background image

 
 

 
 

2N

®

 StarGate / 2N

®

 StarGate UMTS 

2N

® 

BlueStar, 2N

® 

BlueTower 

 

User Manual 

Version 

3.0.0 

Firmware 

2.30.02

 

www.2n.cz

 

 

Содержание BlueStar

Страница 1: ...2N StarGate 2N StarGate UMTS 2N BlueStar 2N BlueTower User Manual Version 3 0 0 Firmware 2 30 02 www 2n cz ...

Страница 2: ... and or trademarks or brands protected by law 2N TELEKOMUNIKACE administers the FAQ database to help you quickly find information and to answer your questions about 2N products and services On faq 2n cz you can find information regarding products adjustment and instructions for optimum use and procedures What to do if Declaration of Conformity 2N TELEKOMUNIKACE a s hereby declares that the 2N Star...

Страница 3: ...d 22 Enhanced CPU Board 25 AUX Board 29 PRI Board 32 VoIP Board 36 GSM UMTS Board 38 2 2 Antenna and Antenna Splitters 44 Antenna Splitter 44 Directional Antenna 46 Discreet Antenna 48 Directional Antenna Connection Cable 48 2 3 Gateway Rack Configuration 50 2 4 Installation 52 Product Completeness Check 52 Installation Conditions 52 VoIP Connection 53 ISDN PRI Connection 54 Licence Limitations 56...

Страница 4: ...sole Access 111 Web Browser Access 113 3 6 2N External Routing Machine Configuration 127 Installation 127 Configuration 129 ERM Control 131 Description of ERM Function 132 ERM Database Structure 132 3 7 2N SIM Star System 135 Product Purpose 135 2N SIM Star Key Components 135 SIM Client Configuration 135 3 8 Voice CallBack Centre Configuration 136 Function Scheme 136 Installation and Licences 137 ...

Страница 5: ...arameters 163 5 2 BlueStar Technical Parameters 165 5 3 BlueTower Technical Parameters 167 6 Supplementary Information 169 6 1 Regulations and Directives 170 6 2 Troubleshooting 171 6 3 List of Abbreviations 173 6 4 General Instructions and Cautions 175 ...

Страница 6: ......

Страница 7: ...ate BlueStar BlueTower product outline its application options and highlight the advantages following from its use This section also includes safety instructions Here is what you can find in this section System Product Description Innovations Terms and Symbols Used ...

Страница 8: ...temperature exceeds 70 C The main power supply unit is located in front of the fan The bottom and upper sides are covered by perforated sheet and the assembly flanges are provided with handrails The system bus is designed as a printed circuit board PCB with DIN connectors and fitted to the inner subrack carrier profiles Front Side Division The subrack width is divided into an 8HP wide mains panel ...

Страница 9: ...wer Supply 2N StarGate with 16 UMTS Boards Enhanced CPU 2 ISDN PRI Interfaces and AC Power Supply Note Please keep all cards in the right positions Wrong positions will cause malfunction of the whole system In the case of VoIP card replacement by ISDN PRI and vice versa please read the instructions in Section 2 Installation ...

Страница 10: ...ateway from the 2N PRI gateway family with the capacity up to 16 GSM UMTS channels The system is integrated in a 19 subrack of the height of 3U and depth of 360mm The front side is open equipped with slots for plug in boards with front panels The panel includes the main switch In case not all GSM UMTS cards are plugged in the vacant section of the front side must be covered with a fixed panel s An...

Страница 11: ...I version Fixed panel with a main switch AC type or power connectors DC type 8HP Basic or enhanced CPU card 4HP AUX card 4HP 1ISDN PRI or 2ISDN PRI card 4HP GSM or UMTS cards one for two GSM UMTS channels Remaining space each 4HP Examples of Used Types 2N BlueStar 8 GSM Boards Basic CPU 2 ISDN PRI Interfaces Integrated Antenna Splitter and AC Power Supply Note Please keep all cards in the right po...

Страница 12: ...g the capacity up to 8 GSM UMTS channels The system is integrated in a small 19 subrack of the height of 3U width of 29HP and depth of 320mm The front side is open equipped with slots for plug in boards with front panels The panel includes the main switch In case not all GSM UMTS cards are plugged in the vacant section of the front side must be covered with a fixed panel s An optional antenna spli...

Страница 13: ...channels Remaining space each 4HP ISDN PRI version Basic or enhanced CPU card 4HP AUX card 4HP 1ISDN PRI or 2ISDN PRI card 4HP GSM or UMTS cards one for two GSM UMTS channels Remaining space each 4HP Examples of Used Types 2N BlueTower with 2 UMTS Boards Enhanced CPU VoIP Interfaces and Integrated ...

Страница 14: ...n Section 2 Installation Power Supply The system uses an industrial power supply unit with natural cooling and an auxiliary external fan which is switched on automatically whenever the power supply temperature exceeds 70 C The power supply unit is designed with a 30 reserve even under the maximum load Power supply types Internal 90 260V 50 60 Hz output 5V 30A Internal 48 DC output 5V 30A The type ...

Страница 15: ...System 1 1 15 High voltage may cause a serious injury or death Tip You are recommended to connect the gateway to the UPS system ...

Страница 16: ... an OS FREE system Two independent 30MHz Philips microprocessors provide an error free operation high speed automatic fault detection and easy upgrade The system also features easy installation simple operation and easy replacement of defective parts as it is composed of plug in boards that communicate independently along system buses As already mentioned the system allows for an easy detection of...

Страница 17: ...allBack Auto CLIP routing DISA dial in Intelligent selection of GSM UMTS module to be used Support of remote SIM card function 2N SIM Star Possibility to replace internal LCR with an external solution 2N ERM Remote control configuration and firmware upgrade High connection rate and ASR low PDD ...

Страница 18: ...reof It is recommended that you use the most recent version of the program to avoid unnecessary problems and shortcomings that have already been eliminated If you program your StarGate BlueStar BlueTower parameters by means of a computer you need the PRI config program or a web browser when using the eCPU web interface Find the latest version of this programming tool at www 2n cz as well At www 2n...

Страница 19: ...this information to prevent damage to the device Caution Important information for system functionality Tip Useful information for quick and efficient functionality Note Routines or advice for efficient use of the device Future Functions A grey marked text in this document specifies the 2N StarGate BlueStar BlueTower functions that will be supported in the future ...

Страница 20: ......

Страница 21: ...nstallation This section describes the 2N StarGate BlueStar BlueTower product and its installation Here is what you can find in this section Plug In Boards Antenna and Antenna Splitters Gateway Rack Configuration Installation ...

Страница 22: ...upports all basic features of the gateway The advanced features of the enhanced version Web interface 2N SIM Star support SMS2Outlook Web configuration and SNMP are not available Board Description The CPU board contains a processor system controlling the whole system The board is designed on a 4 layer PCB of the size of 160x100mm A simple COM1 serial interface an Ethernet connector 10Base T and 5 ...

Страница 23: ... average life is about three years and should be replaced preventively after this time Replacing the lithium battery be sure to turn the subrack power supply unit off using the mains switch and having loosened the two fitting screws push the CPU board out Remove the old battery from the holder using a suitable tool and insert a new one Restore the original status taking the said steps in the oppos...

Страница 24: ...Plug In Boards 2 1 24 Fig 2 1 Configuration Jumpers ...

Страница 25: ... the size of 160x100mm There is also an extension card located on the main PCB The board has one simple COM1 serial interface shared by both the CPUs two Ethernet connectors CPU 10Base T and Ext unit 100Base T and 10 board status LED indicators on the front panel Main Indication LEDs of the main basic CPU Indicates shining that the extension unit is powered on Indicates shining that the extension ...

Страница 26: ...icate with the basic and enhanced CPUs at the same time via a serial interface use COM1 for communication with the enhanced CPU and COM2 located on AUX card for communication with the basic CPU Lithium Battery Replacement Warning An incorrect battery replacement may cause explosion The battery can only be replaced with a battery of the same or equivalent type as recommended by the manufacturer Han...

Страница 27: ...sion board By default jumper JP2 is connected the serial port is switched to the basic CPU JP3 is designed for restoring default settings of the enhanced CPU JP3 is located on the upper PCB To restore the default values follow the steps below Switch off the GSM gateway Remove the CPU card and connect JP3 Insert the CPU card and switch on the GSM gateway Wait for one minute and switch off the GSM g...

Страница 28: ...Plug In Boards 2 1 28 Fig 2 2 Configuration Jumpers JP3 ...

Страница 29: ... voice messages into the AUX board processor memory It provides remote monitoring configuration tracing and firmware upgrade Transmission rate 57 6 kips Bit format start 8bit stop no parity Signals complete 9 pin wiring Board supply indication Shining Switched on Flashing The board is in the sleep mode Board initialisation or error state Shining up to 1 minute Firmware upgrading Continuous shining...

Страница 30: ...ir statuses The JP3 jumper field helps you redirect the COM2 interface for DISA voice message uploading The JP4 jumper block is used for setting the AUX interface to correspond with the handset or headphone configuration By default jumpers JP1 and JP2 are disconnected jumpers Do not change Do not change Connected to Basic CPU Connected to AUX CPU HDLC chip JP4a JP4b JP4c JP4d ...

Страница 31: ...ing remote control over the ISDN PRI interfaces This chipset is an optional part of system The following step by step guide will show you how to plug it into the AUX card Position of the chip cap on the AUX board Insertion of the chip to the cap ATTENTION Please watch the chip orientation it must be the identical with that of the other chips Carefully press the chip into the cap View of a successf...

Страница 32: ...ated by jumpers which provide hardware connection between PRI 1 and PRI 2 in case the system is switched off or inoperative Tip The LED statuses provide basic information on the ISDN interface only For details on the ISDN interface state refer to the configuration tool Board supply indication Shining Switched on Flashing Board in the sleep mode Board initialisation or error state Shining up to 1 m...

Страница 33: ...g of the transmitting and receiving connector pairs the interface configuration must be made using the configuration tool With jumper JP4 you can activate deactivate the back up connection between PRI 1 and PRI 2 in case the system is switched off or the PRI board is not handled by system JP4 Back up connection Activated Deactivated JP4 JP2 PRI 2 interface type settings JP3 PRI 1 interface type se...

Страница 34: ...ce on 2PRI boards And there is no back up connection JP4 either Positions of Tx and Rx Wires Example of Connection with 1ISDN PRI Board 6 Tx 5 Rx 4 Rx 3 Tx 2 nepoužit 1 nepoužit 8 7 6 3 2 1 8 nepoužit 7 nepoužit 5 4 TE mode 1 RX 2 RX 3 not used 4 TX 5 TX 6 not used 7 not used 8 not used NT mode 1 TX 2 TX 3 not used 4 RX 5 RX 6 not used 7 not used 8 not used EuroISDN Q 931 EDSS1 PRI port mode NT Sy...

Страница 35: ...TE or NT and synchronisation type Master Slave must be different on the PBX PSTN and on the gateway The TEI number must have the same value default 0 PRI port mode TE Synchronisation Slave TEI 0 PRI 1 port mode TE Synchronisation Slave TEI 0 PRI 1 port mode TE Synchronisation Slave TEI 0 PRI 1 port mode TE Synchronisation Slave TEI 0 EuroISDN Q 931 EDSS1 EuroISDN Q 931 EDSS1 ...

Страница 36: ... designed as a media gateway It works only with media packets RTP signalling packets SIP must be routed to the basic CPU IP address Tip You have to restart the VoIP card upon any VoIP configuration change Caution For a successful VoIP card initialisation the VoIP board MAC address has to be filled in correctly and the basic CPU must be switched to the VoIP SIP mode and contain the VoIP firmware fi...

Страница 37: ... are no configuration jumpers on the VoIP card Example of Correct VoIP Interface Connection SIP proxy 192 168 1 1 2N StarGate BlueStar BlueTower VoIP card 192 168 1 101 CPU card 192 168 1 100 GSM card s Voice stream RTP packets Signalling SIP packets ...

Страница 38: ...ueTower gateway can use several types of GSM or UMTS boards The board specification includes the type of wireless device s count of SIM cards channel and 2N SIM Star support data Table of available GSM UMTS cards 2009 GSM board with 2 Cinterion MC55i engines 4SIM channel no 2N SIM Star support Board supply indication Shining Switched on Flashing Board in the sleep mode Board initialisation indicat...

Страница 39: ... 8SIM channel no 2N SIM Star support GSM board with 2 Wavecom Q55 WPM100 engines 1SIM channel 2N SIM Star support GSM board with 2 Wavecom Q55 WMP100 engines 4SIM channel 2N SIM Star support UMTS board with 2 SierraWireless MC8790V engines 4SIM channel no 2N SIM Star support UMTS board with 2 SierraWireless MC8790V engines 1SIM channel 2N SIM Star support Note The GSM UMTS boards can be locked for...

Страница 40: ...Plug In Boards 2 1 40 SIM Card Positions on 4SIM Channel Boards Wireless engine Channel 1 Wireless engine Channel 2 Channel 1 Channel 2 ...

Страница 41: ...g In Boards 2 1 41 SIM Card Positions on 8SIM Channel Boards JP2 JP3 JP1 SIM1_4 SIM1_3 SIM1_2 SIM1_1 SIM1_8 SIM1_7 SIM1_6 SIM1_5 SIM2_5 SIM2_6 SIM2_7 SIM2_8 SIM2_1 SIM2_2 SIM2_3 SIM2_4 Channel 1 Channel 1 ...

Страница 42: ...Plug In Boards 2 1 42 SIM Card Positions on 1SIM Channel Boards Wireless engine Channel 1 Wireless engine Channel 1 Channel 1 Channel 2 ...

Страница 43: ...Plug In Boards 2 1 43 SIM Card Positions on 4SIM Channel Boards Wireless engine Channel 1 Wireless engine Channel 1 SIM 1 SIM 3 SIM 2 SIM 4 SIM 1 SIM 3 SIM 2 SIM 4 Channel 1 Channel 2 ...

Страница 44: ...xternal 2N StarGate or internal 2N BlueStar and 2N BlueTower Each splitter consists of one or more passive units each of which has four two inputs and one output Table of standard external antenna splitter configurations Number of inputs Number of outputs Input Output insertion loss Unit high 32 2 15 dB 2U 32 4 11 dB 2U 32 8 8 dB 2U 16 1 15 dB 1U 16 2 11 dB 1U 16 4 8 dB 1U 12 3 8dB 1U Table of int...

Страница 45: ...emale RF parameters Impedance 50 OHM Frequency 850 2100 MHz Insertion loss 8 11 15 dB According to configuration Isolation between two channels 20 dB Output overvoltage protection Device type Gas surge arrester Protected voltage level 90 V Peak current 10 KA Insertion loss 0 2 dB Splitter Examples Internal Antenna Splitter for 2N BlueStar Internal Antenna Splitter for 2N BlueTower ...

Страница 46: ...easurement Directional Antenna The high gain directional YAGI antenna is suitable for outdoor and indoor use Basic parameters of the directional antenna Type CPY 9214 Number of elements 14 Frequency 824 896 1770 2100 MHz Gain 9 5 dB 13 dB Cable RG 58 10m V S W R 1 5 1 Connector N type male dB dB ...

Страница 47: ...Antenna and Antenna Splitters 2 2 47 Directional Antenna An Example of Correct Installation of Directional Antennas ...

Страница 48: ...ll omni directional antenna is designed for indoor use and provides a good GSM UMTS signal quality Basic parameters of the discreet antenna Type Car antenna Gain 2 5dB Cable Coax cable 174A 5 m Connector SMA male Discreet Antenna Directional Antenna Connection Cable 2N offers you a special low attenuation cable in variable lengths The cable terminating connectors are of the N type ...

Страница 49: ...sed connectors N type female Cable size 10 3mm Operating temperature 40 C to 80 C Total weight 120g m Minimum installation temperature 5 C Minimum static bend radius 75mm Attenuation at 860MHz 14 1dB 100m Attenuation at 1000MHz 15 3dB 100m Attenuation at 1750MHz 21 3dB 100m Attenuation at 2050MHz 23 4dB 100m ...

Страница 50: ...d in the gateway hardware rack is pre configured to a defined type of interface VoIP or PRI To change PRI into VoIP or vice versa remember to reconfigure the back bus settings as follows There are six jumpers on the main bus between the 3rd and 4th connector from the right The jumper positions define the gateway type VoIP or PRI There are three setting options 1 ISDN The gateway is configured to w...

Страница 51: ...onfigured to work both with the VoIP and ISDN PRI cards This mode is not supported by the firmware yet and may cause system malfunction Caution Wrong jumper positions may cause malfunction of the whole system Please make changes only if the system is powered off Note The jumper settings are identical for all the gateway types 2N StarGate BlueStar BlueTower ...

Страница 52: ...ith DC power supply Power cable 2 5m 1 1 Mounting set 1 1 Software CD 1 1 Twisted cable for headset 1 1 Headset for test calls 1 1 Serial 9F 9F cable 1 1 Additional packing list items Included device 1PRI card 2PRI card VoIP card Basic CPU card Enhanced CPU card Ethernet cable 3m 1 2 1 Ethernet cable 0 6m 1 2 Note The packing lists are the same for all the gateway types 2N StarGate BlueStar BlueTo...

Страница 53: ...vated by the GSM UMTS provider Warning The outdoor antenna cable has to be connected according to the overvoltage protection and grounding safety rules High temperatures on the installation site may cause short time or permanent gateway errors Warning Do not cover the top bottom and rear sides of the gateway to avoid overheating and gateway error Protection against humidity and extreme temperature...

Страница 54: ...e VoIP SIP mode and contain the VoIP firmware file The integrated Ethernet will not work until the VoIP card has been initialised successfully ISDN PRI Connection The gateway can contain a PRI card with one or two ISDN PRI interfaces depends on the part number PRI 1 is always set as an internal interface PBX connection and PRI 2 as an external interface PSTN connection The Least Cost Routing LCR a...

Страница 55: ...ve PRI interfaces there is a solution as shown below Before using this solution you are recommended to configure your PBX properly or use the DialThru function Red lines are calls to the PSTN orange lines are calls to GSM UMTS networks DialThru Function Installation 1ISDN PRI Card Installation External Synchronisation Option There is an exact time source for synchronisation of the PRI interface li...

Страница 56: ... 2 interface has no influence on signalling and voice calls The PRI board just takes synchronisation pulses from the line Tip For an external synchronisation line you can use a standard cable with an RJ45 connector To disconnect the Rx wires just release the defined jumpers on the PRI 2 interface on the PRI board Licence Limitations Some of the 2N products have time limited software licences e g D...

Страница 57: ...e to both the CPUs Find the latest firmware version plus all software on the enclosed CD or on our website www 2N cz Firmware upgrade for the basic CPU board for eCPU please use the web interface and the dedicated web section Warning To avoid gateway error please use only the firmware files that are designed for your type of gateway and certified by 2N Via a local serial port Connect your PC to th...

Страница 58: ...Upgrade firmware through Ethernet button The configuration tool now automatically uploads the new firmware it takes about 30 seconds After a successful upgrade the gateway will restart automatically Note The remote gateway firmware upgrade is supported only by the CPU with bootware version 2 52 or higher and firmware version 2 30 01 or higher The basic CPU card has to be connected to the Ethernet ...

Страница 59: ...em by setting the GSM basic parameters Call delay parameter in the configuration tool to 2 seconds This parameter extends the delay between the end of one call and the start of another call made via one and the same wireless module Some wireless modules cannot log in to the wireless network even after reset Your GSM UMTS provider may have located the SIM card but refused the login to the wireless ...

Страница 60: ...ooms heavy industrial operations should be avoided The system should be installed horizontally Main Installation Place the gateway into an environment that complies with the gateway working conditions Configure the gateway properly using the configuration software included The gateway mains supply must be backed up and overvoltage protected a line interactive or on line UPS is recommended Any of t...

Страница 61: ...ace An optional part See Subs 2 1 PRI Board for additional information Configuration Ways The system can be configured by any of the following ways Using extended AT commands refer to Subsection Chyba Nenalezen zdroj odkazů Using the configuration tool GUI from a CD Section 3 Using the eCPU web interface An optional part See Subs 2 1 eCPU Board for additional information ...

Страница 62: ......

Страница 63: ...BlueStar BlueTower product Here is what you can find in this section Important Default Settings Quick Step by Step Manual System Upgrade Configuration Tool Enhanced CPU Configuration 2N External Routing Machine Configuration 2N SIM Star System Voice CallBack Centre Configuration ...

Страница 64: ...5 255 255 0 IP address of VoIP board 192 168 1 101 IP mask of VoIP board Same as basic CPU configuration IP address of enhanced CPU By DHCP server IP mask of basic CPU By DHCP server Username Password of basic CPU 2n 2n Username Password of enhanced CPU Admin Username Password of ERM erm ermserver Caution To prevent unauthorised access please change the default access username and password as soon...

Страница 65: ...e PSTN PRI line to PRI 2 on the ISDN PRI card For the PRI board hardware configuration refer to Subs 2 1 PRI Board For examples of a correct connection see Subs 2 4 ISDN PRI Connection 4 Interconnect your PC with the gateway using the attached serial cable Use COM1 located on the gateway CPU card 5 Install and run the configuration tool It is located in the GSM Gateways ISDN PRI section on the enc...

Страница 66: ...calls to the PRI 2 interface All calls from the GSM UMTS network will be rejected All calls from the PRI 2 interface will be rerouted to PRI 1 Should you have a problem with the correct function please read this manual carefully and check all parameters For additional questions refer to the 2N FAQ at http faq 2n cz For a successful installation of the whole system we recommend you to have a traini...

Страница 67: ...ect the basic and enhanced CPUs with the VoIP card Ethernet switch for description of the CPU board see Subs 2 1 Basic CPU Enhanced CPU 13 In the GSM group assignment section assign all the wireless modules to the incoming and outgoing group 1 and then save the settings to the gateway using the Save to gateway button 14 In the GSM outgoing groups GSM group 1 section set the following parameters a ...

Страница 68: ...Quick Step by Step Manual 3 2 68 1 Fully configure the enhanced CPU see Section 3 5 2 Activate the SIM Client process in the enhanced CPU web interface management windows ...

Страница 69: ...U The enhanced CPU see Subs 2 1 Enhanced CPU Board gives the gateway new advanced features and a web interface This unit has extra firmware which can be upgraded via the web interface in the Management Firmware section The eCPU firmware files are in the PGW 0 X XX format XX stands for the version number Please keep in mind that the typical size of the eCPU firmware is about 10MB It is important fo...

Страница 70: ...or the MS Windows XP SP2 EN OS with the normal text size Program Running Once the installation is complete run the program by clicking on the PRIGW program in your PC menu or on the icon on your desktop or by starting the PRI program exe file which can be found on the appropriate location installed by you using a file explorer commander or browser Having started the program you can use the main me...

Страница 71: ...8 key or use the Gateway Connect gateway menu After a successful connection the program will ask you for automatic downloading of the configuration file from the connected gateway Tip Click on the on line configuration item in the Gateway control section to make the configuration tool automatically try to establish connection with the gateway according to the selected connection type If you are se...

Страница 72: ... this menu to work with the gateway configuration default unnamed ini file or default configuration file i e load save etc The menu contains a program closing item too Load loads the last saved configuration file from the configuration tool directory Or requires loading of default settings upon the first run Save saves the current settings into the file in the configuration tool directory or into ...

Страница 73: ... disconnects the gateway and discontinues its communication with your PC If you communicate with more gateways than one you are advised to have each configuration file in a different directory to avoid unintentional rewriting of the configuration file by another gateway configuration To do this use the Gateway list item Gateway List Select gateway from list select a gateway directory with the conf...

Страница 74: ...wireless engine GSM UMTS board the PRI boards and also the VoIP board The GSM UMTS boards also provide buttons for on line direct control of the selected wireless engine e g restart block etc A similar restart operation can be made with the defined plug in board Tip The Sleep button on the GSM UMTS boards is designed for an easy SIM card exchange under heavy call traffic If this function is activa...

Страница 75: ...Configuration Tool 3 4 75 ...

Страница 76: ...ngine is not registered but is searching for a new provider 3 The wireless engine registration was denied by the network 4 The unknown reason 5 The wireless engine is registered to a roaming network BBB LAC Location Area Code first byte in DEC format CCC LAC second byte in DEC format DDDDD cell identification code Note Registration to a roaming network is restricted by default For roaming enable r...

Страница 77: ...ts into a mode where it will be unable to receive any incoming or incoming call Down button for automatic blocking of a module after the call end Reset button for manual restarting of a selected wireless engine Clear credit button for clearing of call statistics of a selected wireless engine On button for power on of a blocked wireless engine Info on Current Calls This window provides information ...

Страница 78: ...etails see Subs 2 1 Enhanced CPU Board Tracing The window helps save debug traces about the complete statuses of the connected gateway With this tracing you can see the complete ISDN VoIP and GSM signalling messages and active calls Note Tracing can be activated only for one session at a time The other sessions receive a BUSY message if requesting for tracing The debug trace is on line generated f...

Страница 79: ...nal Strength of the BCCH carrier from 0 to 63 The indicated value is composed of the measured value in dBm plus an offset This is in accordance with the formula specified in 3GPP TS05 08 dBm Receiving level of the BCCH carrier in dBm PLMN PLMN ID code LAC Location Area Code HEX Cell Cell ID code HEX NCC PLMN colour mode BCC Base station colour mode PWR Maximum power level used on RACH channel in d...

Страница 80: ...ain system CPU see Subs 2 1 Basic CPU Board used for upgrading the P2005 V 02 XX XX files XX stands for the version number You can upgrade this CPU locally via an RS232 or remotely via the TCP IP For the upgrading procedure refer to Subs 2 4 Basic CPU Firmware Find the latest firmware version in the status line of the connected configuration tool or via the eCPU web interface PRI Gateway section V...

Страница 81: ... firmware upload to avoid gateway malfunction For the latest firmware version see our websites www 2n cz Time and Date With this window you can change the current time and date of the basic CPU Note The enhanced CPU must be synchronised from the basic CPU or a public NTP server If you use 2N SIM Star 2N SIM Star Server will automatically synchronise all the connected gateways according to the basi...

Страница 82: ...oice messages can be uploaded only locally via a serial port directly to the AUX board Before uploading a voice message switch on the AUX board mode refer to Subs 2 1 AUX Board You can use the following types of voice messages Type of message Use Maximum length sec DISA message Incoming calls from GSM UMTS 64 Connection message 1 Outgoing calls via GSM group 1 8 Connection message 2 Outgoing calls...

Страница 83: ...ttached headset connected to the AUX board you can generate outgoing calls to the PRI VoIP or GSM UMTS interface It is also possible to connect an incoming call from a defined interface to the analogue interface The gateway will automatically generate debug traces in the case of active test call This debug information can automatically be saved to a text file for later retrieval ...

Страница 84: ...rface at a transmission rate of 57 600bps LAN communication The configuration tool will try to establish the gateway connection via the TCP IP Telnet protocol In the case of normal connection you will be requested for the IP address IP port username and password of the remote gateway To connect with a gateway from the Gateway list the configuration tool will use saved connection parameters Modem A...

Страница 85: ...ction The items in this section are indicated by variable icons informing you of the available configuration possibilities gateway disconnected no possibility to change on line parameters gateway connected you can change on line parameters The off line configuration parameters can be set and saved into the cfg file These parameters are described below Reset commands are items responsible for the r...

Страница 86: ...e configuration status line provides basic information on the gateway connected Configuration All configuration windows contain the following buttons for you to load save configuration from to the connected gateway or configuration file Save to gate Upload all parameters of the selected configuration window to the gateway Load from gate Download all parameters of the selected configuration window ...

Страница 87: ... and VoIP card IP mask IP router IP address of the network gateway to be used by the basic CPU and VoIP card Init sequence for modem An AT command sent by the gateway via COM2 upon detecting a connected analogue or BRI ISDN modem This parameter must be in the format of the AT command that is compatible with the connected equipment Saving call data CDR A way of saving the Call Data Records into the...

Страница 88: ...tgoing GSM group setting Number for remote control PRI 1 PRI 2 The remote control number for a date call via the B channel of the ISDN PRI 1 or PRI 2 interfaces this feature is optional for details refer to Subs 2 1 PRI Board Automatic log out of GSM modules This function is used for automatic log out of wireless modules from the wireless network in a selected time interval If the logged in module...

Страница 89: ... use the standard IP port values which are reserved for other well known TCP IP services Examples of common services and assigned IP ports Service IP port number http 80 ftp 20 21 Telnet 23 SSH 22 SMTP 25 161 162 366 NTP 123 DNS 53 BOOTP 67 68 TFTP 69 POP 109 110 SFTP 115 IMAP 143 220 LDAP 389 HTTPS 443 This is for orientation only For a complete list refer to the Well known ports on the Internet ...

Страница 90: ...he standard call SIP signalling process in the case of VoIP to GSM UMTS call o Send 180 the gateway will send message 180 instead of 183 o Send 200 OK the gateway will send message 200 OK instead of the above messages 180 183 o Send 200 Bye the gateway will add message 200 Bye before a rejected call Voice parameters Use these parameters to define the range of the IP ports for RTP streams The ...

Страница 91: ...the VoIP cards The STUN server is required in case your public IP connection has no fixed IP address o Next STUN server request time period between two requests for public IP information The gateway will also send request after every system restart Note The default IP port for SIP signalling is 5060 The RTP range is 8000 8998 The STUN port is 3478 In case the gateway is behind the NAT you have to ...

Страница 92: ... Deactivated G 729 2 Deactivated G 723 2 Deactivated G 723 bitrate is 6 3 kbps Caution Using low rate codecs may deteriorate voice quality You have to have a wide band TCP IP connection for using a high rate codec You can use an Internet VoIP bandwidth calculator to calculate the actually required bandwidth e g www bandcalc com ISDN Parameters This window allows you to set all parameters related t...

Страница 93: ...Configuration Tool 3 4 93 ISDN PRI 1 PRI 2 Set the main configuration of the PRI 1 PRI 2 ISDN interfaces located on the PRI card o ISDN PRI port type here define the PRI 1 2 ISDN port type ...

Страница 94: ...ue is 0 CRC Enable disable receiving CRC on Layer 1 on the ISDN PRI interfaces in both modes the gateway sends the CRC Assignment of GSM channel Define the way of using GSM UMTS engines as assigned in the Outgoing GSM group for outgoing calls o Cyclical the gateway routes outgoing calls according to the LCR settings to the defined outgoing GSM group The wireless engines assigned to the used outgoi...

Страница 95: ...jects the incoming call that does not meet the required number length see the GSM basic parameter for right settings The default value is 102 o Restricted number prefix rejects the incoming call whose prefix does not match any of the prefixes defined in the Prefixes The default value is 21 o Selected module GSM group is not ready rejects the incoming call because no free wireless engine has been f...

Страница 96: ...vice unavailable 55 Incoming class barred within CVG 603 Decline 57 Bearer capability not authorised 501 Not implemented 58 Bearer cap unavailable at present 501 Not implemented 63 Service or option unavailable 503 Service unavailable 65 Bearer cap not implemented 501 Not implemented 79 Service or option not implemented 501 Not implemented 87 User not member of CVG 603 Decline 88 Incompatible dest...

Страница 97: ...ic feature designed for the Hungarian national dialling plan The gateway activates a specific dialtone for second dialling after receiving two digits Do not send CONNECT_ACK on TE When the ISDN PRI is in the TE mode the gateway will not send the CONNECT_ACK message Tone signalling National settings of dialling and ringing tones You can enable the busy tone in the case of call reject Numbering plan...

Страница 98: ...ode After the timeout the dialled number will be automatically sent to the wireless network Call delay Define the minimum timeout between the end of a call and the beginning of another outgoing call for one wireless engine The default value is two seconds Unless absolutely necessary do not change the default value to avoid system instability Holiday list Define the days on which the gateway will a...

Страница 99: ...iemens wireless engines This serial number is used for the CDR and diagnostics Disable CLIP from GSM to ISDN Disable CLIP transfer from wireless networks to the ISDN VoIP interfaces Text of SMS at no answer Type the text for automatics SMS messages sent in the case of unanswered outgoing calls see the GSM Outgoing Groups below If string n is used the gateway replaces it with the Calling party numb...

Страница 100: ... and outgoing call routing rules are used for outgoing and incoming groups of wireless engines GSM Outgoing Groups This window allows you to set parameters related to outgoing calls to wireless networks and the SIM card using time Mode of switching SIM card Define how the SIM cards should be used in the selected GSM group ...

Страница 101: ...tions to be checked for SIM by the gateway after the GSM UMTS board start restart The SIM card holders that were not tested have the undef status in the diagnostics window of the configuration tool Disconnect call Set the rules for automatic disconnection of outgoing calls to a wireless network o SIM limit exceeded automatic call disconnection when the active SIM card call limit is exceeded o Swit...

Страница 102: ... active o 2 the Alerting message will be automatically sent after a predefined number of seconds after the call is dialled into wireless network Default delay for SMS at no answer Set the minimum time for a call in the alerting state for automatic sending of a defined SMS text in the case of unanswered outgoing call Note For successful SMS sending the Alerting message to the ISDN interface ringing...

Страница 103: ... XX001 Roaming is permitted for network with MCC MNC codes 00001 99001 XXXXX Roaming is permitted for any network Note Before activating the roaming support please check the SIM card for correct setting of the GSM UMTS priority network list Caution Calls via roaming networks may cause additional call costs CLIR Use the parameter to enable disable the CLIR and CLIP functions for outgoing calls via ...

Страница 104: ...parameter is set to seconds Example 2 Calls are charged for the first minute and then second by second Settings The First count parameter is set to 60 the Next count parameter to 1 The Call length counting parameter is set to seconds A proper setting of these parameters helps you keep a realistic record of the minutes spent and charged for each SIM card These parameters are used for limit counters...

Страница 105: ...ncoming calls voice message all incoming calls are routed to PRI 1 VoIP If the Timeout parameter is greater than 0 seconds the calling party hears the DISA message for DTMF dial in o Receive incoming calls dial tone all incoming calls are routed to PRI 1 VoIP If the Timeout parameter is greater than 0 seconds the calling party hears the defined dial tone for DTMF dial in o After ring call back ref...

Страница 106: ...ially in the case of unavailability or busy if no DTMF dialling DISA is made Prefix before DISA preselection The prefix the gateway adds before the DTMF dial in For example the received DTMF digits are 487 and this prefix is 6655 The gateway will send number 6655487 to the ISDN PRI interface CLIP Here you can change the incoming CLIPs from wireless networks The default format of the incoming CLIP ...

Страница 107: ...aution The automatic dial in function is the wireless provider s service Before activating this function please ask your provider for additional information Direct routing With this table you can assign a unique called party number extension to each GSM UMTS module Prefixes This window allows you to set the call prefixes related to the LCR table The gateway can contain up to eight prefix and prefi...

Страница 108: ...le For a call the gateway checks the lines and if the called number prefix matches the prefix in the selected network list and the current time value is within time limitation limits the call will be routed via the defined GSM group s or PRI 2 interface Network ID The used prefix list number value of the GSM network ID from the selected prefix list Groups Used destinations of outgoing GSM groups f...

Страница 109: ... CLIP CLIP of the incoming calling party that should use the CLIP routing or CallBack functions Dial Number of the internal extension SIP line in the case of activated CLIP routing Limit The maximum length of an active outgoing call 0 unlimited call length Autodial Use the parameter to activate the CLIP routing function for a selected CLIP Auto CallBack Use the parameter to activate the CallBack f...

Страница 110: ...e sent are terminated Note Restart of the gateway will cause disconnection of all proceeding calls Factory Reset Resets the connected gateway selecting the factory settings for the gateway Caution Using this function you erase all settings except for the IP setting and access username and password Restart of the gateway will cause disconnection of all proceeding calls ...

Страница 111: ... simulator SNMP remote control Caution Some features can be limited by the licence file For detailed information on the current licence state see Subs 2 4 Licence Limitations For factory settings of the eCPU refer to Subs 3 1 It is possible to change the basic IP settings locally via a serial console For description of the serial console configuration see below Serial Console Access The console sy...

Страница 112: ... Below is a brief survey of these menus only Main menu This menu appears after the serial cable is connected to the eCPU sometimes you must press Enter The main menu contains the following items Configuration menu Use this menu to configure the Ethernet interface and serial console o Network contains eCPU Ethernet interface settings Set the static IP address or activate the DHCP service support Yo...

Страница 113: ...anufacturer supplies the gateways with a predefined default user account Admin without having set its default password Mind the Upper Lower Case while entering the user name and password The first thing you should do for safety reasons after putting your gateway in operation is to change the administrator password Web Administration Login Page After a successful login you get onto the main page of...

Страница 114: ...inactivity or upon the web browser closing Note Remember to type the Serial number and StarGate serial number while requesting for a new licence type Icons The web interface uses the icons located on the bottom of the configuration page The table below describes these icons Save settings Reset settings ...

Страница 115: ...e selected item s Add item Refresh item Save to local disk Messaging This section contains settings for sending receiving SMS via the POP SMTP protocols The main menu is divided into eight SMS delivery groups which correspond with the GSM outgoing groups in the basic CPU settings see 3 4 GSM Outgoing Groups ...

Страница 116: ...user o Deliver SMS to user select the users for the VIP numbers table and incoming SMS with no record in the SMS Auto Clip Routing table For how to manage the users see Subs Management Automatic answer delivering A parameter for SMS Auto Clip Routing which defines the maximum delay between the SMS sending and SMS answering from one and the same GSM number SMTP POP3 server settings Parameters for S...

Страница 117: ...the 16 bit format for SMS Allow SMS concatenating Enable disable division of an SMS longer than 160 chars Insert email sender to SMS Insert email subject to SMS Caution The format of the authorisation username requested by your e mail client is user_name email_domain_name VIP Numbers A table of numbers CLIPs of SMS senders for a selected SMS delivery group This table is designed for fixed routing ...

Страница 118: ...nterface the e mail header and subject of the message are filled in according to the CPU settings An already read message can be deleted from the POP3 server You can delete a message from the gateway eCPU or mark it as already read but the POP3 server cannot see it The server awaits e mail in the format Text Plain Text HTML Multipart Mixed or Multipart Alternative From a message in the Text HTML f...

Страница 119: ...ion A complete configuration of the gateway Reset Items for the gateway remote restart and restart with factory setting restoration Configuration back up Option to download the current basic CPU configuration Tip All the configuration features are similar to those used in the configuration tool Before using the web interface please read Subs 3 4 carefully Gateway Control Firmware Licence A section...

Страница 120: ...nloading LOG messages from the basic CPU Statistics Provides the current state of call statistics of the gateway Actual calls info The current state of active calls through the gateway Connection state The current state of all local remote configuration sessions Dynamic CLIP routing table The current state of the Auto Clip Routing table SIM card statistics The current state of call limits of the S...

Страница 121: ...M Client It is a functional part of the 2N SIM Star system This process is designed for translation of data streams of remote SIM cards to GSM modules and vice versa Information Information on the SIM Client software version upgrade is possible as part of the eCPU firmware Channels The current state of all wireless channels connected to 2N SIM Star Settings Settings of the username password and IP...

Страница 122: ... your call bill real calls and SMS It is necessary for you to know the phone numbers and IMSI of the SIM card used for a correct function of the Call SMS simulators There are two ways of importing these numbers to the system Using local IMSI Phone list Prepare a CSV file divided by space for data importing with all the required SIM card data 230013001547875 731123446 230014120587987 605123446 Usin...

Страница 123: ...cted calls between two modules Module choice method A way of using wireless engines for calls o Cyclical wraparound using of defined wireless engines o Random random use of defined wireless engines Calling called module range A group of wireless engines to be used for the Call simulator SMS simulation Delay between messages Time in minutes between two automatic SMS You can choose Hard every define...

Страница 124: ...status screen for all the above mentioned functions and additional eCPU configuration The window is divided into four sections Licence Information on the current licence state and potential licence expiration Times The current system time and up time of the eCPU System status States of all eCPU functions You can enable disable each function manually Caution You have to activate the requested funct...

Страница 125: ...ur websites www 2n cz Time The eCPU does not contain a clock generator of its own It is necessary to synchronise it from any place You can choose an NTP server or the basic CPU of the gateway LOGs Here you can set and download the eCPU status log records Configuration back up An option to download the complete eCPU settings Restart Reboot of the eCPU You are recommended to use this function instea...

Страница 126: ...SMS delivery groups 1 8 Tip If you forget the Admin user password you can restart the gateway with restoring the factory settings using a serial console Service account Description Admin Account for configuration eCPU simstar Account for SIM Client sms Default user for SMS and SMS simulator The default accounts are added by the default settings one per User group Click on the Add user icon to add ...

Страница 127: ...er RAM 2048 MB RAM HDD 60GB SATA CDROM Only CD R LAN Ethernet 100BaseT Installation Procedure Caution By using the installation CD you remove ALL data from the hard drive This installation is automatic and requires a very low user interaction Follow the instructions below to install a perfectly working system Set your PC to use the CD ROM as the default boot device Place the installation CD into t...

Страница 128: ... OK to test the CD or Skip to continue the installation process The installer will automatically format the hard drive and install all system files When the installation is finished the installer will wait for reboot confirmation Press ENTER to continue Remove the CD from the CD ROM and let the new system boot ...

Страница 129: ...TP protocol and so you need the Internet connection Package Installation Choose the package to be installed You can choose either the 2N ERM or 2N SIM Star Server application Configuration Licence The ERM licence is per gateway connection The licence is generated by the 2N Technical Support and based on the gateway serial number For a correct function copy the licence file into the etc erm directo...

Страница 130: ...lnet protocol default 2n Password String Password for gateway access through Telnet protocol default 2n Inc_table inc001 to inc100 Name of the table that includes record for incoming GSM call filtering One table may be shared by multiple GSM gateways Inc_table_enabled True or False Enables True or disables False filtering of incoming calls Other_CLIP 0 or 1 Determines whether an identified GSM CLI...

Страница 131: ...Status Writes out the ermserver service status i e whether or not it is running import db_name CSV_file replace_duplicates Imports a new record into database table db_name name of the database table to be used for import CSV_file name of the CSV file to be used for import If the file is unavailable in the current directory the full path has to be listed The CSV file values are separated with a com...

Страница 132: ...ormation on any new call to the ERM and awaits reply with call instructions within 2 seconds If no reply comes from the ERM within this timeout the call is routed according to the internal routing tables The functional diagram below shows the request processing procedure ERM Database Structure As mentioned in the ERM Control subsection above a csv file with a specific structure has to be used for ...

Страница 133: ...ay Define a day in the week on which the rule shall be applied 1 Monday 7 Sunday Structure of out_table This table is used for identification of the subgroup from which the call is coming The search result is used for search in the clip_table CGP Company Time from Time to Day 261301___ 1 00 00 12 00 1234567 2353215__ 2 12 00 24 00 1234567 261333111 100 00 00 24 00 1234567 261333222 101 00 00 24 00...

Страница 134: ...s checked from the left Company Use this parameter to define to which subgroup the rule is to be applied Change prefix Use this parameter to modify the number to be dialled The character removes one character from the left side of the called number The other characters are added to the called number beginning Delete last Use this parameter to remove characters from the right hand side of the calle...

Страница 135: ...ned for up to 18 SIM boards The SIM box works as a traditional Ethernet switch that provides comfortable connection and storage of SIM boards 2N SIM Star Server a rack mounted PC that provides seamless integration of the system and allocates the GSM UMTS module SIM cards according to the user defined rules 2N SIM Star Server includes a web interface for easy and user friendly system configuration ...

Страница 136: ...he gateway After a few seconds an unanswered call is hung up 2 The gateway sends the user authorisation request to the VCC 3 The VCC authorises the calling party 4 The gateway starts calling back to the calling party and waits for call connection 5 The calling party receives a voice message for DTMF dial in and the dial destination called party number 6 The gateway sends the destination authorisat...

Страница 137: ...o a defined interface Telnet RS232 2N XAPI Server Configuration The installation file setup exe is located on the installation CD After successful installation start 2N XAPI Server The first thing you should do is establish connection between your 2N StarGate BlueStar BlueTower gateway and the PC where 2N XAPI Server is installed Close all windows except for the main 2N XAPI Server window In main ...

Страница 138: ...nal status of the GSM modules in the 2N XAPI Server status window 2N XAPI Server Licences To activate the Voice CallBack Centre enter the valid licence code into 2N XAPI Server This licence is generated by 2N according to the requested service and the basic CPU serial number in the connected gateway The licence contains two codes to be entered For how to add a new licence see the figure below ...

Страница 139: ...onnected the gateway you will not succeed in adding a licence to 2N XAPI Server getting the BAD LICENCE response The user creating procedure is very similar to the licence adding one Please follow the figures below Click on the USER icon to open the window with all active users In the USER window click on the second icon from the left and then on the icon for a new user ...

Страница 140: ...ck Centre software successfully set communication with 2N XAPI Server As shown in the figure below set the username and password the same user account as in 2N XAPI Server and the IP address of the PC where 2N XAPI Server is running In case 2N XAPI Server is running on the same PC add the local host IP address 127 0 0 1 Once 2N XAPI Server is correctly configured and access parameters are properly...

Страница 141: ...each user a credit amount tariff for each group destination Automatic credit restoring can be activated deactivated in the setting window If you are adding a lot of new users you can use tariff templates which may be assigned to a new user These templates are defined in the Tariff templates window As shown in the example above user Pavel has a phone number 420605215677 and credit rights for destin...

Страница 142: ...fined in these tables are rejected Prefixes to GSM Currently not used please do not change this table Prefixes to ISDN Currently not used please do not change this table Settings Before using the Voice CallBack software set the X10 parameter in the gateway as follows Open the management software e g PRIGW program Establish connection with the gateway over a serial interface or TCP IP Open Terminal...

Страница 143: ...and statistics generated by the 2N StarGate BlueStar BlueTower gateway A guide to the advanced gateway configuration using AT commands is also available Here is what you can find in this section List of AT Commands List of Status Codes Trace List of LOG Events Statistics CDR Line Description ...

Страница 144: ... of statistics of SIM card of GSM module AT T ALL mi ci si mo co so Settings of statistics of all SIM cards of GSM module AT TALL ALL mi ci si mo co so Settings of statistics of all SIM cards of all GSM modules Description of parameters Mi mo Minutes of incom outg calls Ci co number of connected incom outg calls Ri ro number of re routed incom outg calls in group Si so number of received sent SMS ...

Страница 145: ...ming outgoing calls Y to each call add NET info 1 or no 0 AT S93 x Global selection of SIM card 0 according to GSM group 1 8 number of SIM holder AT S98 xxxx PIN code for SIM cards inserted in the gateway AT S99 dd mm yy w hh mm ss Gateway date and time settings AT X00 hout hin min Automatic logout of GSM modules hout hour when the modules start to log out randomly hin hour when the modules start ...

Страница 146: ...er atms atfs transit receive gain 3 5dBm 1 2 5dB 0 0dB 2 2 5dB 4 5dB AT G06 mmdd mmdd List of holiday days mm month dd day max length of line is 63 chars AT G07 mmdd mmdd Net list of holiday days AT G08 delay min max tout Parameters of dialling from ISDN to GSM delay relax delay between calls min minimum length of number dialled from ISDN max maximum length of number dialled from ISDN tout delay b...

Страница 147: ...from ISDN LCR Table AT R Shows LCR table AT R net hh mm hh mm w gr Settings of line 0 63 of LCR table net number of network list 0 8 hh mm hh mm w line using time limitation gr GSM group numbers Test Calls AT SPxx dial Initiates testing call from AUX interface xx is the called interface 1 15 17 31 B channel 32 rotating B channel AT SGxx dial Initiates testing call from AUX interface xx is the call...

Страница 148: ...ion number of SMS smspdu ch ix sts len pdu csum Content of SMS message len length of SMS message number of bytes in PDU PDU content of message in PDU format csum checksum of all PDU bytes 2 hexa digits calculated without carry smsdel ch ix SMS message deletion confirmation smserr ch id ix req err cms Fault command response or SMS not sent req required wireless engine or GSM group err error code 6 ...

Страница 149: ...List of AT Commands 4 1 149 Huawei 1 SM 2 SM 3 SM SierraWir 1 SM 2 ME 3 SR Motorola 1 IM 2 IM 3 IM ...

Страница 150: ...RESET command DETECT OK Rest status HW is working on board full operation DISC UNDEF Empty slot DETECT CHECK Board firmware check AUX only ERASE ERASE Board firmware erasing AUX only PROF PROG New board firmware loading AUX only OK DETECT New board plug in detected INIT DOWN Frozen status HW is working on board but no new calls are started board reset MODEM0 Parameter S80 sent to modem AUX only MO...

Страница 151: ... Call Received Call to PRI ringing Call from PRI ringing CONREQ Connect Request Call to PRI answered Call from PRI answered IPROC Incoming Call Proceeding Dialling to PRI terminated Dialling from PRI terminated ACTIVE Active Connected call DISREQ Disconnect Request End of call from PRI End of call to PRI DISIND Disconnect Indication End of call to PRI End of call from PRI RELREQ Release Request Ch...

Страница 152: ...d next attempt in 2 10 minutes Mod err Defective or unconnected GSM module next attempt in 2 minutes Pin err Wrong PIN permanently in BLOCK status Sim err Defective or non inserted SIM card next attempt in 2 minutes Log out Temporarily logged out according to parameter X00 Puk req SIM card requires PUK undef This position of SIM card was not checked by gateway GSM Layer 3 Name Description NULL Res...

Страница 153: ... LOGFILE Content of log file is being written out CALLFILE Content of call file is being written out CALLREAD Call file records are read AUTOFILE Content of incoming call auto routing chart is being written out QUERY not used so far SCREEN not used so far MATRIX Active matrix screensaver FUNCFILE Content of debug file is being written out LCRFILE not used so far Telnet Layer Name Description LOGOU...

Страница 154: ...er 1 error ISDN1 L2 ERR PRI port layer 2 error ISDN2 L3 ERR PRI port layer 3 error ISDN3 G2 ERR GSM module layer 2 error gate2 G3 ERR GSM module layer 3 error gate3 C4 ERR Link layer error call4 Record Type in Call File Name Description I FD Unconnected incoming call attempt I OK Connected incoming call O FD Unconnected outgoing call attempt O OK Connected outgoing call ...

Страница 155: ...message directed from a lower layer process to a higher layer process request response The message type layer 3 messages are shifted by a space to the right layer 4 messages by two spaces to the right and the message content follow ISDN Messages Typically Used ISDN Messages Q 931 alertin Alerting callproc Call proceeding progress Progress setup Setup connect Connect setack Setup acknowledge connac...

Страница 156: ...nel not available 65 Nobearer Bearer capability not implemented 81 Callref Invalid call reference value 88 Dest Incompatible destination 96 Elemmiss Mandatory information element is missing 97 Message Message type non existent or unimplemented 99 Element Information element parameter non existent or unimplemented 100 Elemerror Invalid information element contents 101 Incmess Message incompatible w...

