4-12
C
ONFIGURING
THE
M
ODULE
Trunk Enable
Use the SET TRUNK MODE command to enable or disable
CoreBuilder 5000 Token Ring trunk ports. The command sequence is:
SET TRUNK {slot} ring_in. { 1 or 2} MODE {enable}
ring_out. { 1 or 2}
{disable}
Trunk Network Selection
Use the SET TRUNK NETWORK command to set a trunk port to a
particular backplane or isolated network. The command sequence is:
SET TRUNK {
slot
}
ring_in. {1 or 2} NETWORK {token_ring_1..._10}
ring_out. {1 or 2}
{isolated_1..._11}
Trunk Compatibility Mode
Use the SET TRUNK RING_IN/RING_OUT COMPATIBILITY_MODE
command to ensure that the signalling used by a CoreBuilder 5000
trunk port is compatible with the trunk port connected at the other
end of the copper or fiber cable.
shows the compatibility settings to use when connecting a
CoreBuilder 5000 trunk port:
Table 4-1
CoreBuilder 5000 Compatibility Settings
To Connect CoreBuilder 5000 Modules to:
Set Compatibility Mode to:
CoreBuilder 5000 modules
CoreBuilder 5000
ONline System Concentrator
ONline
ONline 5204M-CR
ONsemble
ONsemble
ONsemble
IBM
®
8250 T04MS-CR
8238
IBM 8238 Token Ring Stackable Hub
8238
IBM 8230 CAU
8230
IBM 8228 MAU
8230
IBM 8250 Multiprotocol Intelligent Hub
8250
IBM 8260 Multiprotocol Intelligent Switching Hub 8260