HAA9350 

 

 

DUAL OUTPUT FULL FEATURE 

VANDAL-RESISTANT KEYPAD 

(DK-9350) 

 

 

USER MANUAL 

2

 

 

  

 

 

 

Summary of Contents for HAA9350

Page 1: ...HAA9350 DUAL OUTPUT FULL FEATURE VANDAL RESISTANT KEYPAD DK 9350 USER MANUAL 2...

Page 2: ...ing The Visitor Codes Dele ng User Codes Other Func on Codes Con gura on of Output Modes for Outputs 1 2 False A empt System Lock up or Repor ng Door Forced Open Warning Alarm Output Ac va on Announce...

Page 3: ...ua ng op onal electronic door chime The steel box of the DK 9380 is in the size of ng the gooseneck pedestal moun ng post It is also suitable for surface mount on wall The ush mount version of the DK...

Page 4: ...while N C contact for Fail safe The output contact is programmable for Start Stop toggle mode or mer mode from 1 to 999 seconds See programming Loca on 40 43 for the details 6 7 8 OUTPUT 2 a Standard...

Page 5: ...ly Closed N C input terminal referring to ground With the help of a normally closed magne c door switch the system monitors the posi on of open or closed of the door and will give the following func o...

Page 6: ...ng to ground during the me that the door posi on sensor is open circuit due to door opening Use this output to control the other keypad in an inter lock system to prevent that both doors can be opened...

Page 7: ...ones and signals for opera on status NOTE All Paci er Tones can be enabled or disabled through programming op ons at Loca on 83 The Output Ac va on Beep can be enabled or disabled through programming...

Page 8: ...1 0 to 9 4 to 8 digits 10 User Codes for opera ng Output 2 2 Recording Super User Code User Programming No Default Codes Loca on Entry of Code Con rm Comments 4 to 8 digits Owner s Mul task User Code...

Page 9: ...se code keypad locks during 15 minutes Locking can be released at any me with Super User Code 00 Disappearance of all the above securi es F Door Forced Open Alarm Installer Programming Default Disable...

Page 10: ...econds delay with warning 4 Hold contact 10 seconds delay with warning L Delay Time to Start Door Propped up Warning Installer Programming Default OFF Loca on Delay Time Con rm Comments 0 No propped u...

Page 11: ...program a new master code to replace the exit factory master code Once a new master code is programmed the old master code is replaced Use DAP jumper to set keypad to programming mode if master code...

Page 12: ...se all the current data in memory except the master code and set the keypad back to its default values as like a new unit This may be necessary while the stored data can not be traced or for a new own...

Page 13: ...Chart Sec on C 1 for more informa on See informa on on Loca on 82 concerning digit length in Auto and Manual code entry modes Programming Example 1 Set keypad to programming mode with master code and...

Page 14: ...C 2 for more informa on See informa on on Loca on 82 concerning digit length in Auto and Manual code entry modes Programming Example 1 Set keypad to programming mode with master code and key Taking t...

Page 15: ...ut 1 are all temporarily suspended un l SUPER USER CODE is entered again to release the door holding func on The following func ons are Temporary Suspended Door Auto relock Door Forced Open Warning at...

Page 16: ...xample A Daily User Code is 1 3 5 7 then 3 3 5 7 or 1 3 5 8 may be a good choice for Duress code See Programming Summary Chart Sec on C 3 for more informa on See informa on on Loca on 82 concerning di...

Page 17: ...ours All Visitor Codes will be deleted a er power lost See Programming Summary Chart Sec on C 4 for more informa on See informa on on Loca on 82 concerning digit length of the code in Auto and Manual...

Page 18: ...ed Enter Loca on number and User ID if has and the key a Delete a User Code from ID 01 from Output 1 press Loca on 1 User ID 01 and key b Delete a User Code from ID 1 from Output 2 press Loca on 2 Use...

Page 19: ...equired B Loca on 41 or 51 Start Stop Mode toggle The relay outputs can be programmed to trigger ON start and OFF stop with a user code C Loca on 42 or 52 Start Stop Mode toggle with 2 digit Accelerat...

Page 20: ...be considered as two user codes with one for star ng and the other for stopping the output Owner can give the accelerated code to the sta to start a system for example an alarm system The sta can onl...

Page 21: ...to lock 15 minutes a er 5 successive false a empts using incorrect user codes 3 Exit programming mode by pressing the False A empt System Lock up or Repor ng Loca on 70 A er 10 successive false a emp...

Page 22: ...e reset with a user code for output 1 NOTE The door is forced to open without user code or pressing egress bu on Warning ac ve The door is opened with user code or pressing egress bu on No Warning The...

Page 23: ...l code entry Default User Code Entry Modes Auto or Manual Location 82 Paci er Tones ON OFF Loca on 83 The status LED typically ashes while the keypad is in standby Some people nd it is annoying especi...

Page 24: ...seconds delay and warning beep Press the egress bu on momentary the keypad will beep for 10 seconds before Output 1 ac vates Hold contact for 5 seconds with warning beep Press and hold the egress bu o...

Page 25: ...the keypad will generate propped up warning beeps un l the door is re closed This prompts the authorized users to close a door that was not closed properly This func on requires an op onal Normally Cl...

Page 26: ...only need one user code for each output and execu ng each of the special func ons Once the keypad is in single user mode there is no User ID required for the codes just simply enter the code to each L...

Page 27: ...id within me limit of 1 99 hours Emergency user code for actua ng Output 1 and Duress Output simultaneously to report user under duress Programming Examples for Single User Mode 1 Set keypad to progra...

Page 28: ...C Max Ra ng OUTPUT 2 Normally Closed and Normally Open Dry Contacts 1A 24VDC Max Ra ng Tamper Switch Contact Normally Closed Dry Contact 50mA 24VDC Max Duress Inter lock Key Ac ve Output Ra ng NPN Ope...

Page 29: ...LED lights up in Green during the door lock is open Connec on of the door sensing switch is op onal The keypad will provide the following func ons a er it is equipped on door a Door Auto Re lock b Do...

Page 30: ...O zone for tamperproof and emergency reporting Connect the common ground to link up the keypad and the alarm control panel to achieve the logical functions is necessary Please also see the NOTE state...

Page 31: ...rsa Relay output 2 is independent and has nothing concern with the inter lock system It may be used for other applications such as controlling security systems automatic operators etc Please also see...

Page 32: ...s high enough isolation between high voltage and low voltage to prevent damage of the keypad Only one connection option is recommended Make sure the sink current does not exceed the maximum rating of...

Page 33: ...se the Normally Open N O output contact to shunt a Normally Closed N C protection zone of an alarm system Set output contact to Start Stop Mode Programming Option 51 Use the N O or N C output contact...

Page 34: ...g of 30VDC 1A It is prepared for triggering of a door chime G DOOR BELL DOOR BELL N O ELECTRONIC DOOR CHIME DOOR BELL BUTTON F DOOR BELL The Door Bell terminal is a Normally Open relay contact with th...

Page 35: ...PUT An open collector output is equivalent to a Normally Open N O contact referring to ground similar to a relay contact referring to ground The transistor is normally OFF and its output switches to g...

Page 36: ...lls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process during norma...