Страница 157: ...ial controller on GSM board Hscx RD WR Error in initialisation of HDLC controller on AUX board Pri RD WR Error in initialisation of PRI controller SYSERR User stack error SW error stock integrity failure BRDIN 08 TYP STS Board inserted number of gsm board type status BRDOUT 08 TYP STS Board disconnected BRDRES 08 TYP STS Reset the board by AT command ALL GSM RESET CMD Reset all GSM boards by AT co...

Страница 158: ... packet L3 ERR tout sts p Error of isdn layer 3 timeout in status on channel p G2 ERR ATD ERROR init g Error of isdn layer 2 restart of module g after rejected command ATD by GSM network GSM Cause 150 g Error of isdn layer 2 restart of module g after cause 150 was received call barred by GSM network G3 ERR tout sts g Error of isdn layer 3 timeout in status on module g C4 ERR tout sts p g Error of ...

Страница 159: ...6 37 10 0 04 05 02 14 0 14 15 7 0 5 0 05 31 3 0 06 07 03 4 0 04 21 3 0 0 0 00 00 0 0 08 09 04 0 0 00 00 0 0 0 0 00 00 0 0 10 11 05 0 0 00 00 0 0 0 0 00 00 0 0 12 13 06 0 0 00 00 0 0 0 0 00 00 0 0 each line is for two wireless modules Statistic of calls on GSM module 0 sim dir net grp minutes hhhh mm ss calls reject failed c offs sms 1 inc 1 14 0 14 15 7 0 2 9 0 2 inc 1 0 0 00 00 0 0 0 0 0 3 inc 1 ...

Страница 160: ...E sent to ISDN Column 5 number of used B channel number of used GSM module Column 6 used GSM group C CallBack to PRI 1 E call via PRI 2 interface Column 7 call setup time Column 8 call duration in mmm ss max 255 59 or error cause for unconnected calls Column 9 call cost will be implemented in a higher firmware version Column 10 gateway id optional Column 11 called number Column 12 calling number C...

Страница 161: ...5 Technical Parameters This section provides technical conditions for the 2N StarGate BlueStar BlueTower installation StarGate Technical Parameters BlueStar Technical Parameters BlueTower Technical Parameters ...

Страница 162: ......

Страница 163: ...M boards with TC35i MC55i Q55 UMTS boards with MC8790V module connector SMA 50ohm Antenna splitter Only external models PRI Interface s Interface 1PRI or 2ISDN PRI Frame E1 CRC Supported Signalling Q 931 EDSS1 Type NT or TE Switchable NT or TE TEI number 0 63 Clock master or slave Master Slave Connector RJ 45 Rxpin Txpin Switchable RJ45 Rx 3 6 Tx 4 5 Rx 4 5 Tx 3 6 D channel timeslot 30 VoIP interf...

Страница 164: ...ing temperature range 0 C to 40 C Relative humidity max 95 at 40 C Air condition Recommended Remote Control Line Types Type of line Serial line COM1 2 Analogue modem COM2 ISDN modem COM2 Ethernet 10baseT Telnet ISDN PRI PRI 1 PRI 2 Web interface HTTP eCPU ...

Страница 165: ...M boards with TC35i MC55i Q55 UMTS boards with MC8790V module connector SMA 50ohm Antenna splitter Internal 16 1 or 16 2 PRI Interface s Interface 1PRI or 2ISDN PRI Frame E1 CRC Supported Signalling Q 931 EDSS1 Type NT or TE Switchable NT or TE TEI number 0 63 Clock master or slave Master Slave Connector RJ 45 Rxpin Txpin Switchable RJ45 Rx 3 6 Tx 4 5 Rx 4 5 Tx 3 6 D channel timeslot 16 VoIP inter...

Страница 166: ...ing temperature range 0 C to 40 C Relative humidity max 95 at 40 C Air condition Recommended Remote Control Line Types Type of line Serial line COM1 2 Analogue modem COM2 ISDN modem COM2 Ethernet 10baseT Telnet ISDN PRI PRI 1 PRI 2 Web interface HTTP eCPU ...

Страница 167: ...boards with TC35i MC55i Q55 UMTS boards with MC8790V module connector SMA 50ohm Antenna splitter Only external PRI Interface s Interface 1PRI or 2ISDN PRI Frame E1 CRC Supported Signalling Q 931 EDSS1 Type NT or TE Switchable NT or TE TEI number 0 63 Clock master or slave Master Slave Connector RJ 45 Rxpin Txpin Switchable RJ45 Rx 3 6 Tx 4 5 Rx 4 5 Tx 3 6 D channel timeslot 16 VoIP interface Inter...

Страница 168: ...king temperature range 0 C to 50 C Relative humidity max 95 at 40 C Air condition Recommended Remote Control Line Types Type of line Serial line COM1 2 Analogue modem COM2 ISDN modem COM2 Ethernet 10baseT Telnet ISDN PRI PRI 1 PRI 2 Web interface HTTP eCPU ...

Страница 169: ...ary Information This section provides supplementary information on the product Here is what you can find in this section Regulations and Directives Troubleshooting List of Abbreviations General Instructions and Cautions ...

Страница 170: ...the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment Regulation EC No 1907 2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration Evaluation Authorisation and Restriction ...

Страница 171: ...tain line DspAddr with value not equal to 00 00 00 00 00 00 YES NO Is the gateway mode set to SIP System parameters section YES NO Is the VoIP card MGCP gateway parameter set to correct IP YES NO Is it possible to make calls using your gateway YES NO can be upgraded loaded by the PRI configuration program version 1 1m or higher can be changed with the help of the 2N Technical Support IF YOU SUCCES...

Страница 172: ...st There is no rule in the LCR table connecting this prefix list with at least one GSM outgoing group The call type is not voice FAX DATA The used voice codec is uLaw the gateway supports aLaw only SMS at no answer does not contain the Calling party number The Text of SMS at no answer parameter must contain n which represents the calling party number The Init LED is flashing on the GSM UMTS board ...

Страница 173: ... connection opposite side FXO interface FW Firmware similar to SW a term for the central microprocessor program GSM Group Switched Mobile system the present standard digital mobile telephone network GPRS General Packet Radio Service high speed data transmission for GSM networks HW Hardware an electronic device circuit board component etc in this context P A BX Private Automatic Branch Exchange PC ...

Страница 174: ...d module to be inserted in a GSM device for identification SMS Short Message Service a term for the system and one unit message SW Software TTL Transistor Transistor Logic a standard digital technology defining voltage for levels 0 and 1 PSTN Public Switched Telephone Network ...

Страница 175: ...s a result of a natural disaster or any other unfavourable natural condition The manufacturer shall not be held liable for any damage of the product arising during the shipping thereof The manufacturer shall not make any warrant with regard to data loss or damage The manufacturer shall not be liable and responsible for any direct or indirect damage incurred as a result of a use of the product in c...

Страница 176: ... electric appliances and battery packs removed from them to dedicated dumpsites or containers or give them back to the dealer or manufacturer for environmental friendly disposal The dealer or manufacturer shall take the product back free of charge and without requiring another purchase Make sure that the devices to be disposed of are complete Do not throw battery packs into fire Battery packs may ...

Страница 177: ...2N TELEKOMUNIKACE a s Modřanská 621 143 01 Prague 4 Czech Republic Tel 420 261 301 500 Fax 420 261 301 599 E mail sales 2n cz Web www 2n cz PR 1121 v3 0 ...

Отзывы: