SMART ZONES Enter into the main menu and go to the window Set Smart Zone Press the key On the display will appear To select the zone to modify you must press the key and digit a number between 01 and 44 for the zone number you must always use two digits Press the key to confirm Wireless zone 15 16 17 18 19 20 21 22 23 24 Zone type Bypass Delay code 01 ...

Страница 22: ...ll emit a beep Note To use the Door Chime zone it is necessary to activate it with the panel disarmed by entering on the keypad the end user password followed by the number 9 See page 8 At the end press the key to continue and set the next zone or press the key to return to the main menu E E 11 PROGRAMMING THE PEG 3 KEYCHAIN TRANSMITTERS Enter the main menu and go to the window Programming sensors...

Страница 23: ...eg 3 transmitters otherwise press to return to the main menu ActivateSensor Learning With the Peg 3 keychain transmit ter press the Arm button and send transmission with in 20 seconds See page 27 Success E ActivateSensor Failure 00SensorExists Update E E If you desire to cancel a Peg 3 transmitter already memorized press the keys or until the Display shows Delete sensor Then press to confirm Press...

Страница 24: ...el memorizes the code the display will show Memorized if it does not it will show Failure Press the key and repeat the above procedure From a distance of about 5 mt from the keypad and within 20 seconds send a transmission from the sensor E If you desire to cancel a wireless sensor select with the keys or Delete sensor Delete Memorized sensor will appear Press to cancel Press to proceed E E If the...

Страница 25: ...u Set Time 102040 E Time 10 hour 20 minutes 40 seconds A M from 01 00 to 12 00 P M from 12 01 to 24 00 E Set Date 1403101 E Date 14 Year 03 Month 10 Day 1 Day of the week Monday E 14 CONTROL PANEL ACCESS EVENT LOG REPORTS Enter the main menu and go to the window Access Report Press the key On the display will appear With the keys or you may go up and down in the access event log the lowest number ...

Страница 26: ... indicates that the panel has been armed in Day mode To disarm the Dualnet 6 the following SMS message must be sent Example with the factory password 1234 the message to send is 1234CF The Dualnet 6 will reply with an SMS message DISARMED this indicates that the panel has been totally Disarmed REMOTE COMMANDS You must call on of the two Dualnet 6 telephone numbers PSTN or GSM Wait about 20 seconds...

Страница 27: ...e in Day mode and without taking into consideration if a zone is triggered Digit on keypad the following If you wish to ARM the panel in Night mode without any exit delay time and without taking into consideration if a zone is triggered Digit on keypad the following The zones that are triggered when the panel is being armed will be automatically by passed and will become active again if normalized...

Страница 28: ...r If in this installation you have installed a DVR 6 the control panel will also trigger the DVR 6 and a 3 minute audio visual recording will take place in the protected area A triggered control panel may be triggered by Entering the end user password on the KEYPAD Pressing button one on the keychain transmitter PEG 3 2 beeps will be emitted Using a pulse key or electronic key If installed Sending...

Страница 29: ...Also the new battery may be defective 23 Return control panel to factory settings In this section is described how the control panel may be totally reset to the factory values In the programming menu press the digits A long buzzer sound will be heard and the control panel will automatically be returned to its original factory settings The following data will be cancelled All new codes will be canc...

Страница 30: ... DUALNET 6 and enter into programming mode see par 01 page 12 6 With the keys Select the menu Prog Sensors see par 12 page 23 7 To have the panel learn the siren code Select a wireless sensor zone for example zone 44 and position panel in learn mode When the siren sends its code the panel will learn it see par 12 page 23 8 You may now fix the siren to the wall with the screws supplied Re position ...

Страница 31: ...ate Delay Day Night 19 Immediate Delay Day Night 20 Immediate Delay Day Night 21 Immediate Delay Day Night 22 Immediate Delay Day Night 23 Immediate Delay Day Night 24 Immediate Delay Day Night 25 Immediate Delay Day Night 26 Immediate Delay Day Night 27 Immediate Delay Day Night 28 Immediate Delay Day Night 29 Immediate Delay Day Night 30 Immediate Delay Day Night 31 Immediate Delay Day Night 32 ...

Страница 32: ...l m tomasino treisystems com Website http www treisystems com Tre i Systems Installed by Telephone ___________________________ Installation Date TRE i SYSTEMS is not responsible for inappropriate use of this product TRE i SYSTEMS reserves the right to make changes on this product without previous notice In case of problems or faults contact the nearest Tre i Systems service centre ...

Отзывы: