background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CSB-10T

Page 1: ......

Page 2: ...ION 2 2 INSTALLATION INSTRUCTIONS 4 3 SPECIFICATIONS 6 4 KEYBOARD LAYOUT 8 5 KEYS AND INDICATORS 9 6 INTERNAL FUNCTIONS 12 7 OPERATING INSTRUCTIONS 14 8 TROUBLESHOOTING 19 9 WARRANTY 23 10 DAILY CARE AND MAINTENANCE 24 ...

Page 3: ...n And please replace the necessary component regularly 5 Crane scale is only suitable for hanging from a mechanical hook e g a crane hook Check whether the used crane hook or the lifting device is suitable for the suspended load 6 Make sure that there are no persons or objects under the load secure Working Area to prevent any possible injury or damage 7 The scale is not suitable for weighing a per...

Page 4: ...he crane scale to transport loads e g traveling crane 11 Never operate the scale in hazardous locations The series design is not explosion proof 12 Any structural alterations should not be made to the scale This will lead to incorrect weighing result to violation of safety regulations and to destruction of the scale 13 Avoid sudden and jerky acceleration or deceleration of the load risk of breakag...

Page 5: ...rol x 1 optional e Additional Power pack x 1 optional Contact your dealer if any item is missing 2 2 SECURING THE SCALE 2 2 1 This unit must be hanged via a strong media e g a wire rope or a metal hook to a firm support that can withstands at least 5 times of scale capacity 2 2 2 Make sure that the crane scale is hanged vertically 2 3 POWERING THE SCALE a This scale is powered by the built in rech...

Page 6: ...put jack is located underneath the back of the scale d Before the first time use charge the rechargeable Power Pack for at least 8 hours consecutively or until the charging indicator turns green e For safety reasons do not share the same mains outlet with other apparatus 2 4 OPTIMAL INSTALLATION REQUIREMENTS For optimal results it is recommended that this product should be installed in a location ...

Page 7: ...20T 20000kg 40000lb 10kg 20lb 300 of R C 73 1kg Power Source By Built in Rechargeable Power Pack and or DC12 15V 500mA or 1A Hook Type Fixed type for CSB models and Wire Rope Stopper Included Tare Range Full Range Zero Range Maximum 2 of Rated Capacity Options Wireless or Cable Remote Control Optional Power Pack 24 Hours Non stop Operation To comply with the law of certain countries the pound unit...

Page 8: ... CSB 3T 211 118 181 183 58 36 50 264 6 5T CSB 5T 211 164 181 188 72 43 60 274 9 5T CSB 7 5T 211 254 181 255 90 48 70 298 13 5T CSB 10T 211 254 181 255 90 48 70 298 13 5T CSB 15T 211 361 181 462 150 88 95 304 35T CSB 20T 211 361 181 462 150 88 95 304 35T A B C D E F G H ...

Page 9: ...8 KEYBOARD LAYOUT CSB ...

Page 10: ...ss this key to switch between measurement units or to convert a weight reading into the other unit of measurement In Metric System Countries this key will be without any function 4 TARE KEY Press this key to tare off the weight of a container or decrease value during function setting 5 ZERO KEY Press this key to set weight to zero or increase value during function setting ...

Page 11: ... will appear ON 8 METRIC INDICATOR When this indicator is on the metric weight unit is being employed 9 POUND INDICATOR When this indicator is on the pound weight unit is being employed This indicator may not be available in certain countries KEYS ON REMOTE CONTROL OPTION 10 ZERO KEY Press this key to set weight to zero max zero range 2 of rated capacity 11 TARE KEY ...

Page 12: ...11 Press this key to tare off the weight of a container 12 MODE KEY Press this key to shift between weight units 13 HOLD KEY Press this key to hold release the current weight being displayed held ...

Page 13: ...andspan value reading 4 Fun 4 Auto power off setting NOTE For dealer and authorized personnel only Inappropriate setting s will cause system failure Contact your dealer for more information or service 6 2 HOW TO ENTER THE REQUIRED FUNCTION MODE a Turn scale off b Press and hold TARE then turn scale on Scale displays Fun 1 c Press TARE until the required function number appears d Press MODE ...

Page 14: ...al operation 6 3 INTERNAL FUNCTIONS DESCRIPTION Fun 1 Contact your dealer for more information Fun 2 To check all display segments work properly Fun 3 Contact your dealer for more information Fun 4 To set Auto Power Off Function Two modes are available Default 4_OFF 0 _OFF Auto Power Off Function is disabled 4 _OFF Scale will automatically turned off after 4 minutes unused ...

Page 15: ...oad vertically 8 2 POWER ON OFF THE SCALE Press ON to turn scale on Press OFF to turn scale off 8 3 ZERO FUNCTION If ZERO INDICATOR does not appear when scale is unloaded press ZERO to reset weight displayed to zero Refer to general specification table for maximum zero range 8 4 TARE FUNCTION 8 4 1 To Tare Off the Weight of a Container Apply a container to hook then press TARE to tare off the weig...

Page 16: ...ng the scale may cause damage to the weight sensor inside It is a good practice to remove all loads from hook when not in use This would prolong the lifetime of weight sensor 8 6 WEIGHING FUNCTION a Before weighing make sure that the Zero Status Sign is on b Press MODE until the required weight unit appears c Apply subject matter to hook and the weight of it is displayed d For best weighing result...

Page 17: ...rt way to reduce the waiting time for stable weighting While the weight is placed on the hook an average weight value will be calculated and held on the display for few seconds depending on the Auto Hold Time Period setting Auto Hold Time Period setting 1 Press HOLD key for about 2 seconds the display will read Hod _0 2 Press the HOLD key to increase the time period for 3 5 8 10 12 15 17 20 sec in...

Page 18: ...sired status Method 2 When unloaded weight 0 press and hold the ON ZERO key for about 2 seconds to set backlight ON OFF 8 11 RECHARGING THE SCALE 8 11 1 When low battery signal appears insert a charged Power Pack or apply the AC adaptor to recharge the inserted Power Pack Failure in doing so may cause irrecoverable damage to the rechargeable Power Pack 8 11 2 Low battery signal is represented by e...

Page 19: ...mote control can attain same control results NOTE All internal function settings can only be operated through scale panel keys b Operation distance from CSB scale to wireless remote control is 10 meters unobstructed c When remote control distance decreases change the battery located inside the wireless remote control d Unique radio frequency is assigned to specified unit Never change DIP switch se...

Page 20: ...r charging time is recommended during first time use ZERO WEIGHT CANNOT BE ATTAINED WHEN TURNED ON CHECK Is the scale hanged vertically ACTION Check and try again CHECK Is any load applied to the hook ACTION Remove all loads from hook Turn scale off and turn on again CHECK Is the scale affected by airflow vibration or RF interference ACTION Place scale away from all disturbances and try again ...

Page 21: ...rloaded ACTION Remove all loads from hook immediately and check again SCALE DOES NOT WEIGH CORRECTLY CHECK Is the correct weight unit being utilized ACTION Select the correct weight unit CHECK Is min weight applied to scale ACTION Refer to General Specifications for recommended min load applied and try again CHECK Is the load lifted vertically ACTION Remove all loads and retry ...

Page 22: ...tact your dealer SCALE TURNED OFF AUTOMATICALLY CHECK Is the AUTO POWER OFF function being utilized ACTION Disable the AUTO POWER OFF function CHECK Is the LOW BATTERY sign on ACTION Insert a charged Power Pack or use AC adaptor WIRELESS REMOTE CONTROL DOES NOT FUNCTION CHECK Is the distance between the scale and the wireless remote control exceeding maximum transmission range ...

Page 23: ...ote control low ACTION Change the battery with a new one CHECK Does the transmission frequency matches with the receiving frequency ACTION Contact your dealer CHECK For CSB models only Is the antenna correctly attached to the scale ACTION Attach the antenna to the scale and try again ...

Page 24: ...efective materials and or workmanship Wear out caused by frequent use is not considered as a result of defective material it highly depends on the frequency and load applied to the scale The warranty will be rendered invalid if upon inspection it is found that the product was abused used in a way for which it was not designed mishandled placed in a hostile environment repaired by unauthorized pers...

Page 25: ...oads from hook before transportation e Clean the scale with a soft and damp cloth if necessary with mild detergent f Do not use any harsh abrasive material violate solvent thinner or alcohol for cleaning g Verify the accuracy of scale periodically Re calibrate the scale when needed NOTE In some countries calibration is restricted to be done by qualified or authorized agent only Contract your deale...

Page 26: ... a change in shape stop the use immediately and send it to an authorized dealer for repairs or for the replacement of the part before resuming usage i Store scale in a dry and cool place j Charge the rechargeable Power Pack once every 3 months when not in use in order to keep the Power Pack functioning properly ...

Page 27: ...26 ...

Reviews: