2N TELEKOMUNIKACE a.s., www.2n.cz
65/97
Connection:
Connect the
to the intercom as follows:
2N
Helios IP Security Relay
®
To the intercom active output (OUT1 or OUT2) , or
To the intercom relay output with a 12 V DC serial external power supply.
Connect the electric lock to the
output as follows:
2N
Helios IP Security Relay
®
To the active 12 V / 700 mA DC output, or
To the relay output with a serial external power supply.
The device also supports a Departure button connected between the ‘PB’ and ‘-
HeliosIP’ terminals. Press the Departure button to activate the output for 5 seconds.
Status signalling:
Green LED
Red LED
Status
blinking
off
Operational mode
on
off
Activated output
blinking
blinking
Programming mode – waiting for initialisation
on
blinking
Error – wrong code received
Configuration:
Connect the
to the properly set intercom switch
2N
Helios IP Security Relay
®
output; refer to the
. Make sure that one LED at least on the
Configuration Manual
is on or blinking.
2N
Helios IP Security Relay
®
Press and hold the
Reset button for 5 seconds to
2N
Helios IP Security Relay
®
put the device in the programming mode (both the red and green LEDs are
blinking).
Содержание Helios IP Vario
Страница 1: ...www 2n cz 2N Helios IP Vario Door Entry IP Intercom Installation Manual Version 2 7 ...
Страница 53: ...2N TELEKOMUNIKACE a s www 2n cz 53 97 ...
Страница 54: ...2N TELEKOMUNIKACE a s www 2n cz 54 97 ...
Страница 60: ...2N TELEKOMUNIKACE a s www 2n cz 60 97 Module settings Refer to the for details Configuration Manual Connection ...
Страница 68: ...2N TELEKOMUNIKACE a s www 2n cz 68 97 Connection ...
Страница 84: ...2N TELEKOMUNIKACE a s www 2n cz 84 97 Incoming call Door opened unlocked ...