background image

E) SETTINGS

Press the M button and then switch on the scale. The scale has the following 
user settings in this menu:
1. DUMMY ZERO: The user can enable or disable the DUMMY ZERO display 
with this setting. Select YES or NO depending on whether you want to display 
the dummy zero or not.
2. AUTO ZERO: After dummy zero selection the display will show“A-0   X”. 
Here the user can select the range of the autozero. “A-0   0” means auto 
zero function disabled and the display will show even the first count from the 
zero level. “A-0   3” means the auto zero range is 3d, meaning that the scale 
will auto zero any reading between 0d and 3d at the zero level, to maintain 
the correct zero on the scale.

F) CALIBRATION

External Calibration Setting 
Press the ZERO Button and switch on the scale. The display will show “PASS” 
and then “000000”. Press the ZERO Button. The display will show “CAL”. Press 
the ZERO the display will briefly show “no Load” and then the internal division at 
no load condition. Make sure for the decimal point to stop blinking, and then 
press the ZERO Button. The display will show “LOAD” briefly and then again the 
internal counts. Keep the calibration weight and press the ZERO Button, the 
display will show “000000”. Now enter the value of the calibration weight kept 
using the UP and LEFT Arrow Keys. Finally press the ZERO Button, the display 
will  show  the  calibrated  weight.  If  the  difference  between  this  external 
calibration  and  the  previous  internal  calibration  is  more  than  5%,  the  new 
calibration  will  not  be  stored  and  the  scale  will  pick  up  the  values  /  setting 
according  to  the  old  internal  calibration  only.  If  the  user  feels  that  the  new 
external calibration is correct and still the scale is not accepting it, then the 
correct way to do the calibration will be to do the internal calibration again.

G)  BATTERIES

The  scale  is  capable  of  running  on  rechargeable  battery  or  6  pcs  of  AA  size 
batteries, if the scale is not connected to the mains through the adaptor for any 
reason. The following is recommended to maximize the life of the batteries 

If  the  scale  is  not  used  for  long,  it  is  highly  recommend  to  remove  the 
batteries from the scale, as there are chances that batteries may leak and 
damage the scale beyond repair.

Please charge the battery for at least 20 hours before using for first  time.

The battery automatically gets charging once the scale adaptor is plugged in to 
the mains; hence only make sure that the GREEN LED on the top right side of the 
display is ON.

G) MAINTENANCE
#

 The user should never put weight more than the designed capacity of the scale

#

 When the scale is switched on, whenever the user will put more load than the 

designed capacity of scale, then display will show “-OL-” meaning that the scale is 
overloaded.  Even  if  the  scale  is  no  in  use  and  is  switched  off,  if  load  above  the 
designed capacity of the scale is applied on the weighing pan, by keeping some 
weight, or by hand, or any other means, the scale can be damaged beyond repairs.

#

 Never clean the scale with highly intensive solvents like petrol, thinner or acetone   

etc. the best way to clean the scale is to use a slightly moist cloth, and then use a dry 
cloth to wipe again.

OWNERS MANUAL

SHIPPING SCALES

Owner’s Manual

Shipping  Scales

Cruzer Series

4

1

Version 2.01

Cruzer

Reviews: