background image

Ishida SR-2000a Touch Screen Scale and Printer 

Quick Setup Instructions 

 
 

For those familiar with the Ishida SR-2000a Touch Screen scale, this document may be used as 
a quick reference guide.  Simply refer to the Table of Contents below and go to the appropriate 
page for instructions.  It may also be used as a source of detailed step-by-step instructions to 
setup and configure the scale.   
 
 

I.

 

Check and Update Firmware............................................................................................................... 2

 

II.

 

Clear Memory: Standard and Special ................................................................................................. 4

 

III.

 

Install RF card ..................................................................................................................................... 7

 

IV.

 

Configure IP Address, Subnet Mask, etc. ........................................................................................... 8

 

V.

 

Load i-View Backup File.................................................................................................................... 11

 

VI.

 

Setting Up Label Cassette(s) ............................................................................................................ 13

 

VII.

 

Setting Up Label Specifications ........................................................................................................ 14

 

VIII.

 

Enable Ad (Display) Messages: ........................................................................................................ 16

 

IX.

 

Load PLU File Via ScaleLink Pro ...................................................................................................... 17

 

X.

 

Create Keyboards: Categories, Presets, and Function Keys............................................................ 18

 

A.

 

Importing Key Images into ScaleLink Pro................................................................................... 18

 

B.

 

Assigning Images to Keys .......................................................................................................... 18

 

C.

 

Assigning Category Keys............................................................................................................ 19

 

D.

 

Assigning Function Keys ............................................................................................................ 19

 

XI.

 

Appendix............................................................................................................................................ 21

 

1.

 

Label sizes .................................................................................................................................. 21

 

 
 

Rev 1, September 2006 

1 / 21

 SR-2000a 

Quick 

Setup 

Summary of Contents for SR-2000a

Page 1: ...le I Check and Update Firmware 2 II Clear Memory Standard and Special 4 III Install RF card 7 IV Configure IP Address Subnet Mask etc 8 V Load i View Backup File 11 VI Setting Up Label Cassette s 13 VII Setting Up Label Specifications 14 VIII Enable Ad Display Messages 16 IX Load PLU File Via ScaleLink Pro 17 X Create Keyboards Categories Presets and Function Keys 18 A Importing Key Images into Sc...

Page 2: ...n to the left of CF memory card See Figure 1 5 Insert CF memory card p n 91870 into CF card Adapter p n 91871 See Figure 2 6 Insert Adapter with CF memory card into PCMCIA slot of a notebook computer Note any CF card adaptor may also be used such as an external USB device or CF card slot on a desktop computer 7 Copy Latest Firmware onto CF memory card Extract Unzip firmware files directly onto CF ...

Page 3: ...h Screen Scale and Printer Quick Setup Instructions Figure 1 Scale Firmware CF Memory Card Location Eject Button Figure 2 PCMCIA Card Adapter and Compact Flash CF Memory Card Rev 1 September 2006 3 21 SR 2000a Quick Setup ...

Page 4: ... with an original 1 Meg SR 2000a Note Any SR 2000a with serial number 5031600 or higher has 2 Meg of memory 10 Select MEMORY CLEAR 11 Perform the only the first memory clear SRAM Clear a Press CLEAR Æ press EXECUTE Æ Normal is displayed b Note the memory has decreased from approx 2 Meg to 1 Meg See Screen 2 c Press MENU 12 Reinitialize the memory to full capacity a Enter 495344 press MEMORY DATA M...

Page 5: ...ollow the final step to Initialize this will reset the calibration iii Press MENU two times b Initialize Printer i From Test Menu select PRINTER ADJUSTMENT ii Press EXECUTE MEMORY INITIALIZE red box Æ Normal is displayed See Screen 4 iii Press MENU two times c Set Date Time i Enter Programming Menu ii Enter Date and Time values in formats noted on display iii Press MENU 16 Power OFF Power ON Scree...

Page 6: ...Ishida SR 2000a Touch Screen Scale and Printer Quick Setup Instructions Screen 2 Memory Cleared Screen 3 SRAM Formatted to Max Memory 2 Meg Rev 1 September 2006 6 21 SR 2000a Quick Setup ...

Page 7: ...ccess panel 2 Remove the small PCMCIA card bronze access cover by removing one Phillips screws 3 Insert the Symbol PCMCIA card into the upper slot Slot 2 See Figure 3 Note the RF card can be inserted into either slot but only the lower slot can be used for some special functions 4 Power Scale ON 5 Confirm the green LED on the Symbol RF card begins to flash after 15 seconds Note If the green LED do...

Page 8: ... PLU key 3 Select OPTION SET 4 Select ETHERNET CARD 5 Select RF LAN 6 Set Computer IP Address labeled as Host IP Address in early versions See Screen 5 7 Set Scale IP Address labeled as Target IP Address in early versions 8 Set Subnet Mask Example 255 255 255 0 9 Set Gateway 0 0 0 0 Note If the scale will be on a WAN your customer will provide the Gateway IP Address 10 Press FIX key to save settin...

Page 9: ...r should provide the WEP Encryption key value to be used If this is an initial installation use a unique random key value 17 Use the touch screen to enter the WEP Key value press WEP KEY 0 area Example 40 bit Hex format fd494a69bc 18 Press HEX key to select ASC use ASCII characters for the Network Name 19 Use green button to switch between upper and lower case letters and symbols 20 Enter the Netw...

Page 10: ...Ishida SR 2000a Touch Screen Scale and Printer Quick Setup Instructions Screen 5 Ethernet Setting Data Screen 6 RF Setting Data Rev 1 September 2006 10 21 SR 2000a Quick Setup ...

Page 11: ... 2000a d Enter the scale s IP Address select OK e Add an identifying name to the Link Name field such as Meat 1 f Select OK CLOSE 3 Select the Backup Restore tab 4 Highlight the SR 2000a in the left side window 5 In the Restore box lower right side select SELECT 6 Navigate to the desired backup file select OPEN 7 Select Restore Scale 8 Select Standard Restore or Scale to Scale Copy See Screen 8 9 ...

Page 12: ... and must be set separately Refer to the following sections for details to make these settings Label Cassette settings System menu Label Specification Set settings System menu Advertising Message settings Programming menu Touch screen key images ScaleLink Pro Screen 8 i View Restore File Setup Rev 1 September 2006 12 21 SR 2000a Quick Setup ...

Page 13: ...e end of this document for the label formats included in the SR 2000a demo file 5 Set LABEL SPEC as needed see section VII Setting Up Label Specifications for details 6 Set INDIV W BACK based on department 7 Press PAGE 8 Set MANUAL AUTO based on department 9 Set CONTINUOUS DIE CUT as needed 10 Press PAGE 11 Enable SHOP ADDRESS and FIELD TITLE printing as needed 12 Press PAGE 13 Set OVER LEN FLAG 1...

Page 14: ...ton Supervisor 2 Enter System Menu 495344 Æ PLU key 3 Select LABEL SET 4 For Continuous labels perform the following See Screen 10 a Set Label Spec 02 b Set Label Gap 10 0 mm 5 For 64x47mm labels perform the following See Screen 11 a Set Label Spec 03 b Set Label Gap 2 5 mm c Set Preprint Feed 8 5 mm d Set Back Feed Yes 6 Press MENU MENU and return to Operation mode Screen 10 Label Specification f...

Page 15: ...Ishida SR 2000a Touch Screen Scale and Printer Quick Setup Instructions Screen 11 Label Specification for 64x47mm Label Rev 1 September 2006 15 21 SR 2000a Quick Setup ...

Page 16: ...ess left most blank yellow button 5 Set the Display Method FLASH or SCROLL 6 Set the Display Speed FAST MID or SLOW 7 Set number of times to Repeat for flashing messages 8 Repeat for additional message numbers using the next available yellow button 9 Press MENU MENU and return to Operation mode Note The message text can be edited as needed a Enter the Message number Æ press the SCROLL No button to...

Page 17: ... the Setup Menu select Comms On Line b Select ADD c Select SR 2000a d Enter the scale s IP Address select OK e Add an identifying name to the Link Name field such as Meat 1 f Select OK CLOSE 3 From the Comms Menu select Show Comms Status 4 Verify the SR 2000a Status is Connected 5 Select the Send Receive tab See Screen 13 6 From the Scale drop down menu select the SR 2000a 7 From the Send Receive ...

Page 18: ...es menu select SR 2000a Images 5 Select Add 6 Navigate in Windows as usual to select an image from the library 7 Repeat adding images as needed B Assigning Images to Keys 1 From the Scales menu select Memo SR 2000a Presets 2 If prompted select the desired scale 3 Select a page from the left hand box 4 Double click the desired key 5 Set the Key Size the library contains images for large and mediums...

Page 19: ...ey Page 9 Double click the desired key 10 Set the Key Type as Group 11 In the Key Data drop down menu select the appropriate Category 12 Repeat for additional Preset Key Pages Note Assign only one Group key per Preset Key Page 13 Select SAVE If the keyboard is not saved all changes will be lost D Assigning Function Keys The Function Key page is displayed after a PLU has been selected Function keys...

Page 20: ...2000a Touch Screen Scale and Printer Quick Setup Instructions Screen 14 Sample Category Screen with Categories and PLU Presets Screen 15 Sample Function Key Screen Rev 1 September 2006 20 21 SR 2000a Quick Setup ...

Page 21: ...4x59mm COOL label 23 64mm Continuous with Reduced Safe Handling 24 64x73mm Safe Handling with Logo Revised SR 2000a Demo Program Label Formats continuous strip 2 64x47mm Standard UPC 6 64x145mm Bakery with Nutrition with TransFat landscape 22 64x59mm COOL label 23 64mm Continuous with Reduced Safe Handling 31 64x73mm Safe Handling with Logo 32 64x83mm Safe Handling with Lot No COOL Rev 1 September...

Reviews: