Installing the Network Jack
11
Mounting the Network
Jack
After connecting the Network Jack to the network, use the two provided screws
to mount the Network Jack in any standard NEMA-WD6 cubicle opening or wall
outlet.
If the cubicle or wall opening has a depth of fewer than 1.5 inches, does not
support the NEMA-WD6 standard, or does not have pre-drilled screw holes,
mount the Network Jack using the extension ring, as shown below.
Connecting the Local
Power Supply (Optional)
If your network does not support Power Over Ethernet, or if you are not using a
single-port or multi-port Ethernet power supply, you must purchase a local power
CAUTION: Make sure the vents along the edges of the Network Jack faceplate
are clear of any obstructions. If necessary, install the extension ring on recessed
openings to allow airflow to vents.