background image

3Com Corporation

 

350 Campus Drive 
Marlborough, MA

 

01752-3064

Copyright © 2008, 3Com Corporation. All rights reserved. No part of this 
documentation may be reproduced in any form or by any means or used to make any 
derivative work (such as translation, transformation, or adaptation) without written 
permission from 3Com Corporation.

3Com Corporation reserves the right to revise this documentation and to make 
changes in content from time to time without obligation on the part of 3Com 
Corporation to provide notification of such revision or change.

3Com Corporation provides this documentation without warranty of any kind, either 
implied or expressed, including, but not limited to, the implied warranties of 
merchantability and fitness for a particular purpose. 3Com may make improvements 
or changes in the product(s) and/or the program(s) described in this documentation 
at any time.

UNITED STATES GOVERNMENT LEGENDS:

If you are a United States government agency, then this documentation and the 
software described herein are provided to you subject to the following: 

United States Government Legend:

 All technical data and computer software is 

commercial in nature and developed solely at private expense. Software is delivered 
as Commercial Computer Software as defined in DFARS 252.227-7014 (June 1995) 
or as a commercial item as defined in FAR 2.101(a) and as such is provided with only 
such rights as are provided in 3Com’s standard commercial license for the Software. 
Technical data is provided with limited rights only as provided in DFAR 252.227-7015 
(Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to 
remove or deface any portion of any legend provided on any licensed program or 
documentation contained in, or delivered to you in conjunction with guide.

Unless otherwise indicated, 3Com registered trademarks are registered in the United 
States and may or may not be registered in other countries.

3Com and the 3Com logo are registered trademarks of 3Com Corporation. VCX is a 
trademark of 3Com Corporation.

Other brand and product names may be registered trademarks or trademarks of their 
respective holders.

Содержание VCX V6000

Страница 1: ...http www 3com com Part Number 900 0513 01 Rev AA Published June 2008 3Com VCX V6000 V6100 VoIP Media Gateway BRI Module Addendum System Release 5 2...

Страница 2: ...ocumentation and the software described herein are provided to you subject to the following United States Government Legend All technical data and computer software is commercial in nature and develop...

Страница 3: ...HE BRI MODULE Features 11 Additional Functions 11 Additional Views 12 CABLING THE V6000 V6100 MEDIA GATEWAYS CONFIGURING THE V6000 V6100 Assigning the IP Address 15 Assigning an IP Address Using HTTP...

Страница 4: ...4...

Страница 5: ...ept responsibility for errors or omissions Updates to this document and other documents can be viewed by registered Technical Support customers at www 3Com com When viewing this manual electronically...

Страница 6: ...electronic and electrical waste must not be disposed of with unsorted waste Please contact your local recycling authority for disposal of this product Abbreviations and Terminology Each abbreviation...

Страница 7: ...rnet FXS Foreign Exchange Station is the interface replacing the Exchange that is the CO or the PBX and connects to analog telephones dial up modems and fax machines The FXS is designed to supply line...

Страница 8: ...8 ABOUT THIS GUIDE...

Страница 9: ...I modules Prior knowledge of IP networks is recommended The following steps provide a quick setup flow 1 Unpack the V6000 V6100 Gateways 2 Mount the V6000 V6100 Gateways 3 Cable the V6000 V6100 Gatewa...

Страница 10: ...10 CHAPTER 1 QUICK START...

Страница 11: ...ed providing a total of up to 20 BRI digital ports Additional Functions The BRI module supports the ITU T I 430 standard which defines the ISDN BRI layer 1 specification The configuration of the BRI p...

Страница 12: ...INFO1 signal on the line the user can STOP the trunk via the board s Web interface or via the SNMP tool Additional Views See Figure 1 for the location and detailed view of the BRI module when it is m...

Страница 13: ...r The connection to the protective grounding must be in accordance with the regulations enforced in the country of installation 2 For BRI interfaces a BRI port can be configured either as TE Terminal...

Страница 14: ...f the Ethernet connectors to a different switch When assigning an IP address to the V6000 V6100 using HTTP see Assigning an IP Address Using HTTP you may need to disconnect this cable and re cable it...

Страница 15: ...nect it to your PC using one of the following two methods Use a standard Ethernet cable to connect the network interface on your PC to a port on a network hub switch Use a second standard Ethernet cab...

Страница 16: ...your PC s IP address and subnet mask to their original settings If necessary restart your PC and re access the V6000 V6100 via the Embedded Web Server with its new assigned IP address Accessing the Em...

Страница 17: ...edded Web Server 17 Figure 4 Enter Network Password Screen 3 Enter the username default Admin and password default Admin Note that the User Name and Password fields are case sensitive 4 Click OK the H...

Страница 18: ...me Page screen shown in Figure 5 and click the Home icon Figure 5 Home Page Numbering System All Modules are numbered consecutively from the left as a Module ID All the digital devices are numbered co...

Страница 19: ...odule ID 2 and the 1st BRI port on the left is Trunk ID 1 as shown in Figure 6 2 In the main menu bar left side click Advanced Configuration the second menu item then select OK PSTN Settings Trunk Set...

Страница 20: ...D 2 Trunk ID 1 in the diagrams 4 From the Protocol Type drop down list green arrow in the above screen select the required protocol in this case BRI EURO ISDN 5 Different trunks can be defined with di...

Страница 21: ...Configuring BRI Trunks 21 Figure 7 Trunk Settings BRI Screen The drop down menu of the above screen extends beyond the size of the display and includes the data shown in Figure 8...

Страница 22: ...ide and vice versa 8 Leave the parameter BRI Layer2 Mode at its default value In this release only P2P is supported 9 To configure the different behavior bits enter the exact hexadecimal bits value in...

Страница 23: ...1 2 to enable both B channels 5 In the adjacent Phone Number field enter the starting phone number these are virtual numbers used only to define enabled B channels 6 In the Trunk Group ID field enter...

Страница 24: ...ce Actions screen appears 2 From the Burn to Flash drop down list select Yes and then click Reset a confirmation message appears when the save is complete Table 4 BRI ini File Parameters ini File Fiel...